5322 Palmero Ct
Buford, GA 30518
770-203-1600

Local Reviews
for flowery branch, ga

Rated 4.9 out of 5 stars based on 15 customer reviews

Excellent service!

Reece was very courteous and professional!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Comfort Control Competence

Your MAN was courteous, fast, and efficient. We really liked him. Looking forward to our duct cleaning.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very efficient service

I've always had professional service and have been happy with the furnace and air-conditioner.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt and efficient

Couldn't expect better.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Solid service

Tech did the work we asked for promptly and told us what he was doing each step of the way.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Solid service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very nice young man

Paul showed up right on time, very polite,knew just what to do.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Technician

Reece was prompt, courteous, professional, and explained what he accomplished during tge service call.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Another successful service call

As always, great service and knowledgeable service tech (Reece).

  • Overall Experience
  • Quality
  • Price
  • Convenience

Above and beyond any other prior service call experience.

Ask for technician Ta Kim.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for flowery branch, ga

Reece W.

Reece W. Job Checkin

2 heating system pm check complete. Changed filters. Tested mechanical and electrical components, all in good shape. Recommend apco air purifiers to keep evaporater coils clean and to kill mold, bacteria, germs and viruses for improved air quality. Recommend surge protection to protect units from power surges. Systems heating normal at this time.


Phillip S.

Phillip S. Job Checkin

Completed maintenance on newer furnace. Found loose connection on zone damper for upstairs, fixed issue and tested system. Found piece of paper stuck in blower wheel removed paper and everything operating normal at this time.


seth@comfortcontrolinc.com

seth@comfortcontrolinc.com Job Checkin

Found bad gas valve. Older Armstrong furnace. Smart valve gas manifold needs replacing


Phillip S.

Phillip S. Job Checkin

Completed maintnenace on 2 systems. Changed filters, checked all electrical, mechanical and safety's. recommend blower wheel cleaning and air handler cleaning on basement system due to dust build up. Both units are operating normal at this time.


Reece W.

Reece W. Job Checkin

1 furnace pm check complete. Changed filter. Tested mechanical and electrical components, all in good shape. Found co level at 85 ppm, recommend recalibration to lower co levels. Recommend low level co detector. System is heating normal at this time. Recalibrated system for lower co levels.


Phillip S.

Phillip S. Job Checkin

Found unit not safe due to heat exchanger issue. Customer wants to replace 2 ton gas package unit. Collected money through green sky financing.


seth@comfortcontrolinc.com

seth@comfortcontrolinc.com Job Checkin

Performed 1 system heating maintenance. Very bad black mold problem. Airhandler needs u/v lighting system to kill mold and bacteria. Filter is a ultravation 20x25x5 and needs to be replaced in the spring. Flushed drain line. System is operating properly at this time.


dylanwages@gmail.com

dylanwages@gmail.com Job Checkin

The bottom high limit switch directly beside the burners was set off. I reset the high limit and checked a variety of sub systems to see what may have triggered the set off. All of the system's components are performing within normal range with no obvious sign of the cause.


Phillip S.

Phillip S. Job Checkin

Replaced rollout switch on gas package unit. Recommend new system due to burners and heat exchanger completely rusty. Inducer and blower motor has high amp draw. Heat is operating at this time.


Phillip S.

Phillip S. Job Checkin

Completed maintnenace on both systems. Customer complaining about noise issue one of vents is rattling tightened vent to ceiling and problem seems to be fixed. Both systems are heating normal at this time. Customer interested in duct cleaning $850 for first and $650 each additional.


Reece W.

Reece W. Job Checkin

Completed maintenance on Amana distinctions furnace.


Reece W.

Reece W. Job Checkin

2 furnace pm check complete. Left customer with replacement filters. Found main level blower motor controller running weak, recommend repair. Main level system operating at 70 ppm co. Upstairs furnace is slightly under fire. Recommend recalibrations. Tested static pressure and got good readings. Dusted furnace cabinets. Systems are heating at this time.


Phillip S.

Phillip S. Job Checkin

Found bad pressure switch in 1998 furnace. Recommend replacing furnace customer wants repair only at this time. Replaced pressure switch and everything is operating at this time!


Paul C.

Paul C. Job Checkin

Replaced blower motor capacitor. System is currently heating.


Reece W.

Reece W. Job Checkin

2 heatpump pm check complete. Changed upstairs filter and main level aprilaire 810 media filter. Upstairs airhandler has a weak blower motor controller. Main level system is in good shape. Systems are heating at this time.