1276 N. Warson
St. Louis, MO 63132
(314) 352-1111

Local Reviews

Rated 4.9 out of 5 stars based on 4214 customer reviews

The service was well done by an experienced service man who has been to my house several times.

Servive was well done.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

Service was quickly set up and Jake Kelly, the service tech was knowledgeable and professional. Said Nest thermostats routinely have problems when they are not connected to a common wire which he promptly hooked up and fixed the problem. It would seem this would be a standard item the installers would look for and correct to avoid post-install service calls.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Parkland - Glendale

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service Unhappy to spend so much on 3 year old unit

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service.

John's service is excellent.

  • Overall Experience
  • Quality
  • Price
  • Convenience

very professional service

I will be requesting Roger for all my heating/AC needs...very impressive

  • Overall Experience
  • Quality
  • Price
  • Convenience

Terrific service

Jeff Kelly is terrific. Professional and efficient and thorough. Thanks!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very knowledgible and helpful

  • Overall Experience
  • Quality
  • Price
  • Convenience

When he arrived he diagnosed the problem within minutes, very Satisfied

We won't have the A/C repaired totally until Roger can secure a part from Carrier, so far we are very pleased with the fine service we are receiving from CLASSIC AIR CARE! We appreciate the temporary fix that Roger performed!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Blower: 3.4A . Inducer: 1.03A . Gas pressure: 3.5 inches water column.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Humidity: 68%. Blower: 4.6A. Inducer: 1.62A . Gas pressure: 3.5 inches water column. Temperature rise: 52 . Supply: 130 . Return: 78 . Set supply air damper for winter. Clean and check humidifier, replace customer’s pad, checked water flow and drain. Replaced humidifier drain. Suggestions: Set fan to “auto” when in cooling mode for proper dehumidification.


John M.

John M. Job Checkin

I found dual run capacitor bad: open circuit. Also condenser coil very dirty. I replaced dual capacitor. Cleaned condenser coil. Rechecked Freon pressures and found a system low! I topped off to proper superheat level. Compressor:9.8A . Condenser fan: 0.8A . ambient: 78 . suction line: 62. metering device: piston . Suction pressure: 124(45). Return air wet bulb: 64.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Blower: 1.8A . Inducer:0.53A . Replaced air filter.


Jeff K.

Jeff K. Job Checkin

Mid season check up for the HVAC system! Good to go


John M.

John M. Job Checkin

Pumped down system. Removed closet doors. Removed and replaced evaporator coil of air handler. Pressurized to test connections for leaks. Evacuate low side. Topped off Freon level. Repaired closet door track and reinstall doors. liquid line: 86. suction line: 52 . metering device: TXV . Suction pressure: 138(40). head pressure: 282(92). Clean and check electric furnace. Tested heating elements. 58A. 209V. Tested sequencers. Checked voltage & amp draw of blower: 1560cfm. Replaced air filter. Clean and check humidifier, replace pad, checked water flow and drain. Set humidistat and dampers. Customer had to leave. Balance due for humidifier service and air filter.


Roger H.

Roger H. Job Checkin

Serviced furnace and air conditioner


Roger H.

Roger H. Job Checkin

Serviced air conditioners and replaced flue pipe


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Checked filter: very dirty. Also, filter not pushed all the way back to cover opening. Test capacitor. Customer plans to replace air filter. Blower: 2.6A . Inducer: 1.45A . Gas pressure: adj. 3.5 inches water column. Recommend humidifier maintenance. Humidifier drain is old and restricted. Cleaned and checked air conditioner. Checked drain: Old and restricted small tubing. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Compressor: 5.6A . Condenser fan: 0.62A . ambient: 69 . liquid line: 81 . suction line: 53 . metering device: TXV . Suction pressure: 118-121(40) . head pressure: 246(83). Sub cooling low: two. Manufacturers recommended specs: 10 sub degrees cooling. Work suggested: Replace air filter every month or two. Humidifier maintenance with water pan


John M.

John M. Job Checkin

Pumped down system. Removed and replaced evaporator coil. Pressurize and leak check connections. Evacuate low side and topped off Freon level. Compressor:9.3A . Condenser fan: 0.84A. ambient: 83. liquid line: 90 . suction line: 54 metering device: TXV . Suction pressure:119(40) . head pressure: 318(99). Return air: 69.


Roger H.

Roger H. Job Checkin

Serviced boiler


Jeff K.

Jeff K. Job Checkin

Cleared drain and cleared fitting—sign up for maintenance plan!


John M.

John M. Job Checkin

Second floor system: 1343: I found blower run capacitor extremely weak, causing motor to overheat and system to ice up. I replaced blower capacitor and tested cooling operation. Found dual run capacitor in condensing unit 22% oversized. Replaced with proper size capacitors. First floor system:3470: has bad compressor. Shorted to ground. Kitchen system: missing air filter. I installed air filter and set blower speed. Work suggested: Project manager is scheduled to price new air conditioner for first floor system. Recommend maintenance plan for three systems: $447


John M.

John M. Job Checkin

Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Replaced air filter. Compressor: 14.6A. Condenser fan: . Blower: 7.8A . ambient: 75 . liquid line: 79 . suction line: 53 . metering device: TXV . Return air: 76 . supply air: 53 . wet bulb: 62 .


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Blower: 3.1/ A . Inducer: .30/ . Gas pressure: 1.8/3.5 inches water column. Temperature rise: 44 . Supply:1: 119 . Return: 75 .