5322 Palmero Ct
Buford, GA 30518
770-203-1600

Local Reviews
for dacula, ga

Rated 4.9 out of 5 stars based on 9 customer reviews

Awesome service

Dylan and Eric were such hard workers. It was very cold the day of the installation, but they didn’t let that slow them down. I am very happy with the install.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Timely, professional, friendly

Professional & efficient. Got right to us

  • Overall Experience
  • Quality
  • Price
  • Convenience

Winter maintenance visit. Loved Paul's professionalism.

Paul was professional, knowledgeable, and I felt a sense of trust with him. I truly appreciated the Saturday morning maintenance visit since there was not an available date before January.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Previentative Maintenance

Team does a great job of communicating with customer before, during and after visit. All work as agreed without error.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Winterize furnace for winter

Service Technician was on time and did his work in a timely manner. No major problems but explained there may be issues in the future which relates to wear and tear.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome Tech

Brian Malone is the best tech we've had visit our home.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Brian is such a great Tech

Brian is the best who has ever come to our home. Please send him for every appointment.

  • Overall Experience
  • Quality
  • Price
  • Convenience

just had checkup for Winter heating and cleaning

today had my winter servicing, they came in serviced showed us what looked to need a look at later had systems up and running, nice guy, very pleasant and knowledgeable. Glad I switched to Comfort control in july and bought their service plan.

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dacula, ga

Reece W.

Reece W. Job Checkin

Found system low on charge due to leak at evaporater coil service port, leaky schrader valve. Replaced all schrader valves, replaced all brass caps, tightened connections, added thread sealant to evaporater coil service cap and condenser service ports. Pressure and leak tested system. Pulled vacuum to 500 microns. Recharged system and it is cooling at this time. Need to come back during summer with hotter temperatures to retest pressures. Left customer with replacement filter. All under warranty.


Vu T.

Vu T. Job Checkin

Complete 2 heating tune up. Change filter, check safety and operation. Find both system have weak and worn blower SMC, no water protection. Both system coil rusted. Both system operating at this time. Both system 16 year old, suggest to upgrade system due to age and ware on parts.


Reece W.

Reece W. Job Checkin

1 furnace tune up complete. Found high limit switch tripped due to clogged filter. Changed filter and system is heating. Tested combustion and found safe carbon monoxide levels and good oxygen levels. Tested mechanical and electrical components and found flame safety sending weak micro amps to control board, recommend replacing flame safety. Recommend adding secondary water safety to help prevent future water damage. System is heating at this time. Customer upgraded tune up to maintenance plan.


Vu T.

Vu T. Job Checkin

Replace blower smc, flame safety and also replace burnt inducer combustion motor. Test and system operating at this time. System still have worn part will need to keep check. System operating at this time.


Vu T.

Vu T. Job Checkin

No heat. Check and find heating system lock out due to overheating. Test and find blower motor capacitor bad, find flame safety weak and worn, ignition white and cracking, and blower wheel not balance and dirty. Find furnace control also not operating properly. Due to system age and poor conditions of heating system suggest to customer to upgrade heating system. Repalce filter. Give customer estimate and customer will call cci back . System off at this time


Reece W.

Reece W. Job Checkin

1 furnace on check complete. Changed filters. Tested mechanical and electrical components, all in good shape. Recommend apco air purifier to help keep evaporater coil clean and to kill bacteria, germs, viruses and vocs for improved air quality. Recommend surge protection to protect furnace from power surges. System is heating normal at this time.


Tom K.

Tom K. Job Checkin

Provided estimate for new Heating and Air Conditioning System Installation


Vu T.

Vu T. Job Checkin

Complete heating preventative maintenance check. Find heating 3-year-old Lennox heating system operating normally at this time.


Reece W.

Reece W. Job Checkin

2 furnace tune up complete. Found main level furnace with weak blower motor controller. Recommend repair. Main level flame safety and upstairs is putting out weak microamp readings, it could fail at any time. Recommend repair. Tested combustion on both systems and found safe co levels. Systems are heating at this time.


Reece W.

Reece W. Job Checkin

2 furnace tune up complete. Found main level furnace with weak blower motor controller. Recommend repair. Main level flame safety and upstairs is putting out weak microamp readings, it could fail at any time. Recommend repair. Tested combustion on both systems and found safe co levels. Systems are heating at this time.


Reece W.

Reece W. Job Checkin

2 furnace tune up complete. Found main level furnace with weak blower motor controller. Recommend repair. Main level flame safety and upstairs is putting out weak microamp readings, it could fail at any time. Recommend repair. Tested combustion on both systems and found safe co levels. Systems are heating at this time.


Reece W.

Reece W. Job Checkin

2 furnace tune up complete. Changed filters. Tested mechanical and electrical components, all in good shape. Systems are heating normal at this time. Customer upgraded tune up to maintenance plan.


Vu T.

Vu T. Job Checkin

Complete 2 heating tune-up. Find upstairs heating operating with worn ignition, weak flame safety, and weak blower smc. Find main system operating with badly worn flame safety and blower smc reading 4.5/10uf rated. Need to replace both parts to prevent failure. System operating but not reliable. Change both filter and complete check. Find open floor plan house in living room causing upstairs to be hotter. The downstairs thermostat should be in the master bedroom to have better control of that room's comfort level.


Dylan W.

Dylan W. Job Checkin

Heating and Air Conditioning Installation - Upstairs System (2.5Ton Full System) *Standard Airflow Capacity * Standard efficiency * Powder paint finish with salt-spray approval * Copeland scroll compressor * High-density compressor sound blanket * Copeland ComfortAlert diagnostics * Single panel access to controls * 10 year compressor warranty * 10 year parts warranty *10 Year Labor warranty * Standard 80% level of heating efficiency * Single-stage gas valve * Single-speed blower motor * Lifetime heat exchanger warranty -1in filter rack(16x25x1) -10in or 8in return in Master Bedroom above the thermostat -6in supply in daughters bedroom -Downstairs System (2.5 Ton Full System) Standard airflow capacity * Standard efficiency * Powder paint finish with salt-spray approval * Copeland scroll compressor * High-density compressor sound blanket * Copeland ComfortAlert diagnostics * 10 year compressor warranty


Reece W.

Reece W. Job Checkin

1 furnace maintenance check complete. Changed filter. Found weak flame safety, recommend repair. Replaced flame safety. System operating normally at this time. The gas line is not up to code. The blower wheel is dirty, recommend cleaning.