1570 Old York Road
Abington, PA 19001
215-659-4343

Our Top Cities


Local Reviews
for chalfont, pa

Rated 5.0 out of 5 stars based on 6 customer reviews

Thanks

  • Overall Experience
  • Quality
  • Price
  • Convenience

Winter service

Good experience, Shane was on time, efficient and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Knowledgeable and honest service


Response from Chud Air Conditioning & Heating:

Charles, thank you for the 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Dryer vent cleaning

Professional and efficient


Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you Richard.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Dryer Vent Cleaning

I was able to schedule an appointment right away. The Chud team arrived on time and were very professional. My dryer vent exits above a second story window and snakes through 2 walls, so it was a bit tricky. I'm very happy with their work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!


Response from Chud Air Conditioning & Heating:

Jeff, thanks for the 5 stars!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for chalfont, pa

shane@chudcompany.com

shane@chudcompany.com Job Checkin

Did a maintenance on a Goodman gas furnace. During the maintenance I clean the flame sensor, also cleaned out the burner box and the blower motor housing. Checked amps on the inducer motor and blower motor which both me to furnace specs. Changed out the 20 x 28x 4 pop-up filter. Also cleared out inducer port. System is operating properly at this point. I will be recommending a new expansion tank for the water heater because it has failed. M# GMEC800804BNAA s#1908095594


shane@chudcompany.com

shane@chudcompany.com Job Checkin

Did a preventative maintenance on a LP furnace. During the maintenance I clean the flame sensor. Cleaned out the burner box and the blower motor housing. Did a amp check on the inducer motor and the blower motor which both meet the furnace specs. Changed out the 20 x 25 x 1 filter did a combustion test the ppm was 31. Also cleaned out the trap and made sure it was draining properly and service the humidifier changed out the number 35 panel wiped the entire thing down and made sure the drain was clear. System is operating properly at this point. M#EL296UH110XV60C-05 s#5915K06383


shane@chudcompany.com

shane@chudcompany.com Job Checkin

Did a preventative maintenance on a gas furnace. Clean the flame sensor, did an amp check on the inducer motor and the blower motor Both are running in furnace specs. Also did a combustion test the ppm what is 31 oxygen level was 8 and The efficiency was 93%. Customer changed out 16 x 25 x 5 filter. Also made sure it was draining properly and that the condensate pump is working. System is operating properly at this point. M# SLP98UH090V60C-02 s#5911E22738


Paul A.

Paul A. Job Checkin

Did they maintenance on a Lennox gas furnace. During the maintenance I clean flame sensor and ohm the HSI. Also did a combustion test the PPM was 21 and the O2 was 19. Cleaned out the burner box and the blower motor housing. And I did an amp check on the inducer motor and blower motor which both meet the furnace specs. And changed out the 16 x 25 x1 Filter. System is operating properly at this point m#EL280UH070E36A-01 s#5919G14317 customer would like receipt mailed to them.


Jonathan C.

Jonathan C. Job Checkin

Performed a 4 bedroom duct cleaning. Hooked up the hepa vacuum and blew out each supply and return vent with compressed air. We also cleaned the supply and return truck lines. After that we sanitized throughout all ductwork. System is working properly at this time.


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 3 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Performed rooftop dryer vent cleaning from the inside using brushes. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Frank B.

Frank B. Job Checkin

Performed a preventive maintenance for air-conditioning system. This maintenance free with new install. Didn’t need to replace the #401 Media Air Filter at this time. Filter was still in fair shape. Customer does supply them. Inspected all the electrical components. Inspected the gravity drain that goes to the French drain 4 feet away. Drain piping is clear flowing without restrictions. Tested the amp draw from the compressor, blower and fan motor. All are operating within manufacturer spec. Tested the temperature split between the supply and return. System is operating at a 20° differential on an 88° day. Wrapped a little bit of insulation around the TXV due to it sweating causing moisture to run down the coil cabinet into furnace. Insulation will prevent it from sweating. Confirmed proper high and low voltages. System is operating properly at this time.


Sebastian R.

Sebastian R. Job Checkin

Performed preventative maintenance on Lennox AC system. Replaced 20x25x1 air filter provided by the customer. Tested evaporator coil pan and condensate drain line for proper drainage. Temperature split is at 22° With a supply air temperature of 46°. This unit has bathe proper refrigerant charge. Compressor-7.2 RLA Condenser fan motor-1.0FLA . Both of these readings are within the amperage rating for this unit. System is operating properly at this time and is ready for the upcoming season.


Paul T.

Paul T. Job Checkin

Removed the old condenser coil. Installed the new condenser coil and brazed in all connections. Pressure tested with nitrogen to ensure that there are no leaks. Pulled a vacuum and got the system to 500 microns. I charged the system with 7lbs of 410-A refrigerant and ran the system. The system has a temperature split of 20°. And the refrigerant pressures are 110/253. The system is operating properly at this time and is ready for the air conditioning season.


Paul T.

Paul T. Job Checkin

Came out today for a Lennox heat pump that has a leak in the condenser coil. Lennox heat pump model #14hpx-030-230-22, serial #1918j10671. Upon arrival the homeowner stated that another company came out to investigate the system not operating (through the home warranty). They charged the system with nitrogen and told the homeowner he had a leak. Upon arrival the system had a slight nitrogen charge and I could hear it leaking. I used micro leak bubbles around the area that was hissing. Sure enough there is a leak in the elbow of the condenser coil. The condenser coil will have to be replaced and the system should be covered under the manufacture warranty.


Anthony  C.

Anthony C. Job Checkin

Performed preventative maintenance on Lennox Gas Furnace. Filter does not need to be replaced until the Spring of 2022. Cleaned and inspected burners, flame sensor and blower compartment. Raised temperature two degrees and verified sequence of operations. System is working properly at this time and is ready for the season!


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a high efficiency Lennox furnace. I observed the system starting normally. I took a combustion analysis test and got the following readings, o2 is at 10%, co is at 3ppm and the system is operating at 93% efficiency. The amp draws for the blower motor and inducer motor are within normal range. I observed the system shut down normally once it reached the desired temperature. I removed and cleaned carbon off of the flame sensor. Cleaned out the burners and burner box. Checked all electrical components needed for heating. The homeowner recently replaced the air filter and water panel on the humidifier. The system is operating properly at this time.


Keith R.

Keith R. Job Checkin

Performed dryer vent cleaning. Dryer vent, duct, and flex hose is clear of lint at this time. Dryer is brand new so lint trap did not need to be cleaned. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years. Thank you for your business! Customer had a 10% off coupon


Frank B.

Frank B. Job Checkin

Performed preventative maintenance for gas furnace. Cleaned out burners and flame sensor. Replaced the one inch air filter. Inspected all electrical components. Performed a combustion analysis. System is operating at 84% efficiency with a CO level of 9ppm. Inspected the gas piping for any leaks. No leaks present at this time. System is operating properly at this time.


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on 2 systems. All vents and ductwork are clear of dust and debris at this time. Both units are functioning properly at this time. Recommend duct cleaning every 2-3 years. Thank you for your business!