Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Closet):** * Checked pleated 1" filter (20x20x1), condition fair. * Indoor coil condition fair and clean. **Outdoor Unit (Heat Pump on Side of House):** * Outdoor coil condition fair and clean. * Tested and inspected electrical components: blower motor, heat strip kit, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring; all working properly within manufacturer's specs. * Inspected blower wheel, primary drain pan, and secured electrical wires; all in good condition and working properly. **System Performance:** * Return air temperature: 82.0°F/85°F. * Supply air temperature: 113.3°F/110.6°F. * Cleared condensate drain line, cleaned out primary pan, and tested safety switch. **Additional Actions:** * Dusted the thermostat and restored power to the units. * Tested thermostat operation.