N967 Quality Drive
Greenville, WI 54942
920-750-7138

Local Reviews
for neenah, wi

Rated 4.9 out of 5 stars based on 211 customer reviews

Excellent and very helpful!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very efficient and seemed to live his work

Very positive everyone sent was polite and accurate and knew the job to be done

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Very nice man

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

High Quality and Service

We've used Black-Hawk for our home and investment property - they never disappoint and do a terrific job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast and friendly!

Dan came a little early which was great. He did an excellent job explaining how the service went and was very helpful and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Dry friendly and helpful service technician

He was so thorough and explained everything he did for the best service of our furnace.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good Experience

Dan was very friendly, explained everything clearly, offered additional services and generally made me feel good about using Black Haak.

  • Overall Experience
  • Quality
  • Price
  • Convenience

The tech did a great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for neenah, wi

Gary  P.

Gary P. Job Checkin

Start up completed Adjusted gas valve


Kody W.

Kody W. Job Checkin

I removed the old fill valve and backflow preventer. I installed the new fill valve and backflow preventer. Cycled the boiler. It’s working properly.


Gary  P.

Gary P. Job Checkin

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and blower motor Checked your condensate drain trap Replaced water panel on humidifier Furnace working well at this time Tune ups maintain warranty


Hunter D.

Hunter D. Job Checkin

We had the wrong gas valve. We will return with the correct one and finish the job. Gary- installed correct valve, system working well, dialed in gas valve 1.75 wci, 3.50 wci Tune ups are for two homes Please invoice


Craig W.

Craig W. Job Checkin

We will provide and install the Aprilaire 600A humidifier. Completed installation of an Aprilaire 600 humidifier. Mounted the humidifier on the return drop and ducted the bypass to the supply plenum. Ran control wiring from duct mounted humidistat to the furnace and connected them. Run tested the humidifier for proper operation. Thank you for choosing Black-Haak Heating and Electric. Please take a moment to fill out our online survey.


Gary  P.

Gary P. Job Checkin

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter and replaced Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnace working well at this time Tune ups maintain warranty


Hunter D.

Hunter D. Job Checkin

Came out to investigate a no heat. The igniter would glow but the burners wouldn’t light. I didn’t hear any gas coming out of the manifold. I cleared the drain lines and pressure hoses to eliminate a pressure issue, no success. I checked power to the gas valve and had 24v from the board. Gas valve bearings are bad. Valve will need to be replaced. Part is under warranty. We will return to replace.


Gary  P.

Gary P. Job Checkin

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter And replaced Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnace working well at this time Checked humidifier and replaced water panel Water on floor around dehumidifier, caused by drain line having no down slope. I adjusted unit for downslope. Water should be gone in a day or two Tune ups maintain warranty


Hunter D.

Hunter D. Job Checkin

Performed the new furnace start up. No gas leaks detected. Combustion readings were normal. No CO detected in the air. Drain is working. High limit passed the safety check. Heat rise was 48°. Unit is heating properly.


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Checked heat exchanger, found two chambers with cracks forming. Checked, removed and cleaned burners and flame sensor. Found igniter/flame rod assembly is worn and needing to be replaced. Ventor motor bearings are worn and in need to replacement. Checked and tighten electrical connections and clamps. Cleared drain lines. Preformed combustion test and found elevated levels of XS air in the exhaust. This is an indication of clogged secondary heat exchanger. Also found that system was going off on high limit safety. This is confirmation of blockage. Average life expectancy for this unit is 14 years, this system is well over that time and in very poor condition. Second opinion set for today for options. No charges pending results of second opinion. Job complete.


Anthony N.

Anthony N. Job Checkin

Performed a preferred customer level 1 cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time.


Hunter D.

Hunter D. Job Checkin

Replaced the rubber 90° elbow on the ventor motor. Cycled the furnace. Unit is heating properly. I also glued the PVC terminations outside. Customer requested we didn’t glue them during install so they could install the siding easier.


Anthony N.

Anthony N. Job Checkin

Was here for a furnace cleaning. Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time. Found that the furnace filter is dirty. The customer will change the filter. The customer also wanted me to check the humidifier. Found that a one of the wires was broken from one terminal. Rewired the humidifier. It is now working at this time. Also the customer wanted me to check his HRV. Couldn’t service it due to the drywall around it.


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Checked heat exchanger. Ok. Checked, removed, and cleaned burners and flame sensor. Checked and tightened electrical connections and clamps. Checked and adjusted gas pressures to maximize efficiency. Cleared drain lines. Checked and replaced filter. Preformed combustion test. Found normal levels in exhaust. No CO found in airstream. System operating normal at this time. Job complete.


Dan E.

Dan E. Job Checkin

Fireplace issue. Customer stated that fireplace would go out after several hours of use. The pilot light was lit. They would then shut it off. A few times it would come back on after ten mins of shutting down. Found that customer was not using fireplace fan while operating. This caused the system to go out on heat limit. No issues found with the fireplace. Customer would like fireplace cleaned when ac is cleaned. Job complete.