Brandon Graham is personable and a good rep for Benson. We were unaware our surge protection was from the house in and not on the outside. He installed the appropriate surge protection for the units on the outside. As well, he called both days to let us know he was on the way. We are extremely satisfied with the service.
Simply the best service ever! Very nice technicians and very knowledgeable too! Completely happy with Benson Heating and Air Conditioning
Job Summary Today, I arrived on site to perform maintenance on the HVAC system located in the garage attic. Overall Equipment Condition Equipment condition assessed as fair. Indoor Unit Details Type: Air Handler Filtration: Replaced spare filters (Pleated 1") Filter Sizes: 20x30x1 & 12x12x1 Indoor Coil Condition: Fair Outdoor Unit Details Location: Side of House Type: Heat Pump Outdoor Coil Condition: Fair, Clean Electrical Components Tested All components tested and functioning within manufacturer specifications: Blower Motor Heat Strip Kit Condenser Fan Motor Compressor Blower Run Capacitor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring Inspections Conducted Components in good condition: Blower Wheel Secondary Drain Pan Primary Drain Pan Electrical Wires Secured No components found in poor condition. Temperature Readings Return Air Temperature: 74.0°F Supply Air Temperature: 120.0°F Condensate Drain System Cleared drain line a
I performed a winter time maintenance on your HVAC equipment today. Here is a summary of the work I completed: Overall Equipment Condition: Good Location, Type, and Picture of Indoor Unit: Garage, Attic, Air Handler Area Unit Services: Whole house Filtration: Pleated 1", Replaced Today Filter Size: 20x30x1, 12x12x1 Condition of Indoor Coil: Good Location, Type, and Picture of Outdoor Unit: Back Yard, Heat Pump Condition of Outdoor Coil: Good, Cleaned Today I tested and inspected the following electrical components on your equipment and found them to be working properly within the manufacturers recommended specs and amperage's: Blower Motor Heat Strip Kit Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Contactor Defrost Control Board Electrical Wiring Electric Heat Strip Kit Safety's There were no electrical components that were not working properly or not within the manufacturers recommended specs and amperage's. I inspected the following components on your