Good service

Found out Furnace Board has Pod's that need to be set properly, furnace will not go to second stage on its own

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous, helpful

Well satisfied.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service .

  • Overall Experience
  • Quality
  • Price
  • Convenience

good

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Pat

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service. Awesome Price.

Everything went well with no complaints.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt, courteous service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Jason J.

Jason J. Job Checkin

Furnace is not heating properly. I found the flame sensor was not reading any microamps upon arrival. I removed cleaned and retested at 2.1 µg. I cycled the furnace for 15 minutes with proper operation. I also replaced the filter with the customers supply. Coustomer could not print the coupon.


Jerry R.

Jerry R. Job Checkin

Furnace replacement


Marty T.

Marty T. Job Checkin

Upon arrival found the gas was not on to the house.


Brian M.

Brian M. Job Checkin

Found unit off on hi limit lock out. This is due to a dirty filter. After changing the filter and resetting the furnace system is operating properly at this time. Thanks Brian and Marty.


Brian M.

Brian M. Job Checkin

Found unit locked out due to open limit. Furnace had overheated due to dirty filter. Replaced filter and reset control board. Cycled system and system is operating properly at this time. Thanks Brian and Marty.


Marty T.

Marty T. Job Checkin

Found feed tube cracked, remove and replace, cycle to check, ok.


Marty T.

Marty T. Job Checkin

Found pressure rising too high Adjust water feed valve lower cycle boiler several times to check leaking from pressure relief stopped


Marty T.

Marty T. Job Checkin

Bypass infinity control with regular thermostat to get heat until tomorrow


Jose M.

Jose M. Job Checkin

upon arrival I found the noise they were hearing was from a water droplet falling onto the fan blade. I added a piece of plastic so the water would follow gravity down onto the water panel. The water was following the roof of the unit and dripping on the fan blade. After this adjustment was made the humidifier was cycled cycled for 20 minutes with no more noises.


Jose M.

Jose M. Job Checkin

We replaced 10=16x25x2 and 16=16x20x2 filters.


Brian M.

Brian M. Job Checkin

Upon arrival customer cycled system. Could not get system to repeat the noise that customer was explaining. Unfortunately we arrive later than 9 AM estimate. And customer has to leave for work right now. He will keep an ion it and try to record the noise when it happens.


Marty T.

Marty T. Job Checkin

Found blower motor failed after running for approximately three minutes. We tried a new capacitor which did not work. Customer does not want to repair at this time. We emailed 2 estimates and will wait to hear from him. System is not running at this time. Thanks Brian and marty


Jason J.

Jason J. Job Checkin

Furnace tuneup. Burner and blower compartments were inspected all safeties and connections were checked. Ignition sequence was cycled . Blower compartment and wheel were checked out. The system was cycled with proper operation. We replaced the filter with the customer supply. The furnace is in proper working order at this time.


Brian M.

Brian M. Job Checkin

Found bad ignitor. Replaced part. Cycled system and system is operating properly at this time. Thanks Brian.


Jose M.

Jose M. Job Checkin

Replace Part. Replace 90% Inducer Assembly, Cycled Unit Fine At This Time.