HVAC Service Checkup

John Murphy arrive for appointment at 8am. He asked questions about how furnace was keeping up with cold weather. John checked furnace and found wire that had vibrated loose. He repaired wire and improved efficiency of furnace. John checked heatpump and found no problems. I would refer John to anyone for HVAC service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Comprehensive service by a qualified professional!

Jeff Kelly is first rate! Two thumbs up!

  • Overall Experience
  • Quality
  • Price
  • Convenience

winter service of furnace

service was prompt and courteous

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Disgruntled

Tom seemed very disgruntled about providing service at my home. He didn't know much about the Nest Thermostat I had purchased or about my previous thermostat. He even asked me why I purchased the Nest in a condescending tone. This was not his business.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good job. Very professional and polite

  • Overall Experience
  • Quality
  • Price
  • Convenience

On time, clear, helpful

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt and courtious service

Sean arrived on time and completed the service on schedule. He provided information on surge protection for me to consider.

  • Overall Experience
  • Quality
  • Price
  • Convenience

A/C Maintenance service

Patrick was on time, did a great job and was very friendly

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for wildwood, mo

John M.

John M. Job Checkin

Cleaned & checked 2 gas furnaces. Inspected heat exchanger & flue venting. cleaned burners & flame sensors. Checked voltage & amp draw of motors. Test capacitors. Checked filters. East system: Blower: 5.8A . Inducer: 1.62 . Gas pressure: 3.4 inches water column. Temperature rise: 59 . Supply: 130 . Return: 71. West system: Found run capacitor weak: 11.5%low. Customer declined repair at this time. Blower: 5.9A . Inducer: 1.52A . Gas pressure: 3.4 inches water column. Temperature rise: 56 . Supply: 127. Return: 71 .


John M.

John M. Job Checkin

Cleaned & checked 2 condensing gas furnaces. Inspected heat exchangers & flue venting. cleaned burners & flame sensors. Checked voltage & amp draw of motors. Test capacitors. Checked filters. Checked zoning system. Main system: Clean and check humidifier, replace pad, checked fan. checked water flow and drain. Blower: 7.1A. Inducer: 1.9A . Gas pressure: 3.6 inches water column. Temperature rise: 60 . Supply:133 . Return: 73 . Second floor system: Blower: 3.4A . Inducer: 1.9A. Gas pressure: 3.4 inches water column. Temperature rise: 61 . Supply: 130 . Return: 69 .


John M.

John M. Job Checkin

Clean and check electric furnace and heat pump. Tested heating elements. Tested sequencers. Checked temperature rise. 15kw. System amps: 65.5. HP temperature rise: 25. Compressor: 13.3. Condenser fan: 1.23A Blower: 1600. ambient: 51 . liquid line: 94 . suction line: . metering device: TXV . Return air: 70. supply air: 95. Tested defrost cycle.


John M.

John M. Job Checkin

First floor system: I found sequencer 1 stuck on and sequencer 2 stuck open. Replaced sequencers. Tested all elements. I replaced defrost control board for heat pump. Tested operation. Tested defrost cycle. Ambient: 47. Suction: 60. head pressure: 215. Checked temperature rise. 13. Found system is low on type 410A Freon!! Leak searched and found Freon leak at indoor coil! Large leak in middle of left side of coil. Suggestions: need to check on cost and availability of replacement coil for first floor air handler. Heat pump system is about 11 years old. Recommend replacing system.


John M.

John M. Job Checkin

Cleaned & checked 3 gas furnaces. Inspected heat exchangers & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitors. Replaced air filters. Second floor system: Blower: 3.4A . Inducer: 1.75A . Gas pressure: 3.4 inches water column. Temperature rise: 61 . Supply: 131 . Return: 70 . Main/basement system: zone one, damper A does not close. (Stuck open). System is working with no overheating area problems. Blower: 7.2A . Inducer: 1.75A . Gas pressure: 3.4 inches water column. Temperature rise: 65 . Supply:136 . Return: 71 . Master bedroom system: excessive supply duct pressure (-.35 inches) causing whistling noise at humidifier. Customer opened supply vents to reduce pressure. Whistling noise stopped. Blower: . Inducer: . Gas pressure: 3.4 inches water column. Temperature rise: 68 . Supply: 143 . Return: 75 . Suggestions: if damper #A replacement is needed, return air Trunkline will have to be dr


John M.

