24530 Sperry Dr
Westlake, OH 44145
440-871-3777

Local Reviews

Rated 5.0 out of 5 stars based on 1869 customer reviews

Ac charge

All good

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast, efficient, friendly

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

Jose is the best

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Summer A/C maint was very good

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome

Very friendly and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Very thorough.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service was great

This was a pre-scheduled AC check-up. I appreciated the reminder email and the text announcing the technicians name and arrival time. The technician was professional and completed the check-up. He gave me a summary at the end. No problems at all. I have used Bay Furnace for years and recommend their product and service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

TJ G.

TJ G. Job Checkin

Cycled system from tstat, all within spec Humidifier was disabled by homeowner. Checked filter, did not need changed Flushed condensation drain Inspected outdoor unit and capacitor, all within spec Washed outdoor unit.


Besham B.

Besham B. Job Checkin

Check thermostat change filter customer supply flush condensate drain check blower motor. Check disconnect two 30 amp fuse. Check capacitor 45+5+370 run cap . Cycled unit on to check compressor and fan working. Wash and clean condenser coil. Outdoor temperature is 58°. At time of dispatch unit is working.


Brian M.

Brian M. Job Checkin

Found outdoor fan motor failed.


Jason J.

Jason J. Job Checkin

No cooling. I found a blown 25 amp fuse. I checked the contactor,capacitor and connections and found no issues. I replaced the fuse and cycled with a 10 amp draw. Unit is operational at this time.


Jose M.

Jose M. Job Checkin

Club AC Tuneup. T-Stat, #201Sg, Fan Power Humidifier Turn Off, 69*-53*=16* D-T, Blower Motor, R-22, Disconnect, 2=25 Amps Fuse, Electrical, 45+5+440 Dual Run Cap, 61* Outside, Hose Down, Cycled Unit Clean And Check.


Marty T.

Marty T. Job Checkin

Found unit slightly low on refrigerant add 1 pound refrigerant check superheat at 17° per conditions cycle air conditioner due to age of system replacement should be considered instead of repairing.


TJ G.

TJ G. Job Checkin

Cycled system from tstat, all within spec Checked filter,did not need changed Flushed condensation drain Reset tstat Inspected outdoor unit and capacitor, all within spec. Water not available on roof. Rooftop unit is 19 years old, advise planning for replacement in upcoming years.


Brian M.

Brian M. Job Checkin

Found breaker in off position. Turned on breaker and cycled system. System operating properly at this time. Thanks Brian


Cory B.

Cory B. Job Checkin

I reached out to customer multiple times and never responded back.


Jose M.

Jose M. Job Checkin

Club 2=A/C Tuneup. 2=T-Stat, #16x25x1 Air Filter & #201Sg, 2=Drain Trap, 2=Blower Motor, 76*-60*=16 & 70*-52*=18* D-T, 2=R-22, 2= Disconnect, 30+3+370 & 35+3+440 Dual Run Cap, Electrical, 64* Outside, Hose Down, Cycled Unit Clean And Check.


Besham B.

Besham B. Job Checkin

Unit 1 Check t/start change filter check blower motor flush condensate drain. Supply air 48 return air 67. Check disconnect two 20 amps Fuse. Check capacitor 30+5+440 Dual Run Cap. Check contactor Cycled unit on to check fan motor and compressor working. Wash and clean outdoor coil. Outdoor temperature is 58°. At time of dispatch unit is working. Unit 2 Check t/state change filter check blower motor flush condensate drain. Supply air 50* return air 66*. Check disconnect two 20 amps fuse. Checked capacitor 30+5+440 Dual Run Cap. Check contactor cycle unit on to check compressor and fan working . Wash and clean condenser coil. Outdoor temperature 59*. At times of dispatch unit is working.


Jason J.

Jason J. Job Checkin

I lit the pilot and cycled with normal operation.


Cory B.

Cory B. Job Checkin

Reached out to Mary Kay multiples times via phone and email and never has never responded.


Marty T.

Marty T. Job Checkin

Clear condensate trap checked blower motor and filter check contactor capacitor compressor and fan cycle AC to check removed rodents Nast from control compartment cleaned condenser coil


Jason J.

Jason J. Job Checkin

Loose thermostat. I added a new wall anchor and secured it to the wall. The thermostat is secure.