N967 Quality Drive
Greenville, WI 54942
920-750-7138

Local Reviews
for oshkosh, wi

Rated 4.8 out of 5 stars based on 70 customer reviews

Great service!

Technician was kind and courteous. Extremely knowledgeable. Respectful of our property. Would definitely recommend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quality Service

Friendly, knowledgeable technicians. Love our furance and how evenly warm our home is. Best decision we made when we needed to replace our old furnace.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service, fair price!

Dan was great! On-time, great communication thru the process, and very knowledgeable. Highly recommend and very professional. Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast, friendly service.

The Technician and reps kept in contact with me at every step along the process and were fast and efficient. The technician was very friendly and knowledgeable, even upgraded me to a bundled package fir heating and cooling inspection. Gives me peace of mind going into the winter season. Recommend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Both guys were great thank you

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

Pleasant. personable technicians, fully explaining everything needed.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Gre

Great srrvice.. heplful advice

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Solid HVAC contractor. . .no gimmicks or BS

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Dan was able to answer all of my questions - very professional and personable, would highly recommend

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for oshkosh, wi

Anthony N.

Anthony N. Job Checkin

Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time.


Hunter D.

Hunter D. Job Checkin

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 53°. Unit is heating properly. We will return in spring for the AC.


Hunter D.

Hunter D. Job Checkin

Performed the level 2 furnace cleaning. Burners and flame sensor are clean. Heat exchanger looks good. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 41°. Unit is heating properly. We will return in the sprin for the AC.


Hunter D.

Hunter D. Job Checkin

Performed the level 2 furnace and fireplace cleanings. Furnace: Burners and flame sensor are clean. Heat exchanger is a little rusty. Combustion readings were normal. No CO detected in the air. Drain is clear. Heat rise was 49°. Only issue I found was the inducer motor is starting to sound worn, but still working at this time. Unit is heating properly. Fireplace: Cleaned to pilot. Readjusted the logs. Cleaned off the glass. Added in new embers. Wiped away dust from the screen. Cycled the fireplace. Unit is heat properly.


Gary  P.

Gary P. Job Checkin

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter And replaced Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnace working well at this time Tune ups maintain warranty


Gary  P.

Gary P. Job Checkin

Removed and cleaned and reinstalled flame sensor Removed and cleaned and reinstalled gas burners Checked gas outlet pressure Checked igniter Checked filter Inspected and tested inducer motor and blower motor Checked your condensate drain trap Furnace working well at this time Tune ups maintain warranty


Anthony N.

Anthony N. Job Checkin

Performed a preferred customer furnace cleaning. Cleaned the burners and the flame sensor. Checked the furnace heat exchanger. Wiped down the inside of the furnace. Checked the electrical. Cycled the furnace and performed a furnace combustion test. No issues with the furnace at this time.


Evan A.

Evan A. Job Checkin

Bill mentioned a couple of furnace related issues to me when arrived. One zone dampers is buzzing and not closing while it’s thermostat is off. While the furnace was running I noticed the unit louder than it should be and decided to clean the furnace also. The transition assembly is cracked and should be replaced (picture added). I removed and cleaned the burners and flame sensor. Cleared the drains and pressure tubing. Secured wired connections. Checked gas pressures. Checked exhaust readings, all normal. The humidifier canister looks good still. The zone damper right above the venting has failed, I will have the office quote to replace it. The filter is getting pretty dirty, I recommend replacing it. I cleaned the boiler. Removed and cleaned the sparker. Expansion tank is good. Removed and cleaned out the drain trap. Fill valve is working properly, system pressure is at 16psi. Exhaust readings look good. I installed the prestige thermostat kit, including the thermostat, interface m


Mark P.

Mark P. Job Checkin

Installed gas furnace


Hunter D.

Hunter D. Job Checkin

Came out to investigate a no heat. Customer said he thought the furnace went out on a limit issue again. Furnace was running and holding at 64° when I arrived. I cycled the furnace four times without any issues. I checked the filter and it was okay. Heat rise was 45°. I told him to monitor everything and call us back if necessary.


Hunter D.

Hunter D. Job Checkin

Performed the level 2 furnace and modine cleanings. Furnace: Burners and flame sensor are clean. Heat exchanger looks good. Combustion readings were normal. No CO detected in the air. Drain is clear. High limit passed the safety check. Heat rise was 38°. Unit is heating properly. Modine: I wiped away dust on both the interior and exterior of the unit. Cleaned the burners and flame sensor. No CO detected in the air. Exhaust readings were normal. Unit is heating properly. We will call to schedule the AC cleaning in the spring.


Dan E.

Dan E. Job Checkin

Delivered media pads. Customer has premier one filters. Job complete.


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Checked heat exchanger. Some surface rust and corrosion found, no visible cracks found. Checked, removed, and cleaned burners and flame sensor. Igniter tested normal. Burners were very corroded. Checked and tightened electrical connections and clamps. Found some loose drain lines. Tightened as best as I could. Cleared drain line. Checked and adjusted gas pressures to maximize efficiency. Preformed combustion test. Normal levels found. No CO found in airstream. System operating normal at this time. Job complete.


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Checked heat exchanger, ok. Checked, removed, and cleaned burners and flame sensor. Igniter tested normal. Checked and adjusted gas pressures to maximize efficiency. Checked and tightened electrical connections and clamps. Cleared drain line. Preformed combustion test. Found all levels in exhaust were normal. I CO found in airstream. System operating normal at this time. Job complete.


Dan E.

Dan E. Job Checkin

Furnace clean and tune. Cycled system. Checked heat exchanger, ok. No rust or corrosion found in chambers. Checked, removed, and cleaned burners and flame sensor. Both are in normal condition. Checked and adjusted gas pressures to maximize efficiency. Checked electrical connections and clamps. Tightened all. Ventor motor bearings are in normal condition. No leaks found. Checked filter. Filter is ok. Recommend replacement of filter before the beginning of the year. Preformed combustion test. Normal levels found. No CO found in airstream. System is operating normal at this time. Job complete.