1276 N. Warson
St. Louis, MO 63132
(314) 352-1111

Local Reviews
for ballwin, mo

Rated 4.9 out of 5 stars based on 160 customer reviews

Great Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very thorough and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

All is good

  • Overall Experience
  • Quality
  • Price
  • Convenience

Again, Jeff did an excellent job for us

Jeff replaced the coil on our air conditioner very recently. He came back to check everything and to clean the outside unit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great job!

Jeff and Classic Aire did a wonderful job for us. We needed a new coil. Jeff spent over 4 hours getting the damaged coil out and the new coil installed. Throughout the process, he was good-natured and pleasant. I am impressed with the way Classic Aire calls when they say they will and lets us know when when the technician is on the way. thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent response time

Had a service Interruption on one of the holidays and service response was within 3 to 4 hours.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very impressed with John Murphy

The new travel video is very impressive! I don't know how costly this service is but it sure is helpful in knowing when the person will arrive.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very thorough

Professional work. Spent the time to do a good job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service rating

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

You guys are always the best!!!

Always the best experiences with this company. Honest, transparent, and easy to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great & friendly service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very pleased

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very good

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

The service was very thorough and the technician was professional and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for ballwin, mo

John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Tr41. Adjust Blower: 2.3A. Inducer: 1.03A. Adjust Gas pressure: 3.5 inches water column. Temperature rise: 55 . Supply: 122. Return: 67 . Found basement pressure negative (-.01 inches water column) due to leaks in return-air ducting. This is causing downdraft of flu and fluegas spillage at water heater. Suggestions: recommend installing make-up air venting into basement from first floor.


John M.

John M. Job Checkin

Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Replaced air filter. Customer complained of banging noise at times when system turns on. No noises found at this time. I found damper in first floor duct not closing. Damper was hitting mounting screws. I replaced with shorter mounting screws. Clean and check humidifier, replace pad, checked water flow and drain. Solenoid valve not opening. Replaced solenoid valve. Replaced UV lamp for APCO air purifier. Checked blower speeds. Setup furnace for two stage operation.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced air filter. Clean and check humidifier, replace pad, checked water flow and drain. 8.4uA. Blower: 3.1A . Inducer: 0.08A . Gas pressure: 2.0 inches water column. Temperature rise: 53 . Supply: 123 . Return:70 . Flame:14.5uA. Suggestions: Need to add humidifier to maintenance plan at next renewal.


John M.

John M. Job Checkin

Ordered Drain Spud, Distribution tray, Center insert... Won't be delivered to shop till at least Wednesday... lke Tech to collect $182.85... ----------------------------------------------------------------------- Found water leaking from humidifier pad holder and drain spud..need to replaced pad as well...ordered call when comes in...collect remaining balance when installed... John’s notes: January 3, 2019 : Replaced distributor tray, pad frame, drain spud, and pad. Tested operation. Checked for leaks.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Blower: stg2: 4.6A . Inducer: 0.1/0.24A. Gas pressure: 2.0/3.5inches water column. Temperature rise: stg2: 60 . Supply: 128 . Return: 68 . Clean and check humidifier, replace pad, checked water flow and drain.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Blower: 2.2/2.8A . Inducer: 0.08//0.23A. check humidifier. checked water flow and drain. Calibrated humidistat.


John M.

John M. Job Checkin

Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked drain. Turned up humidistat. Blower: 2.2/5.3A . Inducer: 0.70/0.73A . Adjust Gas pressure:1.9 inches water column. Temperature rise: 53/59. Supply: 117/123. Return: 64. Suggestions: Replace thermostat batteries.


John M.

John M. Job Checkin

Cleaned and checked gas boiler. Checked voltage & amp draw of pump. Inspected heat exchanger & flue venting. cleaned burners & pilot assembly. Check compression tank pressure: 12. Tested water feed regulator. OK. Regulator setting: eight psi. Pressure gauge reads six PSI higher than actual. Checked vent. Oil pump motor. Set primary air. Supply: 137. Return: 105. Pressure: 22-6= 18.


John M.

John M. Job Checkin

Cleaned & checked 2 gas furnaces. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Replaced air filter. First floor system: customer complaint of noise when furnace turns on and when it turns off. I found no unusual noises at this time. Blower: 5.7A . Inducer: 1.25A . Gas pressure: 3.4inches water column. Temperature rise: 53 . Supply: 127 . Return: 74 . Second floor system: Blower:3.8A . Inducer: 1.2A . Gas pressure: 3.4inches water column. Temperature rise: 53 . Supply: 125. Return: 72 .


John M.

John M. Job Checkin

Customer replaced part that we delivered. Tested heat cycle. I collected payment.


John M.

John M. Job Checkin

Maintenance completed about two weeks ago. Found circuit boards showing pulse light: (normal no call for heat). Upon calling for heat board continued showing pulse indicator light! Picked up new board and replaced.


John M.

John M. Job Checkin

Found blower control board bad! Needs new board. Check temperature rise. 50. Suggestions: Need to check on cost and availability for repair.


John M.

John M. Job Checkin

Clean and check electric furnace. Tested heating elements. Tested sequencers. Checked voltage & amp draw of shaded pole blower. Vacuum filter. Total amps: 42.7. Voltage: 242. Check temperature rise. 38.


Jeff K.

Jeff K. Job Checkin

Fall maintenance today for the home furnace!


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced air filter. Blower: 5.0A. Inducer: 1.7A. Gas pressure: 3.5 inches water column. Temperature rise: 57.