1570 Old York Road
Abington, PA 19001
215-659-4343

Our Top Cities


Local Reviews
for warminster, pa

Rated 5.0 out of 5 stars based on 44 customer reviews

Shane was professional, efficient and thorough!

Very professional!


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Rick, everyone at Chud appreciates it!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very comprehensive and explained all aspects of service call. Fp.


Response from Chud Air Conditioning & Heating:

Frank & Joyce, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Customer

Professional technician, friendly and efficient


Response from Chud Air Conditioning & Heating:

5 stars, thank you Phillip & Laura.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Reliable


Response from Chud Air Conditioning & Heating:

William & Mildred, thank you for leaving Chud a 5 star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service wonderful installers

Both of the installers were great. They were both very polite and did a great job


Response from Chud Air Conditioning & Heating:

Robert, we’ll make sure to pass your kind words along to John & Matt, who we know will be delighted to read your comments.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful

Keith was right on time. He and his partner were very courteous and friendly


Response from Chud Air Conditioning & Heating:

5 stars, thank you Robert!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Retired chemist.

Paul did a great job on both the heating system and the mini-split.


Response from Chud Air Conditioning & Heating:

David & Mary, thank you for the 5 star review, we are grateful that you chose Chud.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Keith was super friendly and the dryer vent problem is fixed and thank you !


Response from Chud Air Conditioning & Heating:

Maryann, I'm so glad we could help! Thank you for leaving Chud a 5 star review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Tara. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from Chud Air Conditioning & Heating:

5 stars, thank you Rachel!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great honest service


Response from Chud Air Conditioning & Heating:

Thank you for the 5 star review Rachel. It truly means a lot to the Chud team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

The best service ever


Response from Chud Air Conditioning & Heating:

The team here at Chud loves to see 5 star reviews! Thank you Irene.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

We had our vents and duct work cleaned. The employees were very friendly and extremely polite. They worked in a professional manner. I am very happy with the results.


Response from Chud Air Conditioning & Heating:

Susan, thank you for the 5 star review, we are grateful that you chose Chud!

  • Overall Experience
  • Quality
  • Price
  • Convenience

1 Year Free checkup service

Prompt, Friendly and Courteous Service from Sebastian Riveria. Very happy with the well trained service we received. Highly satisfied with the install and service from Chud.


Response from Chud Air Conditioning & Heating:

Thank you for sharing your experience Anthony, the Chud team appreciates it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

He was great and very personable.

He was great, right on time. He was very considerate of our home. He was very personable. I feel he is an asset to your organizatio


Response from Chud Air Conditioning & Heating:

Thank you for the wonderful review and for taking the time to share your feedback.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for warminster, pa

shane@chudcompany.com

shane@chudcompany.com Job Checkin

Showed up to a no heat Call. Error code 5 showed up failure to ignite. System is under warranty per Paul Ash we will need to order gas valve, pressure switch, new flame sensor. S#5917H03356 m#EL180DF070E36B-02


shane@chudcompany.com

shane@chudcompany.com Job Checkin

Want to A no heat call. Arrive to the house in the heater was working turn system all cleared out and do support change to customer supplied filter clean the flame sensor. Went through the thermostat to make sure it was programmed right. I did not collect payment due to we were out for a maintenance this month and we were also here the other week and replace the thermostat in the same issue is occurring but while I was there the furnace was operating properly. m#EL180DF070E36B-02 s#5917H03356


Paul A.

Paul A. Job Checkin

On arrival found the system start and observed the outdoor fan motor spinning at a very slow rate. Checked capacitor reading and found that it was well below rated 40/5 MFD. Disconnected low voltage and observed contactor “sticking” as well. Advised homeowner that these parts needed to be changed first to move forward with the preventative maintenance. After repairs, observed condenser fan motor drawing 0.6 amps which is above nameplate (0.5 FLA). Compressor amperage 6.9, rated (14.1 RLA). The indoor unit blower wheel has a slight rattle to it. Pulled blower assembly to inspect for any defects. The wheel is likely off balance slightly which is to be expected on a 2013 heat pump system. Homeowner replaced the 16x20x1 air filter. All(3) banks of the electric heat pack are functional and reading 19.8 amps per bank. Overall, given the parts that could fail Chud will provide a quote to address the outdoor fan motor and fan blade. We can also provide a FREE estimate to upgrade the system a


Paul A.

Paul A. Job Checkin

Did a no heat call on a Lenox gas furnace. Arriving to the job I heard the inducer motor humming. So I undid the flue pipe and made sure the inducer motor was Spinning freely which it was not due to dust and debris in there. After cleaning that out and making sure the inducer motor was spinning freely the unit started right up and is working properly at this point. M#SL280UH090XV48B-05 s#1718H53931


Frank B.

Frank B. Job Checkin

Performed preventative maintenance for a 3 zone boiler system. Inspected all the electrical components. Confirmed proper high and low voltages. Boiler is a New Yorker model from 2011. Includes, 3 zone panel with 3 circulators, auto fill and newer expansion tank. Systems water pressure was at 20psi on arrival. Found no air in the 3rd floor radiators. Found a couple radiator valves in the off position to which I turned them on for even heat. House had an addition put on from previous owners in the back of the house. This is where baseboards were added. The majority of the house ran by the dining room thermostat. Cleaned the burners and burner compartment. Performed a combustion analysis on the boiler. System is operating at 81.4% efficiency with a CO level of 24ppm. Customer would like to updated the thermostats to be programmable. Attached will be the pricing that customer requested. Thermostats have to operate on batteries since the current ones only have control voltage without a comm


Paul T.

