Needed to replace hwh expansion tank. Wonderful office with scheduling and accommodating to situation. Tech was excellent - as always!!
Response from Chud Air Conditioning & Heating:
We’re so grateful for your 5-star review. We strive to offer the best experience possible, and your review tells us we’re doing it right!
As always, excellent service! Hard to come by these days…highly recommended.
Response from Chud Air Conditioning & Heating:
Thank you for sharing your experience Mitchell & Catherine, everyone at Chud appreciates it!
Chud just installed a humidifier in my home. Tech Shane excellent once again! Very happy with chud - thank you to the entire staff - Highly recommended!
Response from Chud Air Conditioning & Heating:
Catherine, thank you for the raving review! It truly means a lot to the Chud team.
Keith from chud did our dryer vent cleaning - outstanding service! Knowledgeable and accommodating - highly recommended!
Response from Chud Air Conditioning & Heating:
Thank you for the amazing 5-star review!
Good job
Response from Chud Air Conditioning & Heating:
Chales, thank you for leaving Chud a 5 star review!
Had an unexpected time critical situation - Chud went above and beyond for excellent service! Many thanks to Amanda - and tech Shane!! Highly recommended!
Response from Chud Air Conditioning & Heating:
Catherine, we’ll make sure to pass your kind words along to Amanda & Shane, who we know will be delighted to read your comments.
Response from Chud Air Conditioning & Heating:
Joanne, thank you for the 5 star review!
Sebastian and chud staff provided excellent service from start to finish! Highly recommended to all!
Response from Chud Air Conditioning & Heating:
Cathy & Mitchell, thank you for the kind words and 5 star review! The Chud team appreciates it.
Pleasant and would like Frank to service all the time
Response from Chud Air Conditioning & Heating:
Thank you for the 5 star review Gail & Gordon. It truly means a lot to the Chud team!
Would definitely recommend
Response from Chud Air Conditioning & Heating:
Thank you for the 5 star review Rachel. Everyone at Chud appreciates it.
Response from Chud Air Conditioning & Heating:
Thank you for the 5 star review Kevin. Everyone at Chud appreciates it!
Response from Chud Air Conditioning & Heating:
5 stars, thanks Felecia!
Performed a 2nd floor dryer vent cleaning. Dryer vent, duct, flex duct and lint trap are all clear of lint and debris at this time. Dryer and booster fan are functioning properly at this time. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!
Performed preventative maintenance on a CARRIER AC unit. Model number: CH14NB060-A. Serial number: 3818X49825. Upon arrival the system was off at the thermostat. I turned the system in at the thermostat and went upstairs and watched the unit run. I turned the unit off at the switch. Removed the panel to the evaporator coil. Inspected the coil for any dust build up. Poured water into the condensate trap and watched the water drain properly. Inspected the gravity drain and watched the water drain through. I removed the panels to the furnace and checked the blower motor and fan for any dust build up. Checked the capacitor to the blower motor. Running within manufacture’s specs. Checked all electrical connections to make sure they were properly secure. Filter was replaced in march of 2023. Still good until next year. Took an amp draw of the motor, 9.5 amps. Placed panels back on unit. Went outside to the condenser and watched the unit run. Checked the coils for any dirt build up. Removed t
Bradford white Model # RG1PV50S6X19 Serial # WJ46628081 Installed new #5 expansion tank. Also installed new Taco leak breaker. Tested system and water heater is working and leak free.
Manufacturer Carrier Model # CH14NB060P0GAAAA Serial # 4120X48092 Completed a preventative maintenance on a carrier air conditioner. Temperature split was 20. Customer changed 20x25x4 filter. Performed a amperage readings on the compressor and condenser fan motor both are operating properly. Cleaned out drain line also made sure evaporator coil was draining. System is operating properly. Customer has a failed expansion tank. See estimate for details. Remaining Balance 299.35 system is operating properly at this time.
