5322 Palmero Ct
Buford, GA 30518
(770) 203-1600

Local Reviews
for pendergrass, ga

Rated 5.0 out of 5 stars based on 7 customer reviews

Fall check up very through.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great service!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Professional

I would recommend Comfort Control to anyone.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Dennis

Great

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service; saved some money with the coupons

Jon explains things very well.

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Very happy with Reese

He was extremely good at his job and checked everything out !!

  • Overall Experience
  • Quality
  • Communication
  • Convenience

Great Service

Brian definitely knows what he is doing and he is very friendly also. Great job Brian

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for pendergrass, ga

Reece W.

Reece W. Job Checkin

Complete 1 system a/c repair and preventative maintenance check. Did not change the filter. Tested mechanical and electrical components, all in good shape. Recommend hard start kit to reduce the load on the compressor to help extend the life of the system. Recommend surge protection to protect the system from power surges. The system is cooling at this time.


Reece W.

Reece W. Job Checkin

1 system A/C preventative maintenance check complete. Changed filter. Tested mechanical and electrical components, all in good shape. Chemically washed condenser coil. The system is cooling normally at this time.


Jon F.

Jon F. Job Checkin

Completed diagnostic found system running a little low on refrigerant. Less than a pound. Put some in got it to correct pressures. Customer worried about leak will come back out in2 months and see if pressures have gone down if so will complete a leak test.


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Jon F.

Jon F. Job Checkin

Completed one system furnace repair and preventative maintenance check. Found outside unit locked out due to short cycle. Reset unit boot it running checked pressures. All looks good thermostat programmed correctly unit running at this time.


Jon F.

Jon F. Job Checkin

Furnace repair call. Reset unit boot it running checked pressures. All looks good. Thermostat programmed correctly unit running at this time.


Jon F.

Jon F. Job Checkin

Completed one system furnace repair and preventative maintenance check. Found the unit is clean with a good capacitor and new filter inside and the outside unit to have good pressure readings good amp readings and capacitor good. Cleaned coils put the unit back together. The customer wanted downstairs unit looked at as well. Checked unit low on refrigerant and worn capacitor customer declined repairs. Cleaned coil and systems running at this time.


Jon F.

Jon F. Job Checkin

Completed 1 system maintenance found unit to be 3 years old and running with no issues. Customer would like garret to come out and talk about estimate to replace bonus room system.


Garrett G.

Garrett G. Job Checkin

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.


Reece W.

Reece W. Job Checkin

Completed 1 heatpump repair and preventative maintenance check. Tested mechanical and electrical components, found no issues. Recommend apco air purifier to prevent mold, kill bacteria, germs, and viruses for improved air quality. The system is heating at this time.


Steve I.

Steve I. Job Checkin

Completed a/c repair and preventative maintenance check. The filter is clean. Cleared drain. Amps and pressures are good. Chemically washed condenser coil. The system is cooling well at this time.


Paul P.

Paul P. Job Checkin

High LRA, hard start kit installed. Low S.C. Added 2lbs of 410a. Dual capacitor out of specific range, replaced it. System is working normally at this time.


Paul P.

Paul P. Job Checkin

High LRA, hard start kit installed. Low S.C. Added 2lbs of 410a. Dual capacitor out of specific range, replaced it. System is working normally at this time.


Paul P.

Paul P. Job Checkin

High LRA, hard start kit installed. Low S.C. Added 2lbs of 410a. Dual capacitor out of specific range, replaced it. System is working normally at this time.


Ta K.

Ta K. Job Checkin

A/c repair call. Tested system and freon is good. Found dirty condenser coil and compressor draws high amps. Reads 16.4 of 21.5 rated amps with outdoor temperature of 81 degree. System is lacking efficiency do to age of system and dirty condenser coil. System will struggle on 90+ degree during peak day. Found starter getting weak. The system is cooling at this time.