John is very professional and thorough! Hang on to this employee. These kind of employees are few and far between.
John M provides fantastic service. He is very knowledgeable and his attention to detail is great. I welcome him and ask for him every time.
John has always been professional and thorough. I always ask for him.
What I appreciate best about Classic Air Care is the customer service and clear communications. From the office staff to the technicians, we have never been disappointed and also learn a great deal about our HVAC maintainance.
Came on time. Did a thorough job and was very pleasant and professional
John Murphy is thorough and I have confidence in him. I always ask for him.
very informative, however, I am waiting for receipt of piece purchased for my A/C. please send
Classic Aire Care always does a good job and I especially like that they try hard to send out the same technician every time.
Ntg Previous tech was Corey. (part coming from Lennox in Georgia direct ship to us by Wednesday). Replaced dual pressure switches under parts only warranty. Tested operation. Checked temperature rise. 42. Inducer:0.1A. Blower: 1375cfm. Supply: 114. Return: 72.
Cleaned & checked 2 gas furnaces. Inspected heat exchangers & flue venting. cleaned burners & flame sensors. Checked voltage & amp draw of motors. Test capacitors. First floor system: Inducer: 0.08/0.25A. Blower: 2.3/4.0A. Checked manifold gas pressure: 1.9/3.6. Second floor system: Inducer: 0.07/0.24A. Blower: 2.0/3.0A. Checked manifold gas pressure. 1.9/3.6. Replaced air cleaner medias. Adjust blowers. Clean and check 2 humidifiers. replace pads. checked water flow and drains.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Set speeds. Checked filter. Customer serviced humidifier. Blower: 3.0/3.8A . Inducer: 0.09/0.24A . Gas pressure: 1.9/3.6inches water column. Temperature rise: 50/60 . Supply: 126/136 . Return: 76.
Cleaned & checked 2 gas furnaces. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced air filters. Second floor system: Blower: 2.0A . Inducer: 1.0A . Gas pressure: 3.5 inches water column. Temperature rise: 57. First floor system: Blower: 2.3A, 1063cfm. Inducer: p.51A, 3ph . Temperature rise: 59 . Supply: 129 . Return: 70 . Clean and check humidifier, replace pad, checked water flow and drain.
Cleaned & checked modulating condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Min/max: System: 0.95/5.0A . Inducer: 0.38/0.59A. Temperature rise: 60 . Blower: 1375cfm. Flame: 13uA. Setup for 3 stages.
Cleaned & checked condensing gas furnace. Checked drain. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Replaced air filter. Cal stat. Clean and check humidifier, replace pad, checked water flow and drain, Air: 900. Stages: 60,80,100%. Total amps: 2.3,3.3,4.8A.
Found smart valve system not sensing pilot flame. I checked gas supply pressure. I removed pilot assembly. . I found a tiny speck of something stuck in pilot orifice! I clean orifice, reassembled and tested. Working well every cycle.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Replaced air filter. Checked drain. Blower: m:1097, 2.3/5.5A . Inducer: 0.18/0.45A . Gas pressure: 1.8/3.8A inches water column. Temperature rise: 52. Clean and check humidifier, replace pad, checked water flow and drain.
Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. Complaint: exhaust smell in basement where PVC vent piping goes outside. I sealed with caulk pvc exits. Clean and check humidifier, replace pad, checked water flow and drain. I set up system for three stages instead of modulating for proper airflow through humidifier. Set humidifier to dewpoint Control. Checked temperature rise. 41. Rate: 60. Blower: 1008. Supply L131, R106. Suggestions: need to adjust perpetual maintenance plan to add humidifier.
Cleaned & checked 2 gas furnaces, 1 electric furnace, 1 electric package unit. Inspected heat exchangers & flue venting. cleaned burners & flame sensors. Checked voltage & amp draw of motors. Test capacitors. First floor system: Replaced thermostat batteries. Vacuum filter. Blower: 4.4/5.6A . Inducer: 0.31/0.60A. Temperature rise: 39/52 . Supply: 115/128 . Return: 76. Antique room: vacuum filter. Blower: 2.8A. Inducer: 0.95A. Gas pressure: 3.6 inches water column. Temperature rise: 66. Thermostat: 50. Supply: 128. Return: 61 . Second floor system: Replaced thermostat batteries. Vacuum filter. Tested heating elements. Tested sequencer. Checked voltage & amp draw of blower. Test capacitor. Package unit: Tested heating elements. System amp draw: 43.3A. Tested sequencers. Checked voltage & amp draw of blower. Test capacitor. Check temperature rise. 46. Return: 74. Supply: 120.
Clean and check electric furnace. Tested heating elements. 15kw. Tested sequencers. Checked voltage & amp draw of blower. Test capacitor. Total amps: 64. Voltage: 248. Tested thermostat batteries. Checked filter.
Cleaned & checked condensing gas furnace. Inspected heat exchanger with scope. Checked flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Checked drain. Replaced air cleaner media. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 2.6/6.8A . Inducer: 0.95/2.6A . Gas pressure: 1.7/3.6 inches water column. Temperature rise: 63/63 . Supply: 139/141 . Return: 76/78 .
Fall maintenance today for the furnace! Replaced filter and humidifier water panel. Good to go
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced air filter. Blower: 3.7A . Inducer: 1.42A . Gas pressure: 3.4 inches water column. Temperature rise: 51.
Fall maintenance today for the furnace!