Glad to get same day service. Technician friendly and knowledgeable. Think the $99.00 fee just to show up a bit steep.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for cottleville, mo

John M.

John M. Job Checkin

I found pressure relief valve stuck open. I removed and cleaned out relief valve. I reinstalled relief valve 4 feet higher using black iron pipe. I checked and set limit. Checked and set gas pressure. Bleed accessible baseboard radiators. Could not get to two radiators due to stuff in the way.


Jeff K.

Jeff K. Job Checkin

$69 Home Depot furnace tune up


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced air filter. Set thermostat for gas heat. Blower: 5.2A . Inducer: 1.15A . Gas pressure: 3.5 inches water column. Temperature rise: 44 . Supply: 117 . Return: 73 .


Corey S.

Corey S. Job Checkin

Repaired a/c system


Corey S.

Corey S. Job Checkin

Clean & check 3 a/c systems


Corey S.

Corey S. Job Checkin

Repaired some a/c things new install


John M.

John M. Job Checkin

Customer stated they found ice at outdoor unit. I turned on system and checked operation. Freon level is good. Customer had replaced very dirty air filter. Dirty filter had caused iced up system. New filter that is in system now is restricting airflow. TXV system is running at 19 degrees superheat. condenser coil: dirty. Compressor: 9.6A .Condenser fan: .85A. Blower: .ambient: 80 .liquid line: 95.suction line: 59 .metering device: TXV . Suction pressure: 118(40) .head pressure: 312(98.5). Return air: 75.5 .supply air: 54 .wet bulb: 63 .


Patrick O.

Patrick O. Job Checkin

Serviced air conditioning system


Jim T.

Jim T. Job Checkin

Furnace maintenance on Lennox system


Jim T.

Jim T. Job Checkin

Furnace maintenance on Lennox system


Jim T.

Jim T. Job Checkin

Furnace maintenance on trane system


John M.

John M. Job Checkin

Cleaned and checked air conditioner. Check drain. Check voltage and amp draw of motors. Test capacitors. Checked Freon level: Low. Temperature drop only 13.5. Humidity: 56%. Topped off to proper level per superheat chart. System may have a Freon leak. Found low latent heat to sensible heat removal ratio. Enthalpy Delta: 5.75. I adjusted blower speed for proper dehumidification and efficiency. Cleaned condenser coil. Compressor:14A .Condenser fan: 1.25A. Blower: 5.7 A .ambient: 89.liquid line: 96 .suction line: 60.metering device: piston . Suction pressure:136(48) . Return air: 78 .supply air: 57.5.wet bulb:66 . Enthalpy delta:7.3. 4 ton AC. 5 ton evaporator. Filter sucked out of place. Installed filter retainer.


Tom S.

Tom S. Job Checkin

Lennox air replaced dual capacitor


Jim T.

Jim T. Job Checkin

Ac maintenance on 2 newer Lennox systems