Marty is the consummate service person for Bay Furnace. I always request him if available for my air conditioner / furnace annual inspections.
Everything from the first contact with the after hours emergency technician to the follow up diagnostic call to the conversation with the sales team was very professional. The installation team was efficient, friendly, knowledgable and thorough. I highly recommend Bay Furnace for your heating and cooling needs. For more than 20 years we have utilized their services and have absolutely no complaints.
Excellent professional demeanor and showed knowledge & expertise in area of the cooling mechanism of the A.C. unit. Jose was concerned and offered me several options to consider for dealing with the problems of the A.C. unit. He was very professional.
Very knowledgeable people working in customer service and on the road.
Service was excellent, as always. Your technician was very professional
Club Furnace And Humidifier. Replace #12Wp. T-Stat, 60 Ohms HSI, Flame Sensor, 90% Inducer Assembly, 3.5†W.C. Gas Valve, Drain Trap, #20x25x5 Air Filter, Electrical, 76* Outside 10+370 Run Cap Blower Motor, “Humidifier “ Hum-Stat, Bypass Open, Water Valve, Solenoid, Feed Tube, Electrical, Drainline, Cycled Unit, Clean And Check.
Club Furnace And Humidifier Tuneup. Replace #35Wp. T-Stat, Spark Igniter, Flame Sensor, 4+370 Run Cap 90% Inducer Assembly, 3.5†W.C Gas Valve, Burner, Drain Trap, 15+370 Run Cap Blower Motor, 71* Outside, “Humidifier†Hum-Stat, Fan Power, Scale Control Insert, Water Valve, Solenoid, Feed Tube, Drainline, Cycled Units, Clean And Check.
Unit 1 Check thermostat check blower check humidifier change filter check hot service ignition 85 ohms. Cycle unit on to check all other components on unit. All others information please check heating Tuneup form. At time of dispatch unit is working. Outdoor temperature is 66* Unit 2 Check thermostat check blower change filter check hot service ignition 49 ohms. Cycle unit on to check all other components on unit. All other information please check heating Tuneup second unit form. At time of dispatch unit is working. Outdoor temperature is 66*.
Clean burners flame sensor condensate trap vestibule and controls change humidifier water panel and filter check all operating and safety controls fire furnace to check low and high fire
Unit Making Noise. Found 220 Line Reading 346 From Breaker Box, Owner Will Electric Company.
Water leaking. I cleaned the condensate trap with CO2.;I cycled with proper operation.
Club Furnace And Humidifier Tuneup. Replace #201Sg. Bypass Humidifier Not Used. T-Stat, 56 Ohms HSI, Flame Sensor, 2-Stage 90% Inducer Assembly, 1.5†& 3.5†W.C. Gas Valve, Drain Trap, Electrical, 132* & 122*-72*=60* & 50* T-R, V.S Blower Motor, 73* Outside, Cycled Unit, Clean And Check.
His budget was a lower than what we could offer.
Replace thermostat and module. Parts were replaced and the unit was cycled with proper operation.
2= Commercial Rooftop A/C Tuneup. Replace 2=#20x25x2 & 4=#16x16x2 Air Filter. 2=T-Stat, 74*-56*=18* & 74* & 62*=12* D-T, 2=Drain Trap, 2= Blower Motor, R-22 & R410A, 80* Outside, Cycled Units, Clean And Check.
No cooling. Repaired low voltage wire at condenser. Rodent chewed the wire. Cycled cooling from tstat with proper operation at this time. Reset tstat.
Follow up diagnosis repair. Replace contactor and insulting 1 ft of armor flex on suction line. At time of dispatch unit is working.
Customer said she feels the system is blowing warm air. Cycle unit on and found the outdoor unit isn’t working. Check capacitor and found it was not reading. Replace capacitor with turbo 200x and cycle unit on to check compressor and fan motor working. At times of dispatch system is working.