John M. Job Checkin

Cleaned & checked w gas furnaces. Inspected heat exchangers & flue venting. cleaned burners & flame sensors. Tested current. 16uA. Checked voltage & amp draw of motors. Test capacitors. Checked filters. Checked for stored faults. OK. First floor system: Blower: 2.1/3.5A Inducer: 0.09/0.23A . Gas pressure: 1.9/3.6 inches water column. Temperature rise: 44/48. Second floor system: Blower: 1.8/3.2A . Inducer: 0.08/024A. Temperature rise: 48/52 .


John M.

John M. Job Checkin

I turned off water to the house and installed new supply valve for humidifier to Cold water line. Turn water to house back on. Replaced solenoid valves under parts warranty for both humidifiers. Serviced humidifiers for winter and replaced water panels. Replaced drain tubing for both humidifiers. Installed 10VA transformers for both systems to enable humidifiers to run during blower operation. Tested water flow and a drain.


John M.

John M. Job Checkin

Found transformer primary winding open. Replaced transformer. Found old style humidifier wired for new style. Cut out transformer board. Connected humidifier fan to accessory terminal. Connected humidifier solenoid valve to humidifier terminal.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Check humidifier, checked water flow and drain. Solenoid valve has blockage. Replaced solenoid valve. Customer replaces pads. Blower: 3.8/4.9A . Inducer: 0.11/0.23A. Gas pressure: 1.7/3.5inches water column. Temperature rise: H: 51 . Supply: 133 . Return: 82 .


John M.

John M. Job Checkin

Customer stated humidifier would go on and off again in about 1 minute intervals. I turned on humidifier at thermostat. Tested solenoid current: 0.22A. I checked humidifier operation and found working okay at this time. But, I found i-comfort thermostat humidity reading (<15%) was off by 40 percentage points! I replaced under parts warranty. Set parameters. Set wi-fi connection. Thermostat now reading 55% humidity.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor.


John M.

John M. Job Checkin

I found no voltage coming out to disconnect box. Found circuit breaker tripped! Reset breaker and tested cooling operation. Ambient: 85. Liquid line: 89. Suction line: 62. Ramping stage: 100%. Compressor: 9.6/9.6/9.6 A, 230V. Indoor wetbulb: 67. Condenser fan: .95 A. Test a breaker and found bad internal connection causing breaker to overheat. I replaced circuit breaker.


John M.

John M. Job Checkin

Cleaned and checked 2 air conditioners. Checked drains. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon levels. Cleaned condenser coils. Checked filters. First floor system: Found blower run capacitor weak: 18%low. Replaced capacitor and tested amp draw. Compressor:19.5A . Condenser fan: 0.74A . Blower: . ambient:83 . liquid line: 98. suction line: 40 . metering device: piston. Return air: 73.5 . supply air: 53 . wet bulb: 61. Second floor system: Found poor temperature drop. 17. CC: 45. Condenser coil very dirty. Cleaned condenser coil. Recheck Freon and temperature drop. Rem: 1. Compressor: was5.4A. Condenser fan: 0.79A . Blower: 5.4A . ambient: 85 . liquid line: 98. suction line:47-55 . metering device: piston . Suction pressure: 130(45) . head pressure:318-327 . Return air: 75.5 . supply air: 55.5. wet bulb: 63 .


John M.

John M. Job Checkin

Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Replaced air filter. Compressor: 9.7A. Condenser fan:1.17A . Blower: 1600 . ambient: 65. liquid line: 71 . suction line: 51 . metering device: TXV . Suction pressure:113(37) . head pressure: 214(74) . Return air: 71. wet bulb:58 .


Jeff K.

Jeff K. Job Checkin

Replaced warranty evap coil and install hard start kits in both ACs