1276 N. Warson
St. Louis, MO 63132
(314) 352-1111

Local Reviews
for manchester, mo

Rated 4.9 out of 5 stars based on 7 customer reviews

Great service

Sean was very polite and friendly. He attended to his work and explained the problem with my furnace. I felt I could trust in his recommendation.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Top Shelf

Sean should be commended for his professionalism and overall customer service skills. He arrived on time, completed the service call in a timely manner and provided a complete overview of the service maintenance items that you completed.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service.

Jeff is a credit to your company.

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick resolution of problems with A/C

  • Overall Experience
  • Quality
  • Price
  • Convenience

All seems good

Great, as expected

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for manchester, mo

John M.

John M. Job Checkin

I found liquid line solenoid valve inside the condensing unit shorted, causing unit to run without a call for cooling. I wired unit to bypass solenoid valve. Valve was only used for efficiency improvement. I found system approximately 30% low on Freon. I topped off partially with 1 pound of R-22 Freon for temporary cooling. Suction: 74(44). Suction line: 68. Expect Freon will leak back out. Recommend replacing air conditioner. Repair cost may apply to new equipment. Project manager is scheduled for before 4 o’clock tomorrow. Need to call customer to confirm a timeframe.


John M.

John M. Job Checkin

Cleaned and checked 3 air conditioners. Checked drains. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon levels. Cleaned condenser coils. Checked filters. Bedroom system: Compressor: 11.5A .Condenser fan: 1.45A . Blower: 6.1A .ambient: 76.liquid line: 85. suction line: 40 .metering device: Piston. Return air: 72.supply air: 52.5 .wet bulb:62 . Living room system: Compressor: 11.6A .Condenser fan: 1.2A . Blower: 6.1A,m.ambient: 78 .liquid line: 98.suction line: 39 .metering device: piston . Return air: 71 .supply air: 51.5 .wet bulb: 61 . Rear system: was reconnected earlier today. I found system 75 to 80% low on Freon. If Freon was pumped down properly when unit was disconnected (By others last year) there should be close to a full charge and the air-conditioner. System may have a Freon leak. System uses the older type of Freon that is being phased out. needs R22 Freon charge: $456. Freon leak search: $189. Freon leak repair:


Tom S.

Tom S. Job Checkin

Goodman air conditioner


Tom S.

Tom S. Job Checkin

Maintenance on Lennox heat pump


Jeff K.

Jeff K. Job Checkin

AC maintenance! Replace filter and weak dual capacitor!


Tom S.

Tom S. Job Checkin

A/C start up on new Lennox install


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. I replaced air cleaner media. I tested zone system and found 1 zone damper not closing for zone two.


John M.

John M. Job Checkin

Customer complaint: gas bills were higher than last year. I explained that the air conditioner is 50% more efficient, not the furnace. I fine tuned furnace using combustion analyzer. Stage one: manifold: 2.6 inches. Oxygen: 7.4%. CO: 42 ppm. Stack: 349. Supply air: 123. Return air: 69. Temperature rise: 54. Inducer: .08 A. Blower: 4.2 A. Stage two: timing: 12 minutes. manifold: 4.0 inches. Oxygen: 7.7%. CO: 29. Stack: 421. Supply air: 128. Return air: 69. Temperature rise: 59. Inducer: 0.22 A. Blower: 5.2 A.


Sean K.

Sean K. Job Checkin

Clean and check, customer complained of noise, found blower motor bad and split in eyelet in heat exchanger

Clean and check, customer complained of noise, found blower motor bad and split in eyelet in heat exchanger

Sean K.

Sean K. Job Checkin

C cancelled


Dave G.

Dave G. Job Checkin

Scheduled maintenance on a Lennox furnace.


Dave G.

Dave G. Job Checkin

Scheduled maintenance on a Amanda furnace.


Sean K.

Sean K. Job Checkin

Clean and check


Patrick O.

Patrick O. Job Checkin

Cleaned dirty flame sensor


Sean K.

Sean K. Job Checkin

Clean and check