1570 Old York Road
Abington, PA 19001
215-659-4343

Local Reviews

Rated 4.9 out of 5 stars based on 1447 customer reviews

Great experience

Shane did a great job, he is friendly, efficient and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Tom was a great tech. Very comfortable having him here and very knowledgeable.


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience, Charles & Lori, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Very informative and skilled.


Response from Chud Air Conditioning & Heating:

Rick, thank you for leaving Chud a 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Keith was personable, knowledgeable & professional. He along with his assistant did an excellent & clean job duct cleaning. Thank you.


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience, Joanne, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Shane, the technician, arrived on time, and was very respectful and competent. Provided outstanding service across the board!


Response from Chud Air Conditioning & Heating:

Hi George, we appreciate the good review. Chud works hard to create a good experience and reviews like this make it all worth it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!


Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you Sheila.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from Chud Air Conditioning & Heating:

5 stars, thank you James!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

5 stars, effective efficient friendly professional overall just great.


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Maureen. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Professional, friendly, helpful, efficient overall just 5 stars


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Maureen. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt, courteous and knowledgeable technician.

Reliable customer service.


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review George. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Professional and friendly


Response from Chud Air Conditioning & Heating:

Your 5-star review means a lot to us!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

He knew his job and was very polite.


Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you, Sylvester & Gwen.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Great service! Very friendly and explained everything he was going to do along with how to maintain it until the next service.


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience, Patrick, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!


Response from Chud Air Conditioning & Heating:

5 stars, thank you Linda!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

Would use again


Response from Chud Air Conditioning & Heating:

Kimberly, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Mandeep B.

Mandeep B. Job Checkin


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 4 bedroom home. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!


Paul T.

Paul T. Job Checkin

Came out today for a no ac call for a Lennox ac system. Model #Hs23-411-1p, serial #5193M13493. Upon arrival the homeowner stated that the outdoor unit will not turn on. I called for ac and observed the system starting normally. The indoor unit fired up right away. The condenser unit however would not turn on. I opened the access panel and noted that the contactor was not engaged. I followed the voltage to the low pressure switch. I reset the switch and called for ac again. The pressure switch would not reset. I checked the standing pressures and the high side pressure was .03 and the low side is at 63. The system utilizes R-22 refrigerant which has been phased out. At this time I recommend updating the system to one that utilizes 410-a refrigerant.


Shane A.

Shane A. Job Checkin

Model # RG250L6N Serial # YE49769843 Customer called about no hot water. The pilot was not lightning because the gas valve is stuck shut. Water heater is 4 month old and under warranty. The homeowner is going to reach out to the original installer before he makes a decision on who is going to replace the gas valve and pilot assembly.


Paul T.

Paul T. Job Checkin

Came out today to inspect a thermal zone ac system that is not cooling properly. Model #Tcfl-hm3621cc, serial #W231526540. Upon arrival the homeowner stated that the system just won’t keep up. I was able to see Paul’s notes and he added 2 lbs of 410-a and an ez seal stick on 5/22/22 and the homeowner hasn’t had any issues until recently. I called for ac at the thermostat and observed the system starting normally. The temperature split is at a 10° differential. I connected my gauges and noticed that the system is low on 410-a refrigerant. I presented the homeowner with a solution. I filled the system per manufacturer specs with 410-a refrigerant and added half a uv dye stick. Chud will return in approximately 4 weeks to perform a leak investigation. Performed preventative maintenance for a Lennox ac system. Model #C26-41fc-1, serial #5800F17588. Upon arrival I turned the thermostat off. I powered down the furnace and removed the access panels. The evaporator coils are clean and in go


Thomas W.

Thomas W. Job Checkin

Performed preventative maintenance on a Coleman AC system. Model number: TC4B24. Serial number: W1M73666666. Upon arrival the unit was off. Turned the system on at the thermostat. Went to the unit and watched it run. Removed the panel to the evaporator coil. Inspected the coils for any dust build up. Poured water into the condensate trap and watched it drain properly. Poured water into the condensate pump and watched it pump out properly. Removed the panels to the the furnace. Checked the electrical connections to make sure they were properly secure. Checked the blower motor and fan for any dust build up. Changed the 16x25x5 filter supplied by the homeowner. Took an amp draw for the motor. Running within the manufacture’s specs. Placed the panels back on the unit and watched it run. Went outside to the condenser and watched it run. Checked the coils for any dirt build up. Removed the panel and brushed out any spiderwebs. Checked the contactor and capacitor. Both are running within the


Matthew M.

