5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for dacula, ga

Rated 4.9 out of 5 stars based on 69 customer reviews

Great service

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Very professional and personable. Always a pleasure to see Reece

I completely trust Reece. He is an really sharp individual. I appreciate his guidance.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Best service ever!

I've been using Comfort Control for a couple years. Their service is absolutely second to none! I'll never use anyone else!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Fast courteous and competent!

Comfort Control Heating and Air has a well trained team from customer focus to technical competence. Highly recommend them and Ta Kim in particular.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great job

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service

Jordan came out to trouble shoot our recently purchased unit as it wasn't heating the main level of the house. Found the issue and quickly fixed the problem.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service

Very professional and knowledgeable.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service

Ya was very friendly and knowledgeable. Answered all of our questions.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for dacula, ga

Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Ta K.

Ta K. Job Checkin

Complete 2 system furnace repair and preventative maintenance check. Upstair system fan runs constantly and set for auto. Disconnect the variable speed plug from the control board and the fan still runs. Found variable speed motor and module stuck close. When switch to the fan on the variable speed board sends a signal to the module to run at a lower cfm. The system is old and needs to be replaced.


Ta K.

Ta K. Job Checkin

Complete 3 system furnace repair and preventative maintenance check. Owner replaces their own filters, checked electrical and safety switches all ok at this time. Did a combustion test and all within range. Found mold inside air handler, owner will clean it himself. Overall 3 system heating normal


Reece W.

Reece W. Job Checkin

Complete 3 system furnace repair and preventative maintenance check. Changed filters. Tested mechanical and electrical components. Systems are heating at this time.


Ta K.

Ta K. Job Checkin

Complete 2 system furnace repair and preventative maintenance check. Replaced dirty filters, checked electrical and safety switches all ok at this time. Replaced bad flame sensor for downstair system and Upstair flames sensor is weak. The owner wants to wait for the upstair flame sensor. Replaced Downstair flame sensor and downstair is heating normal. Did a combustion test and furnace is safe to operate at this time. Both furnaces heating normal


Jon F.

Jon F. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. found run capacitor for blower running weak and needs to be replaced. The blower wheel is clean and the filter will need to be changed in spring. Ignitor and flame sensor clean. And combustion is good. System running with no secondary water safety device and needs an inline float switch on main drain line. System would benefit from having inhibitor which will kill bacteria allergens and odors in house improve wellness for residents. Home will also benefit from having an attic tent installed which will prevent heat from escaping into attic and decrease run time for the furnace which overall will increase lifespan of system and decrease bills.


Casey M.

Casey M. Job Checkin

Complete 3 system furnace repair and preventative maintenance check. Changed filters. Ran static pressure tests on all systems, pressures did not exceed system max ratings. Performed combustion analysis on both furnaces: the basement furnace CO levels are low and O2 levels are within range; I found the attic system to be slightly under fire (CO levels low and O2 levels are high). Tested all electrical and mechanical components, and all readings are nominal.


Ta K.

Ta K. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Ta K.

Ta K. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. The system threw code 6 for pressure switch. Reset and the system came on then shut off and back on. Bypass the pressure switch and the system runs normally. Lennox had one in stock, drove to Lennox to pick up the part. Installed new part under warranty, tested and working normally. Needs surge protection.


Vu T.

Vu T. Job Checkin

Complete 3 system furnace repair and preventative maintenance check. Check and find upstairs heating furnace 21-year-old operating but intermittent miss fire and ignition cannot start up the furnace. Find flame sensor weak, worn pressure switch and molded air distribution system. Need to repair the upstairs system and remove the old air distribution box. System need air purifier system to remove and help kill Molds. Find main furnace 2-year-old operating normal within manufacturer spec. Find basement heatpump/Airhandler operating with restrictions liquid line, need to replace king valve for proper flow. System freezing up Heatpump unit. The system also 19-year-old with phaseout equipment. Suggest to upgrade the system and not do the repair.


Vu T.

Vu T. Job Checkin

complete 2 system furnace repair and preventative maintenance check. 5-year-old Lennox heating furnace. Find both systems operating within manufacturer spec but efficiency. Both furnace under fire and high O2 level. Change both filters, check safety and operations. Adjust master bathroom damper to reduce airflow. Suggest an electric static filter and suggest calibration service.


Ta K.

Ta K. Job Checkin

Complete 2 system furnace repair and preventative maintenance check. Checked electrical and safety switches all ok at this time. Did a combustion test and found both systems with high oxygen content. Both furnaces are not burning efficiently. Found main floor system with worn ignition and weak flame sensor. Overall both system heating normal


Vu T.

Vu T. Job Checkin

Complete 2 system furnace repair and preventative maintenance check. Change both filter customers provided. Check safety and operations. Find both heating systems operating within manufacturer spec. No concern at this time.


Reece W.

Reece W. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Changed filter. Added drain pan treatment into the system. Cleared drain line. Dusted out furnace cabinet. Tested mechanical and electrical components, all in good shape. The system is heating normal at this time.


Steve I.

Steve I. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Replaced filter. The system is old and the condition is bad. The system should be upgraded. Recommend having a Comfort Advisor come out and give options.