John Murphy has serviced our system twice and I have been very pleased with his work on both occasions. He arrives on time, is professional, careful, thorough and very courteous.
Installed Power humidifier. HCWP3-18. 2217K05360.
Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test inducer capacitor. Okay. Replaced air cleaner media. Check temperature rise. 49. Supply: 123. Return: 74. Inducer: .65A. Humidifier motor not working. Recommend new humidifier.
Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Replaced air filter. Compressor: 10A .Condenser fan: 2A . Blower: 1,600 .ambient: 67.liquid line: 72.5 .suction line: 50. metering device: TXV . Suction pressure: 112(37) .head pressure: 228(78) . Return air: 66.supply air:52.5 .wet bulb: 60