Today I arrived on site and performed a summer tune-up on your system. Here's a summary of the work completed: **Air Handler (Attic/Garage):** * Verified overall condition as fair. * Confirmed pleated 1" filtration; customer to handle filter replacements. * Observed indoor coil condition as fair. * Inspected blower wheel, electrical wires, primary drain pan, and secondary drain pan; all in good working order. * Measured return air temperature at 75.0°F and supply air temperature at 55.0°F. **Condenser (Side of House - Heat Pump):** * Verified outdoor coil condition as good and clean. * Tested and confirmed proper operation of blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring. **Condensate Drain System:** * Cleared the drain line. * Cleaned out the primary pan. **Final Steps:** * Restored power to the units. * Confirmed system is now working properly. Tallahassee Fl View my findings