Very polite and knowledgeable
Response from Chud Air Conditioning & Heating:
Bill, thank you for leaving Chud a 5 star review!
Excellent service.
Response from Chud Air Conditioning & Heating:
Mike, thank you for the 5 star review!
Response from Chud Air Conditioning & Heating:
Thank you for the 5 star review Frank!
Great job on replacement of condenser on a heat pump.
Response from Chud Air Conditioning & Heating:
Thank you for the 5 stars Bill!
Customer had scheduled a full duct cleaning for their HVAC system. Cleaned out all the duct work throughout the home, visually inspected for leaks or damaged sections. Customer noted they saw an immediate improvement in airflow, particularly in sections of the house where it had been very limited prior.
Performed air duct cleaning and sanitation on a 4 bedroom 2 system house. All vents and ductwork are clear of dust and debris at this time. Both systems are functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!
Summary: Performed preventative maintenance for a aire-flo heat pump. Observed the system starting normally. Blower motor amp draw is 2.1. The heat coils are in good condition. Supply temp is 160 and still rising. Checked all electrical components needed for heating. 3 Zone electronic zone dampers with zone controller are working as designed. Witnessed system run a defrost cycle which proves sensor and defrost works as designed. Replaced the space guard 501 air filter. Recommend updating the air cleaner due to filter frame in poor shape. Parts on the filter housing were broken and the design is outdated. Attached will be an estimate for new media air cleaner. Checked the heat pump unit. Heat pump is free of any buildup on the coils. Amp draws are 9.4Amfor the compressor and .8Amfor the fan. Refrigerant pressures are within normal range. The system is operating properly at this time.
Performed preventative maintenance for high efficiency furnace. Cleaned the burners, flame sensor and burner compartment. Inspected all the electrical components. Customer replaced the Merv 11 air filter. Confirmed proper high and low voltages. Tested the amp draw for the blower and inducer. Both are operating within the manufacturer specs. Made sure all tubing was clear from the pressure switch and collector box. This furnace runs on LP gas. Performed a humidifier service on an Aprilaire bypass humidifier. Replaced the #35 water panel. Performed a combustion analysis on the furnace. System is operating at 95.3% efficiency with a CO level of 22ppm. System is operating properly at this time. Model #G32V5-125-5 Serial #5803G53601
M#TM9V120D20MP11CA s#W1B8571107. Did a maintenance on a gas furnace. During the maintenance I clean the flame sensor. Also did a combustion analyzer test test the CO level was seven and the O2 level was 18.2 also cleaned out the burner rack and the blower motor housing. Also did an Amp on the inducer motor and the blower motor which both meet the furnace specs.. customer switched out 20 x 25 x 1 filter. System is operating properly at this point. M#GMEC800603BN s#1911054361 did a maintenance only Goodman gas furnace During the maintenance I clean the flame sensor. Also cleaned out the burner box and the blower motor housing is a combustion analyzer test which check the system is only 2 years old. Also did an amp check on the inducer motor and blower motor. And also changed out the customer supplied 14 x 30 x 1 filter.
Do the maintenance on a heat pump. During the maintenance I made sure that the drain lines were clear and draining properly. Also checked temperatures and pressures outside by the condenser and everything checked out. Did an amp reading on the heat pack to ensure that it is working. Customer swap filter. I clean the blower motor housing.customer has really old humidifier I would recommend to replace it. System is operating properly at this time. M#Fcm4x6000al s#A150283557
Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!
Performed preventative maintenance for a Goodman heat pump system model #GSZ160361BD, serial #2011712120. The evaporator coil’s are clean and in good condition. Tested the drain pan, drain line and condensate pump with several cups of hot water to ensure that there are no leaks or clogs in the system. Replaced the Merv11 air filter size 16x25x5 (chud supplied). Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. The blower motor amp draw is at 3.1. The temperature split is at a 19. The condenser coils are clean and in good condition. The condenser amp draws are 8.7 for the compressor and .67 for the fan. The refrigerant pressures are within normal range for the temperature outside today. The system is operating properly at this time.
Performed preventative maintenance on 2 AC systems. (Extension unit/Air handler/Just AC) Customer replaced 20x25x1 air filter prior to us coming out. Tested evaporator coil pan and condensate line for proper drainage. Temperature split is at 20° with a supply air temperature of 48°. This unit has the correct refrigerant charge. Compressor-9.1 RLA Condenser fan motor-1.7 FLA . Both of these readings are within the amperage rating for this unit. System is operating properly at this time and is ready for the summer season. Coleman condenser- S#W1D9830067 M#CC7B4221SA Filter size- 20x25x1 (Main house unit/Heat and AC) Replaced 14x30x1 air filter prior to us coming out. Tested evaporator coil pan and condensate line for proper drainage. Temperature split is at 18° with a supply air temperature of 51°. This unit has the correct refrigerant charge. Compressor-5.5 RLA Condenser fan motor-0.6 FLA . Both of these readings are within the amperage rating for this unit. System is operating p
Performed preventative maintenance for heat pump system. This was an air conditioning maintenance for a heat pump system. Replaced the customer supplied air filter (20x20x1). Inspected all the electrical components. Confirmed proper high and low voltages. Tested the temperature split between the supply and return. System is operating at a 20° differential at a current temperature of 70°. Inspected the gravity drain for any blockage. Found some debris in the drain and was able to pick it out of the clean out tee. Tested the amp draw of the blower, compressor and fan motor. All were operating within the manufacturer specs. The pipe the customer had concerns about is a partially rusted supply duct. This is partially rusted due to the water shut off valve for the outdoor hose hook up. The packing nut on the valve just needs to be tightened. I also found a water regulator with a minor leak. Let customer know to call his water company for repair/replacement of the regulator since it’s on the
Replaced the Lennox I comfort thermostat with a new s30 I comfort thermostat. Connected all the proper wires and tested the system for ac and heat. I also helped the homeowner connect to his mobile device. The system is operating properly at this time. I comfort thermostat serial #kk21k06f7w.
Removed thermostat from wall to return back to Lennox.
Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Performed dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!
Performed preventative maintenance for a arcoaire heat pump. The evaporator coil’s are clean and in good condition. Tested the drain pan and drain line with several bottles of water to ensure that there are no leaks or clogs. The homeowner stated that he noticed some water leaking out of the bottom of the system. Upon inspection I found that the drain pan for the evaporator coil’s only goes around the edges of the coil and isn’t a full pan. I believe this is just a design flaw by the manufacturer. See photos for reference. Homeowner recently replaced the air filter size 20x20x4 Merv12. Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. The blower motor amp draw is 3.9. The temperature split is at a 19. The condenser coil’s are clean and in good condition. The condenser amp draws are .72 for the fan and 15.1 for the compressor. The refrigerant pressures are 126/285. These are normal