1570 Old York Road
Abington, PA 19001
215-659-4343

Local Reviews
for norristown, pa

Rated 5.0 out of 5 stars based on 1 customer reviews

Great service

Very easy to set up an appointment. The technician was timely. He answered my questions & seemed knowledgeable


Response from Chud Air Conditioning & Heating:

Shelia, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for norristown, pa

Keith R.

Keith R. Job Checkin

Performed a 2nd floor dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Shane A.

Shane A. Job Checkin

Customer had no heat up stairs. The second floor zone valve was bad. I all purged the system to get maximum performance on the unit. System is operating properly at this point. No diagnostic fee customer is a USA member. System is 20 years old and should be replaced in the near future. Manufacturer Columbia Model # MCB100HID Serial # UFB24601


Amanda  F.

Amanda F. Job Checkin

Tankless water heater installation. Installed new unit to replace existing tanked heater so customer could have on-demand hot water. Advised on proper operation and maintenance. Carried off old water heater.


Keith R.

Keith R. Job Checkin

Performed a first floor dryer vent cleaning. Dryer vent, ductwork, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Matthew M.

Matthew M. Job Checkin

Installed carrier air handler and condenser. Adapted to existing ductwork, line set, and electrical. Replaced thermostat with eco bee. Replaced auxiliary pan and ran new pvc drain and traps to existing drain line. Flushed drain line. Flushed line set. Added new wet switch. Replaced power switch to air handler. Outside replaced disconnect box, whip, and pad. Replaced water heater with Bradford white 50gal gas hot water heater, and added st5 expansion tank. Adapted to existing plumbing and bled air out of all water lines. Cycled and tested, system working properly at this time. Filter size is 20x30x1


Frank B.

Frank B. Job Checkin

Performed preventative maintenance for 2 zone boiler system. Inspected all the electrical components. Confirmed proper high and low voltages. Cleaned the burners, burner assembly and burner compartment. Found the electronic damper not functioning but in manual mode so the boiler still functioning. Found the pressure/temperature not reading properly due to water infiltration as well as the auto fill which is meant to maintain the set water pressure without manually filling the system. System is 18-19 years old and has plenty of signs of rust/oxidation. System is fully operational but only in fair condition. In its current state even though fully functioning it possesses a failure risk. Recommend speaking with our comfort advisor to at least go over options for boiler , ac only and water heater even if not in the position to replace at this time. Performed a combustion analysis on the boiler. System is operating at 78.9% efficiency with a CO level of 32ppm. System is in fair condition an


Keith R.

Keith R. Job Checkin

Performed a 2nd floor dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Checked flex hose and ensured that it is secure. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a carrier air handler. The evaporator coil’s are clean and in good condition. Tested the drain pan and drain line with several bottles of water to ensure that there are no leaks or clogs. Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. The air filter was recently replaced by the homeowner size 20x30x1. The blower motor amp draw is within normal range. The temperature split is at a 20. The condenser coils are clean and in good condition. The condenser amp draws are .61 for the fan and 8.9 for the compressor. The refrigerant pressures are 88/175. These are normal readings for r-22 refrigerant with an ambient temperature of 58°. The system is operating properly at this time.


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation. All vents and ductwork are clear of dust and debris at this time. Unit is functioning properly at this time but condensate pump drain is clogged. Maintenance is aware of the situation. Recommend duct cleaning every 3-4 years. Thank you for your business! This is a billout.


Paul A.

Paul A. Job Checkin

No heat. Newer unit. Inducer motor not running. Pulled assembly from unit and removed a critter from the flue inside of the unit. Started system for normal operation and it is currently operating properly at this time.


Paul A.

Paul A. Job Checkin

No heat call. Numerous replacement limit control replaced. Found a brand new limit in place. After starting the unit if was off on limit again. Bypassed limit to perform a combustion analysis. The CO PPM was well over 2000 before I shut the analyzer off to prevent damage. Burn marks on exterior grill and loose gas valve connections inside the unit. I disconnected gas from the utility closet and shut the breaker off in the apartment. Unit will need to be replaced. Pictures and a brief description of diagnostic has been emailed to Jane.


Paul A.

Paul A. Job Checkin

No heat call. Found unit not igniting properly on a call for heat. Removed the ignitor and tested resistance and determined the part had failed. Installed a customer supplied replacement ignitor and was able to get the unit operating properly. Cycled and tested several times. System is now operating properly.


Paul A.

Paul A. Job Checkin

No heat call. Unit was miswired and had to contact National Comfort technical department since the schematic was worn off of the unit. Corrected wiring issues including one leg of power connected to the load switching side of the single pole contactor. Had to install a new contactor due to existing being pitted. The system fan worked in air conditioning, Just not for fan only and heat. The system is now working correctly and tested for proper operation.


Matthew M.

Matthew M. Job Checkin

Completed transition from supply plenum to supply trunk. Attempted start up and discovered red thermostat wire was shorted out. Used green fan wire in its place. Management is aware of the situation. Will leave system wired as is, alternative is to pull new low voltage wire to thermostat. Cycled and tested, system working properly at this time. Bill out.


Matthew M.

Matthew M. Job Checkin

Bill out