5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for braselton, ga

Rated 4.9 out of 5 stars based on 36 customer reviews

Great Presentation. We will buy from you after we resolve a Roof Replacement Situation.

Great !!! Wonderful !!!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great

Very well. He was knowledgeable and answered all my questions. Good Technician. An asset to your Company

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great

Couldn't have been better

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Customer Service

Ta was super friendly and very knowledgeable. He explained every single thing he was doing.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

HVAC repair

Reece did a great job. Very professional. Very friendly.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

HVAC repair

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Awesome Customer Service

Outstanding

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for braselton, ga

Garrett G.

Garrett G. Job Checkin

Free consultation


Jon F.

Jon F. Job Checkin

Completed 2 system maintenance found both systems clean on inside with good electrical components. All safety switches working. Changed filters. Cleared drain lines. Outdoor units have good pressures. Cleaned off both condensers. Systems running with no compressor saver or surge protector. Needs both. Installed compressor saver to both. Systems cooling at this time.


Jordan R.

Jordan R. Job Checkin

1 system cool pm. Cleaned outdoor coil and checked all components. Capacitor good reading along with hard start compressor saver. Outdoor fan rusted from over heating. Compressor sounds rough on startup. Discovered system low on charge again. System requires R22 which manufacturing has been banned as of January 1 this year. System 14 years old. Recommend replacement.


Garrett G.

Garrett G. Job Checkin

Free consultation


Jon F.

Jon F. Job Checkin

Completed one system maintenance found blower wheel clean. Cleared drain line. System has no back up water safety. Needs inline float switch. Installed inline float swit h. UV light is good left new filter. Outdoor has all good electrical. Good pressures. System is cooling at this time.


Reece W.

Reece W. Job Checkin

2 system ac tune up complete. Left behind replacement filters. Cleared drain lines. Tested mechanical and electrical components. Found downstairs system with very rusty, corroded evaporator coil, likely to leak. Found upstairs blower capacitor to be weak (10 uf), recommend repair. Found downstairs blower capacitor to be weak (5 uf). Found downstairs dual capacitor to be weak (30/5 uf). Due to age and condition of downstairs system, recommend upgrading system to a more reliable, more efficient system. Downstairs system runs on r22 which is a refrigerant that has been phased out by the epa. Systems are cooling at this time.


Jon F.

Jon F. Job Checkin

Complete 1 system A/C repair and preventative maintenance check. found the system running well with no issues at this time. Filter is clean. Cleared drain line. Checked all safety switches. Blower wheel is clean and electrical components inside and out are running good. Pressures are good. System running with no compressor saver or surge protector that can lengthen the lifespan of system and reduce power bills. Also system is running with just standard one in filter. Needs electrostatic filter to better clean the air and keep system and house cleaner longer. Also needs UV inhibitor to get rid of current growth inside system and prevent new growth from happening to keep residents healthy.


Jon F.

Jon F. Job Checkin

Complete 3 system a/c repair and preventative maintenance check. found all systems outside working properly. All electrical components are good. Pressures are good. Main floor and basement dehumidifier working well. Filters clean. Furnaces are good. Blower wheels are ok. Capacitors are good. Filters are clean. Drain lines are cleared. The upstairs furnace is good. The blower is clean and the capacitor is good. Zone board working properly.


Reece W.

Reece W. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Changed filters. Cleared drain lines. Dusted out electrical cabinets. Tested mechanical and electrical components. Found the main level system with damaged electrical disconnect box at the air handler, plastic is melted and the plug will not come undone. Recommend repair. Found weak dual capacitor in main level heat pump, recommend repair. Replaced damaged disconnect box, installed surge protection on all hvac equipment, and replaced the main level capacitor. Systems are cooling at this time.


Reece W.

Reece W. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Changed filters. Cleared drain lines. Dusted out electrical cabinets. Replaced upstairs uv bulb. Tested mechanical and electrical components. Found upstairs blower capacitor to be weak (12.5 uf) recommend a repair. Found upstairs ductwork on supply plenum not properly sealed with some air leakage. Recommend properly sealing ductwork for better efficiency and no air leakage. Neither system has a hard start kit, recommend adding on to reduce load on compressor so it starts smoother, runs smoother and therefore lasts longer. Neither system has surge protection, recommend adding on to protect equipment from power surges. Sealed duct connections at supply plenum of upstairs system, replaced upstairs blower capacitor and installed surge protection for both condensers. Systems are cooling at this time.


Casey M.

Casey M. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Reece W.

Reece W. Job Checkin

Complete 2 system a/c repair and preventative maintenance check. Changed filters. Fixed suction line insulation. Tested mechanical and electrical components. Found upstairs dual capacitor to be weak, recommend a repair. Found upstairs blower capacitor to be weak, recommend a repair. Systems are heating at this time.


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Steve I.

Steve I. Job Checkin

Complete 3 system furnace repair and preventative maintenance check. Replaced basement filter. Cleaned Trane clean effects filters. Recommend adding Air Purifiers to Systems. Recommend adding an inline water safety switch in the summer for the upstairs furnace. Systems are heating good at this time and at safe levels.


Reece W.

Reece W. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Found loose connection at air handler disconnect box. Pushed in plug and system is heating normal at this time.