Matthew M. Job Checkin

Completed pm on ac. Customer is also purchasing 30 gallon water heater. See estimate. Collecting $1129


Shane A.

Shane A. Job Checkin

Model # GSX16S241AA Serial # 1906210614 Completed a preventative maintenance on a 3 year old Goodman air conditioner that we installed. I changed the 16x25x1 filter supplied by the customer. After that I took a split temperature reading and it was 18 degrees. I also made sure the condensate pump was working. After that I performed a amperage readings on the compressor 4.5 amps and the condenser fan motor was at .77 amps the capacitor and contactor are both operating properly. The system is operating properly at this time


Keith R.

Keith R. Job Checkin

Performed a 2nd floor dryer vent cleaning. Dryer vent,duct,flex duct and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 2 bedroom single system home. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Performed a 2nd floor dryer vent cleaning and reattached flex hose. Dryer vent, duct,flex duct and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Matthew M.

Matthew M. Job Checkin

Replace the OEM gas valve kit in the Coleman furnace (M# Tg8s100c16mp11, S# W1l8279859) under warranty. Once the repairs are made perform AC preventative maintenance Gas valve replacement and PMAC completed. System needed 2lbs of R410A. Cycled and tested, system working properly at this time.


Jonathan C.

Jonathan C. Job Checkin

Lennox air handler will need to be slide back 22 inches to be able to replace heat pack. High voltage wire will need to be extended with large junction box and 30 inches of 6/2 wire. System will need to be pumped down to extend line set, than pressure tested and vacuumed down to 500 microns. Custom return box will need to be ordered and made, size dimensions are in pictures. Custom supply plenum will need to be built by installers on site and wrapped in bubble wrap insulation. Drains will also need to be cut and extended. Coleman air handler will need to be slide back 12 inches to be able to replace heat pack if ever failed. (2) 10 inch round return pipes will need to be extended with 10 inch hard round pipe about 12 inches each and then wrapped in bubble wrap insulation. System does not need to be pumped down line set and high voltage wire should reach. Customer wants estimate to move Lennox air handler back by itself and than an estimate to move the Lennox and Coleman air handler b


Shane A.

Shane A. Job Checkin

Model # XC21-036-230-06 Serial # 5811F14762 Completed a preventative maintenance on a Lennox air conditioner. Customer changed out 16x25x4 filer. When I arrived I took a split temperature and it was 21 that tells me the refrigerant levels are good. Then I made sure the condensate pump is working. Then I went out and performed a amperage readings on the condenser fan motor running at .98 amps and the compressor running at 9.2 amps both are operating properly. Then I tested the capacitor it is not in range, I did replace the Capacitor. System is tested and operating properly at this time.


Thomas W.

Thomas W. Job Checkin

Performed preventative maintenance on a Lennox AC system. Model number: 13ACXN030-230-19. Serial number: 1916D61117. Upon arrival the system was off. I turned the system on at the thermostat. Went downstairs to the system and watched it run. Turned the system off at the switch. Removed the panel to the evaporator coil. Inspected the coils for any dust build up. Poured water into the condensate trap and watched it drain properly. Poured water into the condensate pump and watched it pump out properly. R roved the panels to the furnace. Checked the electrical connection to make sure they were properly secure. Checked the blower motor and fan for any dust build up. Replaced the 16x20x1 filter supplied by the homeowner. Took an amp draw of the motor. Running within the manufacture’s specs. Placed the panels back in the unit and watched it run. Went outside to the command watched it run. Checked th coils for any dirt build up. Removed the panel. Checked the Conan’s capacitor. Both are runnin


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a 3 year old Goodman heat pump. Model #GSZ140361 , serial #1905386612 . Upon arrival the homeowner had the system set to heat. I turned off the thermostat, powered down the air handler and removed the access panels. The evaporator coil’s are clean and in good condition. I tested the drain pan and drain line with several bottles of water to ensure that there are no leaks or clogs. I replaced the 16x20x1 air filter supplied by Chud. Checked all electrical connections to ensure that they are secure and in good condition. The blower motor and wheel are clean as well. I re attached the access panels and powered up the system. I called for ac and observed the system starting normally. The condenser coils are clean and in good condition. The condenser amp draws are .78 for the fan and 7.56 for the compressor. The temperature split is at a 21° differential. The system is operating properly at this time. 2 full system Chud Club Memberships Membership incl