Joe P.

Joe P. Job Checkin

I responded to an HVAC repair call for no cooling. After inspecting the system, I found a faulty capacitor. I replaced the capacitor and tested the condenser fan to ensure proper operation. The system is now cooling efficiently and running smoothly.


Joe P.

Joe P. Job Checkin

Installed a Mitsubishi MZ-GL12NA mini-split system today. Mounted indoor unit on living room wall using included bracket. Ran line set through 2.5" wall sleeve, connecting to outdoor unit placed on concrete pad. Vacuumed system with Yellow Jacket 93600 vacuum pump. Charged with R410A refrigerant using Fieldpiece SMAN360 manifold. Wired units to Emerson ST55 thermostat. Sealed penetrations with polyurethane foam. Tested system operation, achieving 18°F delta T. Completed installation in 6 hours.


David C.

David C. Job Checkin

Performed AC repair on a Carrier 38HDDR060 heat pump system today. Diagnosed faulty dual capacitor using Fluke 902 FC HVAC meter. Replaced with new 45/5 MFD TradePro dual run capacitor. Cleaned condenser coils using Nu-Calgon 4291-08 Evap Foam No Rinse. Recharged system with R410A refrigerant using Fieldpiece SMAN360 digital manifold. Checked superheat and subcooling values. Replaced worn contactor with Packard C230B 2-pole 30 amp contactor. Lubricated fan motor bearings with 3-IN-ONE motor oil. Tested system operation, achieving 20°F delta T across evaporator coil. Completed repair in 3.5 hours, restoring optimal cooling performance.


Charles L.

Charles L. Job Checkin

Diagnosed air conditioner not cooling. Found low refrigerant levels and a faulty capacitor. Recharged the system with refrigerant to restore cooling capacity. Replaced the faulty capacitor to ensure proper compressor function. Cleaned condenser coils and checked thermostat calibration. Conducted a system performance test to verify optimal operation. Air conditioner is now cooling effectively. Client reviewed and approved the repair.


Joe P.

Joe P. Job Checkin

I provided an estimate for replacing an old AC unit with a new Daikin Inverter system. The quote included removal costs, installation of the new unit, ductwork adjustments, and a programmable thermostat. All equipment specifications and warranty details were thoroughly explained.


David C.

David C. Job Checkin

Completed a heating replacement, installing a new energy-efficient furnace to improve heating capabilities for a residential property. Verified proper installation and conducted system tests.


Charles L.

Charles L. Job Checkin

Heating repair: A customer expressed concern about uneven heating in their home. I discovered a zoning issue in the HVAC system. After recalibrating the dampers and adjusting the thermostat settings, I achieved balanced heating throughout the house.


Charles L.

Charles L. Job Checkin