5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for flowery branch, ga

Rated 4.8 out of 5 stars based on 193 customer reviews

Great, as usual!!

Jordan knows his stuff! He's friendly and professional. He does an in depth examination, and explains his findings.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Prompt and very informative

Very good at explaining, very respectful

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great

Wish it didn’t happen but now it’s fixed

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service

Great job

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service

Vu was great and gave a thorough explanation of everything he was doing and included me in his observations. An excellent communicator!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service

John was very friendly and professional.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Casey is great

Casey is great

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Friendly service

The technician was friendly and well informed and very thorough.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Thermostat issues

5 star all the way around

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Fall Furnace Checkup

Very professional, friendly and efficient. What more could you ask for?

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Job Locations
for flowery branch, ga

Reece W.

Reece W. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Reece W.

Reece W. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Found system fully operational upon arrival, however, the capacitor is weak. Recommend repair and hard start kit. Heat pump may have had trouble keeping up due to cold weather. Replaced capacitor and installed hard start kit. System is heating at this time. Hard start kit and capacitor have a 2 year warranty.


Jordan R.

Jordan R. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Homeowner said the system was shutting off on outdoor sensor fault. When I arrived there was No-fault lockout but the thermostat was securely on the base. Checked system operation. All airflow settings, wiring, pressures, and components normal. Ran system continuously for 30 minutes while observing components. System operation normally.


Reece W.

Reece W. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Found system shut off on high limit due to clogged filter. Changed filter and system is heating at this time. Found failed condensate pump and very dirty Beckett tubing. Recommend repair and new tubing. customer declined repair for now. Signed customer up for one system maintenance plan and will return to do maintenance visits later.


Jordan R.

Jordan R. Job Checkin

Complete 2 system furnace repair and preventative maintenance check. Changed the blower motor in the upstairs system. System operation normal at this time.


Steve I.

Steve I. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Replaced filter. The correct filter size is 16x25x4.5. The system is heating well at this time.


Steve I.

Steve I. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Reece W.

Reece W. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Fan would not turn off after the customer changed the thermostat. The screw had damaged thermostat wire. Added electrical tape to wires to prevent them from shorting out. Tested mechanical and electrical components. Found weak flame safety sensor. Recommend repair. System has no overflow protection switch, recommend adding on to protect furnace from potential water damage and to serve as a backup to primary water safety. Furnace has no surge protection, recommend adding on to protect furnace from power surges. System is heating at this time.


Reece W.

Reece W. Job Checkin

Complete 2 system furnace repair and preventative maintenance check. Changed filters. Tested components. Found upstairs blower capacitor to be bad, changed it out under warranty. Found ductwork on the upstairs system to be undersized causing strain on the blower motor. 8" return and 6" supply need to be added to the system for proper airflow. Found no issues with the main level system. Neither system has surge protection, both systems need surge protection to protect equipment from power surges. Systems are heating at this time.


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Vu T.

Vu T. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Check and find the compressor for heatpump overheated. Find a weak capacitor and fan motor leaking oil. Find Airhandler very dirty and molded. Find burnt wires and burnt contactor. Find the blower motor module burnt. Need to replace Trane heat-strip kit and contactor with line voltage re-build. System 16 year and phase out equipment. Need to replace and not repair.


Ta K.

Ta K. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Replaced filter, checked electrical and safety switches all ok at this time. Found blower motor draws high amps and dirty blower wheel. Found rusty evaporator coil and system is 17 years old. Found compressor draws 17 amps and rated for 21.2. The compressor is overheating. The system is old and needs to be replaced, the system is heating at this time


Vu T.

Vu T. Job Checkin

Complete 1 system furnace repair and preventative maintenance check. Check and find Trane furnace lock out on safety due to pressure stuck open. Reset system and system operating but pressure switch worn and not closing properly. Find ignition is worn and flame sensor weak reading below 1.3. The system furnace control board also not resetting properly. Furnace blower assembly very dirty. System gas line not up to code and flue pipe, not code. Due to system age and wear on equipment. Need to replace and not repair. Customers need an estimate to upgrade the system and move the system into the attic.


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Jordan R.

Jordan R. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.