Carrier Model # CH14N06000GAAAA Serial # 0820X41095 Completed a preventative maintenance on a 2 year old carrier unit. Did a temperature split it was 20 degrees also, did a amp check on the condenser fan motor and compressor, both are operating properly. Made sure unit was draining. Capacitor is in range of its specs. System is operating properly at this point. Filter size 16x25x4
Installed new Aprilaire power fan humidifier. Added new 1/4 inch hot water line and 120 volt receptacle to power humidifier. Added new custom overflow safety pan with float switch under humidifier in case of a leak because system is located on second floor. Ran new 3/4 inch pvc drain line that is also tied in with a drain from the new overflow safety pan. Noticed that ST 5 expansion tank on water heater had failed. Replaced with new ST 5 expansion tank and properly braced tank up incase of failure in the future. Tested and cycled humidifier and it is operating properly at this time.
Humidifier installed with 5 years cleanings Water safety underneath the Humidifier 5 yr membership on Ac & ht and filters
Installed new 700m power vent humidifier.project including running a new 1/4 “ water line. Installed new high voltage outlet with transformer. Ran all new low voltage wiring. Installed new drain line. I tested the system to make sure it was draining properly and it was. I also, made sure the humidifier was working in heat pump mode, and when it is using the furnace for emergency heat. System is operating properly at this time. M#59SC2D100E211120 s#0920A57636
Did a maintenance on a duel fuel system. Did a combustion test the ppm was 34 and the o2 was 11. Cleaned the flame sensor did a amp check on the blower motor and inducer motor. Both are in range. Also checked temperature an pressures on the heat pump and did a amp check on the fan motor and compressor. Cleaned drain the the high efficiency furnace. Changed out the 16x25x1 filter system is operating properly at this time. m# 59SC2C100S211120 S#3818A63046 customer would like a maintenance agreement she said she would mail check to the office for it.
Performed a 2nd floor dryer vent cleaning. Dryer vent, duct, flex hose, lint trap and wall mounted lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!
Performed preventative maintenance for a dual fuel system. Home contains a heat pump with a high efficiency propane fueled furnace. Inspected all the electrical components. Confirmed proper high and low voltages. Customer replaces the Merv 11 16x25x5 air filter and power humidifier water panel. Cleaned the burners, flame sensor and burner compartment. Performed a combustion analysis on the furnace. System is operating at 95% efficiency with a CO level of 10ppm. Tested the heat pump and it had a temperature difference of 31°. Last time I was out here customer had a gas issue that has seemed to be resolved by the gas company replacing the gas meter. Tested the amp draw for thr blower, inducer, compressor and fan motor. All were operating within the manufacturer specifications. System is operating properly at this time.
Did a maintenance on a dual fuel system during the maintenance I checked the heat pump outside I put my gauges on and the temperatures and pressures of the refrigerant were in range of the unit. And on the inside of the furnace I clean the flame sensor I cleaned out the burner box and the blower motor housing. Also clean the flame sensor did a combustion test which checks out. Upon arriving to the house the customer called in saying she had water and the unit was not working so I dried the wet switch and the system kicked right on and the customer had already cleaned up the water. Somehow the high-efficiency drain on the furnace came out of the PVC pipe that drains to the sink. So to prevent that from happening again I put a clamp on to the PVC drain. System is operating properly at this time the furnace and the heat pump.M#59SC2D100E211120 s#0920A57636
Performed air duct cleaning and sanitation on a 3 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business! This was free with install
Installed new Goodman equipment. Project included new condenser pad with heat pump risers. Installed new high voltage disconnect box with new high voltage wire. Ran new copper refrigerant lines. Adapted to supply, installed new return box with new return drop. With 16x20x1 filter. Ran new drain lines adapted to high voltage and low voltage. With 9.5 kw heat kit. Reused thermostat. System is tested and working properly at this time.
Came out today for a York rtu leaking. Upon inspection I found that the system was leaking in the drop ceiling next to the return duct. I opened the return ducts and found two 20x20x1 air filters severely clogged. I replaced the filters and made my way to the roof. The system was operating when I got up there. I opened the panels and attached my gauges. This is a York package rooftop unit model #D3cg072n09925a, serial #N0h6785693. The system seemed to be extremely low on R-22 refrigerant. Low side pressure was at 65. The amp draw for the compressor is at 22. The system is rated for 18 amps. The fan seized up before I had a chance to take an amp draw. The system is 18 years old and the refrigerant is low, the fan motor seized and the compressor is pulling a high amp draw. With all these issues combined my recommendation is to update the system to one that utilizes 410-a refrigerant. Bill out per office.