521 J PL 625
Plano , TX 75074
469-252-0599

Local Reviews
for richardson, tx

Rated 5.0 out of 5 stars based on 6 customer reviews

Great service!!

Answered all my questions

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

He is very very good. He is iinformed confident and very polite and personable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast and efficient service

Mike Rea explained everything and gave me options to help me make a final decision. I very much appreciate that he was professional, efficient and patient in explaining each option.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always great service.

George, Michael and Nick are great to work with. Always provide great service, explain what they are doing and provide multiple options to fix.

  • Overall Experience
  • Quality
  • Price
  • Convenience

You guys rock! THANK YOU!

Couldn't be happier. George is awesome! Thank you to Michael for the great prices.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for richardson, tx

Kelly Y.

Kelly Y. Job Checkin

Springtime Air Conditioning Maintenance for a residential customer near Canyon Creek. Came out on 1 system maintenance Checked pressures checked temp split checked drain lines checked condenser coil checked bearings checked blades checked electrical connections checked contactors checked run capacitors checked Amp draws checked filter Found Clogged drain Bad 40/5 run capacitor / replaced during visit Dirty filter Dirty condenser coil Bad light in uv air purifier No surge protection


Jeremy P.

Jeremy P. Job Checkin

Spring Air Conditioning Maintenance for a residential homeowner in Richardson. Performed a three system maintenance checking cooling. Checked inside units blower amps, electrical and mechanical components, safety components, changed customer-supplied filters, blew out the drain line. Then checked outdoor units Freon levels and amp draws, everything checked out properly. Washed outdoor coils. Customer happy on departure.


Kelly Y.

Kelly Y. Job Checkin

Air Conditioning Maintenance for a residential homeowner in Richardson. Came out on 3 system maintenance checked temp split, checked pressures, checked contactors, checked run capacitors, checked drain lines, checked filters, checked ductwork, checked Amp draws, checked bearings, checked blades, and checked electrical connections.


Kelly Y.

Kelly Y. Job Checkin

Spring HVAC Maintenance for a residential customer. Came out on zoned one system maintenance Checked pressures checked run caps checked temp split checked coils checked ductwork checked insulation levels checked bearings checked contactors checked blades checked drain line changed homeowner supplied 20x20x4 filter checked breakers Found Capacitor 70 is reading 67.2 just above bad specs possibly replace No surge protection No indoor air quality


Kelly Y.

Kelly Y. Job Checkin

Air Conditioning Maintenance Service for a residential homeowner. Came out on 1 system maintenance Checked contactors checked capacitors checked pressures checked temp split checked drain line checked filter checked Amp draws checked electrical connections checked bearings checked blades. Found No surge protection No Indoor Air Quality. The capacitor for the compressor is starting to get low/near bad specs will keep an eye on it. (45/5)


Kelly Y.

Kelly Y. Job Checkin

Came out on 1 system maintenance. Checked bearings checked blades checked drain lines checked insulation levels checked Amp draws checked temp split checked pressures checked electrical connections checked contactors checked capacitors changed filter during visit checked coils Found 80mfd run cap reading 70 means it is considered bad and should replace No surge protection No IAQ


Kelly Y.

Kelly Y. Job Checkin

Came out on plumbing inspection. Checked water heater shut offs checked sink shut offs in both bathrooms and kitchen checked showers in both bathrooms checked toilets in both bathrooms. Found Master bath cold water shut off nob is broken under sink Customer states also that the toilet in main bathroom on occasion needs to be flushed 2 times to get toiletries down toilet Customer also states sometimes secondary bathroom toilet doesn't fill up immediately all the time Secondary bathroom shut offs stuck. unable to shut off water to sink hot or cold


Kelly Y.

Kelly Y. Job Checkin

The main screen on both water heaters were alerting for the condensate lines to be clean. The condensate line were clogged with dirt,rocks, and rust. Both lines were removed and cleaned thoroughly and put back onto the units. There is no longer an alarm for the condensate lines.


Kelly Y.

Kelly Y. Job Checkin

Upon arrival found that system has an I comfort thermostat that is having issues, tried resetting thermostat and screen still blank. System has a communicating xc21 for outdoor unit which makes system true communicating. Thermostat will have to be replaced with a Lennox s-30 thermostat. Thermostat is out of warranty, homeowner approved replacement of thermostat, part ordered at Lennox in Allen order#33731293 Also performed a one system maintenance checking heating, checked all electrical, mechanical, and safety components. Checked amp draws, cleaned flame sensor, and changed out customer supplied filter. Equipment wise everything is operating properly at this time.


Kelly Y.

Kelly Y. Job Checkin

Upon arrival found Dow system not heating. Thermostat error code said no flame detected, checked inside unit and found everything connected. Turned system on and found that the gas valve was stuck. Tried to unstick the valve and was not successful. Valve is under warranty but labor is not. Homeowner agreed to pay labor to replace valve. Homeowner refused to pay service fee.


Kelly Y.

Kelly Y. Job Checkin

Upstairs and masters bedroom furnaces


Kelly Y.

Kelly Y. Job Checkin

Checked amp draws on inducer fan motor and blower motor, cleaned flame sensor checked air filter, checked safety devices, checked heat exchanger it was good, check igniter


Kelly Y.

Kelly Y. Job Checkin

Checked amp draws on inducer fan motor and blower motor, cleaned flame sensor checked air filter, checked safety devices, checked heat exchanger it was good, check igniter


Kelly Y.

Kelly Y. Job Checkin

Performed a three system maintenance checking heating, checked all electrical and mechanical components and safety switches. Checked amp draws. All systems are heating. Found that the gas valves for the master system and upstairs system are getting stuck on first try to ignite burners. Valves are under warranty. John would like to move forward with replacing both gas valves. Parts ordered at Lennox in Allen. Will need to reschedule and come back out to replace valves.


Kelly Y.

Kelly Y. Job Checkin

Open unit up and check system for leaks