Found dual capacitor bad. Open circuit. Replaced dual capacitor and tested cooling operation. Compressor: 16.6A. Condenser fan:1.45A . ambient: 94 . liquid line: 98. suction line: 66. Suction Indoor temp: 85.
Customer had burst water pipe that froze above garage ceiling. I found heating only air handler above garage ceiling had burnt up circuit board. Also capacitor weak: 16% low. I removed burnt circuitboard and rewired furnace for standard sequence your operation. Installed new sequencer and replaced blower capacitor.
Found dual run capacitor or bad. Open circuit. Replaced dual capacitor and tested cooling operation. Compressor: 16.7A .Condenser fan: 1.4A .ambient: 84 .liquid line: 93 .suction line: 68 .metering device: TXV . Suction pressure: 139(48).