Gary was friendly and knowledgeable. He explained everything and was great.
I recently purchased a new home with features I was not familiar with. The technician went through them with me (i.e. Aprilaire system), so I can maintain them between calls.
We have had Black-Haak Heating since 1984 because of their service and the employees they have working for them.
Technician was kind and courteous. Extremely knowledgeable. Respectful of our property. Would definitely recommend.
Friendly, knowledgeable technicians. Love our furance and how evenly warm our home is. Best decision we made when we needed to replace our old furnace.
Dan was great! On-time, great communication thru the process, and very knowledgeable. Highly recommend and very professional. Thank you!
The Technician and reps kept in contact with me at every step along the process and were fast and efficient. The technician was very friendly and knowledgeable, even upgraded me to a bundled package fir heating and cooling inspection. Gives me peace of mind going into the winter season. Recommend.
Pleasant. personable technicians, fully explaining everything needed.
Furnace start up. Cycled system. Checked electrical connections and clamps. Found ventor motor clamp installed incorrectly. Removed and installed correctly. Tightened connections. Checked incoming gas pressure. Checked and adjusted outgoing gas pressures to maximize efficiency. Checked and adjusted drain line. Preformed combustion test and normal levels found. Customer pointed out damage to vibration boot on supply trunk. This may have been caused from duct work moving due to install. Office to follow up for repair appointment. System operating normal at this time. Job complete.
No heat. Cycled system. Igniter would energize, flame would light, then system would drop out. Cycled several times with similar results. Removed burner box and gas manifold. Checked igniter, tested normal. Checked low voltage. Correct voltage. High voltage was tested. Correct voltage. Cleaned and checked flame sensor. Flame sensor was very corroded and dirty. Re installed burner box and flame sensor. Cycled system. System fired normal and continued to operate normal for over 15 mins. System is in major need of maintenance to help ensure proper operation. System operating normal at this time. Job complete.
Furnace clean and tune. Cycled system. Checked heat exchanger, ok. Checked, removed, and cleaned burners and flame sensor, both ok. Checked electrical connections and clamps, tightened . Cleared drain lines. Checked and adjusted gas pressures to maximize efficiency. Preformed combustion test and found normal levels in exhaust. No CO found in airstream. System operating normal at this time. Job complete.
Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time.
Furnace start up. Cycled system. Checked clamps. Checked adjusted gas pressures to maximize efficiency. Tightened electrical connections. Checked for sequence of operation. Preformed combustion test. No CO found in airstream. System operating normal at this time. Job complete.
Removed, cleaned and installed gas burners Removed, cleaned and installed flame sensor Inspected heat exchanger Tested igniter Checked blower motor Checked and tested ventor motor Checked filter Adjusted gas outlet pressure to OEM spec Preformed leak check on indoor coil System working well at this time Tune ups maintain warranty Now scheduling spring AC tune ups
Performed electrical work quoted by Kevin. Replaced (3) light fixtures and two switches. Added canopy cover to another light. Installed switch in the correct orientation.
Furnace clean and tune. 1st year. Cycled system. Checked heat exchanger, ok. Checked, removed, and cleaned burners and flame sensor. Both ok. Checked igniter, ok. Checked and tightened electrical connections and clamps. Cleared drain lines. Found venting clamp incorrectly installed. Removed and installed correctly. Checked and adjusted gas pressures to maximize efficiency. Preformed combustion test and found normal levels in exhaust. No CO found in airstream. Replaced fi,yer. System operating normal at this time. Job complete.
Furnace clean and tune. Cycled system. Checked heat exchanger. Found some rust and corrosion in all chambers. No visible cracks found with camera. Cleared drain line. Found some obstructions. Checked and tightened electrical connections and clamps. Checked and cleaned flame sensor. Found heavy corrosion on flame sensor. Cleaned as best as I can. Igniter tested normal. Found evidence of bearings getting worn in Ventor motor. Preformed combustion test, normal levels found in exhaust. No CO found in airstream. When cycling system to heat, thermostat would not allow me to increase set temp. Customer stated that they have issues two times that furnace would shut down prematurely. This, along with the situation I found when dealing with thermostat, indicates that the thermostat is failing. I recommend replacement of thermostat. Average life expectancy for this unit is 14 years. This system is past that time period and future failure is expected. Recommend second opinion for options to avoid
No heat. Home under renovations No signal from tstat Gas turned off outside home. Angelica instructed me to turn it on as it was safe Wired tstat for heat only Turned on gas System working. Second opinion /estimate for replacement
Performed furnace clean and tune. Found the ignitor is weak and the exhaust motor bearings are wearing out. The furnace is 12 years old. Average life expectancy is 12-15 years. The furnace is heating at this time.
Performed two preferred customer fireplace cleanings. Wiped down and vacuumed both of the fireplaces. Cleaned the pilot assembly. Cleaned the fireplace glass. Tested both the fireplaces. No issues with the units at this time.
Furnace clean and tune. Cycled system. Checked heat exchanger, found all chambers to be rusted and corroded. No visible cracks found with camera. Deep etching and rust found. Checked, removed, and cleaned burners and flame sensor, both ok. Checked and tightened electrical connections and clamps. Cleared drain lines. Found rusting and evidence of water leak from transition assembly. Preformed combustion test and found normal levels is exhaust. No CO found in airstream. Average life expectancy for this unit is 14 years. This unit is showing signs of getting worn. Due to age, condition, and cost of repair, second opinion is recommended. System operating normal at this time, but future failure is expected. Removed old heat register and installed new. Fireplace clean and tune. Cycled fireplace. Ok. Cleaned glass. Cleaned walls, logs, ignition system, and under unit. Cleaned ignition system as best as I could. It is very hard to reach due to its placement to the manifold. System operating
Removed, cleaned and installed gas burners Removed, cleaned and installed flame sensor Inspected heat exchanger Tested igniter Checked condensate trap Checked blower motor Checked and tested ventor motor Checked filter Adjusted gas outlet pressure to OEM spec System working well at this time Now scheduling spring AC tune ups