Furnace and humidifier annual check

Excellent service.


Response from Chud Air Conditioning & Heating:

Mike, thank you for the 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Frank!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional and caring about the service.

Great job on replacement of condenser on a heat pump.


Response from Chud Air Conditioning & Heating:

Thank you for the 5 stars Bill!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for richboro, pa

Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a Goodman heat pump system model #GSZ160361BD, serial #2011712120. The evaporator coil’s are clean and in good condition. Tested the drain pan, drain line and condensate pump with several cups of hot water to ensure that there are no leaks or clogs in the system. Replaced the Merv11 air filter size 16x25x5 (chud supplied). Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. The blower motor amp draw is at 3.1. The temperature split is at a 19. The condenser coils are clean and in good condition. The condenser amp draws are 8.7 for the compressor and .67 for the fan. The refrigerant pressures are within normal range for the temperature outside today. The system is operating properly at this time.


Sebastian R.

Sebastian R. Job Checkin

Performed preventative maintenance on 2 AC systems. (Extension unit/Air handler/Just AC) Customer replaced 20x25x1 air filter prior to us coming out. Tested evaporator coil pan and condensate line for proper drainage. Temperature split is at 20° with a supply air temperature of 48°. This unit has the correct refrigerant charge. Compressor-9.1 RLA Condenser fan motor-1.7 FLA . Both of these readings are within the amperage rating for this unit. System is operating properly at this time and is ready for the summer season. Coleman condenser- S#W1D9830067 M#CC7B4221SA Filter size- 20x25x1 (Main house unit/Heat and AC) Replaced 14x30x1 air filter prior to us coming out. Tested evaporator coil pan and condensate line for proper drainage. Temperature split is at 18° with a supply air temperature of 51°. This unit has the correct refrigerant charge. Compressor-5.5 RLA Condenser fan motor-0.6 FLA . Both of these readings are within the amperage rating for this unit. System is operating p


Frank B.

Frank B. Job Checkin

Performed preventative maintenance for heat pump system. This was an air conditioning maintenance for a heat pump system. Replaced the customer supplied air filter (20x20x1). Inspected all the electrical components. Confirmed proper high and low voltages. Tested the temperature split between the supply and return. System is operating at a 20° differential at a current temperature of 70°. Inspected the gravity drain for any blockage. Found some debris in the drain and was able to pick it out of the clean out tee. Tested the amp draw of the blower, compressor and fan motor. All were operating within the manufacturer specs. The pipe the customer had concerns about is a partially rusted supply duct. This is partially rusted due to the water shut off valve for the outdoor hose hook up. The packing nut on the valve just needs to be tightened. I also found a water regulator with a minor leak. Let customer know to call his water company for repair/replacement of the regulator since it’s on the


Paul T.

Paul T. Job Checkin

Replaced the Lennox I comfort thermostat with a new s30 I comfort thermostat. Connected all the proper wires and tested the system for ac and heat. I also helped the homeowner connect to his mobile device. The system is operating properly at this time. I comfort thermostat serial #kk21k06f7w.


Sebastian R.

Sebastian R. Job Checkin

Removed thermostat from wall to return back to Lennox.


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Performed dryer vent cleaning. Dryer vent, duct, flex hose and lint trap are all clear of lint and debris at this time. Dryer is functioning properly at this time and exhaust flow is optimal. Recommend dryer vent cleaning every 1-2 years. Thank you for your business!


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a arcoaire heat pump. The evaporator coil’s are clean and in good condition. Tested the drain pan and drain line with several bottles of water to ensure that there are no leaks or clogs. The homeowner stated that he noticed some water leaking out of the bottom of the system. Upon inspection I found that the drain pan for the evaporator coil’s only goes around the edges of the coil and isn’t a full pan. I believe this is just a design flaw by the manufacturer. See photos for reference. Homeowner recently replaced the air filter size 20x20x4 Merv12. Checked all electrical components needed for air conditioning to ensure that they are secure and in good condition. The blower motor amp draw is 3.9. The temperature split is at a 19. The condenser coil’s are clean and in good condition. The condenser amp draws are .72 for the fan and 15.1 for the compressor. The refrigerant pressures are 126/285. These are normal


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation on a 4 bedroom single system house. All vents and ductwork are clear of dust and debris at this time. System is functioning properly at this time. Recommend duct cleaning every 3-4 years. Thank you for your business!


Keith R.

Keith R. Job Checkin

Performed air duct cleaning and sanitation. All vents and ductwork are clear of dust and debris at this time. Unit is functioning properly at this time. Recommend duct cleaning every 2-3 years. Thank you for your business!


Frank B.

Frank B. Job Checkin

Preventative maintenance check up on Lennox HVAC system for heating season. Tested drains and replaced customer supplied air filter (18x20x1), inspected indoor and outdoor coils. Tested voltage and amperage readings on all components. Confirmed proper high and low voltages. Tested the electric heat kit for proper heating. System is operating properly and ready for the season.


Paul A.

Paul A. Job Checkin

Removed a defective Lennox 18 SEER outdoor heat pump and installed gratis unit from Lennox. Installed unit per proper refrigeration practices. Tested unit first in air conditioning mode and recorded 10 degrees of subcooling and 14 degrees of superheat. Turned unit on for heat and verified that unit is operating properly. Old unit will be returned to our office and we will return the old unit to Lennox.


Paul A.

Paul A. Job Checkin

Return visit with Lennox field representative to access issues with high efficiency Lennox outdoor heat pump. Performed different diagnostic testing and determined the compressor is not pumping. There may also be an issue with the expansion valve based on previously stored diagnostic codes. Based on these “major” failures with a new piece of equipment, Lennox is going to follow up with us to let us know what the next step is. N/C, WARRANTY for diagnostic work today. ***PA will be in contact with the dealer and follow up with homeowner.*** ***Parts “22F37” and “11Y29” will need an RGA slip and need to be returned to Lennox Bensalem.*** M#EL18XPV-036-230A01, S#5821C15561.


Paul A.

Paul A. Job Checkin

Follow up visit following diagnostic work performed by Paul T. Went through necessary diagnostic steps under the guidance of Lennox field supervisor. Determined that the unitary/modulating control board must be replaced first in order to complete further diagnostic work. During the follow up visit, we are going to try and coordinate for Lennox field representative to be on site due to previous issues with this system. See estimates for follow up details.


Paul T.

Paul T. Job Checkin

Came out today for a heat pump not operating properly. I called for heat and noticed that the suction line is ice cold. I went to the condenser and saw an error code 429-inverter has detected a dc link low voltage condition. If this occurs 10 times during a one hour period, the outdoor unit is locked out. I then cut all power to the system to try and reset the system. I turned the system back on and got the same results. I then reached out to PA and he gave me some other trouble shooting ideas. I went through trouble shooting with PA with no success. I then tried to run the AC to get a superheat and subcool reading but the system would not run. PA will return to do further diagnosis.


Paul A.

Paul A. Job Checkin

1. Performed preventative maintenance on Coleman Gas Furnace. Homeowner addressed that he had already replaced 20x25x1 air filters just a couple weeks ago as they look in good condition. Completed combustion analysis and CO PPM 0. Cleaned and inspected burners, flame sensor and blower compartment. Verified proper amperage on motors. System is working properly and ready for the season! 2. Performed preventative maintained on Goodman Furnace Heat Pump. Homeowner addressed that he had already replaced 14x30x1 air filter just a couple weeks ago as it looks in good condition. Checked both indoor and outdoor unit and are working properly. System is ready for the season!