Paul T. Job Checkin

Came out today for a no heat call. Upon arrival the homeowner stated that the system runs on a schedule but this morning it was under the desired temperature and the thermostat said recovery mode. I powered the system up and called for heat I observed the system starting normally and once it reached the desired temperature the system shut down. I explained to the homeowner that based on the information she is giving me and from what I’m seeing it is my opinion that either the batteries in the thermostat are bad of the thermostat is defective. After giving it some thought the homeowner opted to replace the thermostat. I replaced the old thermostat with a new Honeywell t4 thermostat serial #2213jjb48078. After the installation I tested the system by calling for heat and ac. The system is operating properly at this time.


Paul A.

Paul A. Job Checkin

Did a preventative maintenance on a old gas furnace. System is older and will need to be replaced soon. During the maintenance I cleaned out the burner box inspected the igniter. Also cleaned out the burner box and switched out the 16 x 25 x 1 filter. Also did a combustion test the CO level was for the O2 level was 16.2. I also added out the blower motor and the inducer motor works we’re both on the higher side but range of the furnace. Checked all other electrical connections to make sure they were tight Secure. Also recommending a new water heater because the other one is from 1996 and needs to re-replaced immediately. System is operating properly at this point. M#H8MPN100F14A1 s#A034103657


Paul A.

Paul A. Job Checkin

Did they maintenance on a high-efficiency gas furnace. During the maintenance I did a combustion test the CO level was nine and the O2 level was 19.2. I also clean the flame sensor and cleaned out the burner rack. Also cleaned out the blower motor housing. Also did an amp draw on the inducer motor and the blower motor which are both running within furnace specs. Also I poured water down the high efficiency furnace drain to make sure that the trap was not clogged and that it was draining properly. Also did a humidifier service where I wipe down the whole entire humidifier changed out the number 35 panel and also made sure it was draining properly which it was. Filter size 16 x 25 x 1. System is operating properly at this point. M#58MCB100-16 s#58MCB100—-11116.


Paul A.

Paul A. Job Checkin

Did a preventative maintenance on a train gas furnace. Clean the flame sensor. Did an amperage draw on the inducer motor and the blower motor the inducer motor was a little high for my liking but was in the range of the furnace specs. Cleaned out the burner compartment and the blower housing. Did a combustion test the CO was seven and the O2 was 14. Cleaned out the drain for the high-efficiency furnace and made sure the condensate pump was working.M#TUX1B080A9421AB s#7165SH67G


Paul A.

Paul A. Job Checkin

Did a preventative maintenance on a Lennox gas furnace. During the maintenance I clean the flame sensor. Also, I cleaned out the burner box and the blower motor housing. I also did an amperage check on the inducer motor and the blower motor which both need the furnace specs. I also cleaned out the inducer port. I also shop vac to return out due to a lot of contractor dust due to this I’m gonna recommend a duct cleaning. Also did a carbon monoxide check the CO level was 49.4 and the O2 level was 11.2. Changed out to 16 x 25x1 filter. System Is operating properly at this point. I am also going to recommend a REME-halo to increase air quality.M#ML180UH090P36B-53 s#1715E14582


Paul A.

Paul A. Job Checkin

Did a maintenance on a gas furnace. Cleaned off the flame sensor also cleaned out the back burner compartment and the blower motor housing. Swapped out to 16 x 20 x 1 filter. Did a combustion test Co level was 49 and the O2 level was 11.2. Also do the amp reading on the inducer motor and blower motor does meet the furnace spec sheet. System is operating properly at this point. M#KG7SA 090C-24B1 s#KGG170709407


Matthew M.

Matthew M. Job Checkin

Completed preventative maintenance on high efficiency furnace. Replaced filter. Checked all necessary components for acceptable range and proper performance. Flushed condensate drain to check for any clogs. No clogs at this time. Cycled and tested, system working properly at this time. No charge.


Paul A.

Paul A. Job Checkin

Did a preventative maintenance on a Lennox unit gas furnace. During the maintenance I clean the flame sensor cleared out the pressure switch port. Also did an amp reading on the inducer motor and the blower motor. I cleaned out the burner compartment as well as the blower motor. The supplied temp was 113°. Swapped out the filter which is 16 x 25 x 1. I system is running properly at this point in time. m#SL280UH110V60C-03 s#5911L23436.


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a Lennox furnace model #SL280UH090V36B-03, serial #5915E14212. I powered the system down and removed the access panels. I removed and cleaned carbon off of the flame sensor and cleaned out the burners and burner box. The homeowner supplied her own pure air kit however the homeowner bought the wrong size. The homeowner had some spare uv bulbs that I replaced and I installed a 16x25x1 air filter until the homeowner can get the correct Merv air filter. I checked the pressure switch for clogs and tested the drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. I checked all electrical connections to ensure that they are secure and in good condition. I powered the system back up and called for heat. I took a combustion analysis test and received the following readings, o2 is at 12.2% and the co levels are 5ppm. The inducer motor amp draw is at .21 and the blower motor amp draw is at 4.6. The system is


Paul T.

Paul T. Job Checkin

Performed preventative maintenance for a Lennox furnace model #EL280UH090E36B-01, serial #5919K18008. I powered the system down and removed the access panels. Removed and cleaned carbon off of the flame sensor and cleaned out the burners and burner box. The homeowner recently replaced the air filter size 16x25x1. Checked all electrical connections to ensure that they are secure and in good condition. Checked the pressure switch for clogs. I powered the system back up and called for heat. Took a combustion analysis test and received the following readings, o2 is at 12.0% and the co levels are 13ppm. The inducer motor amp draw is at .13 and the blower motor amp draw is at 4.4. The system is operating properly at this time.