8955 E Nichols Ave #200
Centennial, CO 80112
(303) 757-5661

Local Reviews
for broomfield, co

Rated 5.0 out of 5 stars based on 5 customer reviews

Fantastic Service

He found the problem, fixed it, and then performed routine maintenance that was covered by our service plan. Efficient, courteous and kind!

  • Overall Experience
  • Quality
  • Convenience

Good man!

  • Overall Experience
  • Quality
  • Convenience

Super customer service

Got the job done!!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Wonderful a 10 out of 10

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for broomfield, co

Aaron W.

Aaron W. Job Checkin

Broomfield, CO 80020


Tomas M.

Tomas M. Job Checkin

Toilet Repair. Tech: Tomas.


Jay H.

Jay H. Job Checkin

Arrived on site, client said they had no hot water, tried lighting pilot and would not light. Unit is from 2010. Gave diagnostic options to client. After diagnostic, was able to light pilot and water fired up with no issues, waited approximately 20 minutes and everything still working properly. Not very much combustible air in mechanical room, recommended leaving door open, or creating slats in door to allow more airflow. Left estimates with client for replacement. If issues continue, recommend replacing unit based on age as well.


Jay H.

Jay H. Job Checkin

Arrived on site, clients main water shut off below meter was leaking from packing. Client has bucket underneath, says it’s been dripping for almost a year. Went over options and client authorized me to replace main shut off valve. Had city come out and shut water off at curb stop in front yard. Cut out and removed old shut off valve, installed new 3/4” ball valve w/drain. Had city come turn water back on, tested and everything working properly. 1 year warranty parts and labor.


Tomas M.

Tomas M. Job Checkin

Installed 2 Toto, Comfort Height, toilets. Paid in full with a card. Tech: Tomas. Please Mail W/O!


Chris  M.

Chris M. Job Checkin

Chris McQuistion came out due to possible humidifier not working. Performed diagnostic. Found customer is a platinum membership and has not gotten annual performance done on both furnace and humidifier. Performed both services. Changed out humidifier pad. Cleaned entire unit. Checked for proper operations. Humidifier working as should. Next performed performance check on furnace. Changed out filter for customer 20x25x1. Wrote date changed on filter. Checked entire system for sequence of operations. System is heating and operational at this time according to manufacture specifications. No issues at hand. This is all complimentary service due to the maintenance plan. No charge today.


Austin P.

Austin P. Job Checkin

Electrical inspection and 3 GFI’s


Jay H.

Jay H. Job Checkin

Arrived on site, we had recently winterized swamp cooler for client. When we did, we accidentally left the water valve on the hose splitter to swamp cooler on. So when client went to use regular hose, water would spray out of swamp cooler connection. Client is unable to turn valve off based on position against wall. I loosened splitter adapter to be able to shut valve off for swamp cooler. Tightened adapter back on so client can use regular hose in mean time. Everything working properly. Client will have to loosen adapter to turn valve for swamp cooler on and off each year.


Jay H.

Jay H. Job Checkin

Arrived on site, clients sprinkler shut off valve was not fully closing allowing water to continue to vacuum breaker. Gave options to client to replace valve and/or rebuild main water tree. Pressure in home is at 65-70psi. Client authorized me to replace sprinkler shut off valve. Shut water off to home, cut old valve out and installed new 3/4” ball valve w/drain. Positioned drain accordingly and discussed placement with homeowner. Turned water back on, tested and everything working properly. 2 year warranty parts and labor. Client signed up for BVR.


Jordan M.

Jordan M. Job Checkin

Electrical service for chandelier


Jay H.

Jay H. Job Checkin

Arrived on site, clients upstairs bathroom shower would sometimes not allow handle to get to hot water. She had handyman come take a look and was unable to fix. Gave options for repair, client authorized. Tried taking handle apart, and found temperature limit dial to be stripped, not staying in grooves, sometimes would work, other times would come apart and get stuck in cold position. Shut water off to home and drained system, replaced cartridge and set temperature limit hotter. Turned water back on and tested. Everything working properly. Replaced handle and trim. 2 year warranty parts and labor.


Jim W.

Jim W. Job Checkin

Stops and supply lines to check out OK with no leaks. Drainage connections check out OK with no leaks. No leaking below disposer with a possible bad internal seal. No leaks noted underneath the dishwasher With discharging into standpipe, and no back up out to stand pipe. Fill both sink compartments and discharge to check for possible back up through stand pipe in cabinet. No back up noted and drainage is good. Noted moist sheet rock around Studer vent recessed area and noted moist cabinet backing just underneath the countertop at the backside. Noted standing water around base of pull out style kitchen faucet with faucet not in use. Hose connection to head is tight and not leaking. Faucet is defective internally and needs to be replaced To eliminate constant water leaking at the base without being in use and possibly leaking back behind the open grout areas behind the faucet and down to the Studer vent area as noted above. Put excess water on the deck countertop at these open grout


Mark  P.

Mark P. Job Checkin

Checked swamp cooler, found water pump locked up with debris. Cleared, still did not run, cleaned out pan, installed new pump. A/C repair in Brookfield Co


Travis P.

Travis P. Job Checkin

Shower valve was stuck closed and would not open up. Brass stem was broken inside valve body. Ended up replacing entire shower valve and shower head.


Jordan M.

Jordan M. Job Checkin

Jordan on 6-29-21 removed old outlet and installed 30 amp fused disconnect for water heater