1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for azle, tx

Rated 4.9 out of 5 stars based on 80 customer reviews

Excellent Service

Good job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellant Service

Nice young man who went about his business in a professional manner.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Tyler did a great job looking for things and explaining what he found.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional and customer oriented

Adam did a great job of inspecting all the plumbing and he even advise on certain things that will need to be repaired in the near future. Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional and customer oriented

Tyler shows he cares about the customer and is willing to answer questions even if they seem silly. Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

None at this time.


Response from Comfort Experts Inc.:

Thank you so much for the opportunity to help with your Azle TX air conditioning repair.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Austin did a great job. Appreciate his work and advice,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very professional

Very professional arrived as scheduled excellent service fixed the problem job well done!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent!

Good job!


Response from Comfort Experts Inc.:

It was an honor to help with repairing your Azle, TX air conditioning system. Thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent explain everything. Knowledgeable

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!!

Amazing personality and very informative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thanks

  • Overall Experience
  • Quality
  • Price
  • Convenience

Tyler is Fantastic

Great-natured guy. Very helpful with good explanations and super friendly demeanor.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly and knowledable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for azle, tx

Justin  P.

Justin P. Job Checkin

2015 Goodman gas furnace Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Blower Added Customer bought pan treatment Blower motor and wheel were acceptable Evaporator coil was acceptable 2015 Goodman straight electric Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended uv bulb replacement


cody.brooks@acgenius.com

cody.brooks@acgenius.com Job Checkin

Techs Cody and Hunter arrived to Mr. Andrew's home. He showed us inside to the thermostat and indoor access, the system was not blowing air but the outdoor unit was running. We went upstairs and found that the blower motor was not working. we diagnosed a broken blower mount and a failed blower wheel. The customer wanted to order an X-13 and join our maintenance agreement plan. The membership is to be charged to the Visa ending in 3450


Tyler S.

Tyler S. Job Checkin

Tyler S- customer informed me that he didn't call this in. We suspect that a company that goes by the name servalicious that is current doing handman work for him on his porch and other things, May have reported a break to us. But they also went out the same day and fixed said area. Inspected marks work and couldn't see a sign of a leak or break


mark.grant@acgenius.com

mark.grant@acgenius.com Job Checkin

2016 Goodman airhandler Checked and tightened all electrical connections Customer did not have extra filters today Drain has some build up in trap Heat strips were functional and within manufacture range Blower motor and wheel have some dust and dirt build up, blower wires have biological growth build up Evaporator coil was acceptable, condensate pan has biological growth 2016 Goodman Heatpump Checked and tightened all electrical connections Dual run capacitor was out of manufacture range replaced P&L Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended uv system for biological growth


Autumn L.

Autumn L. Job Checkin


Ian C.

Ian C. Job Checkin

System is operating efficiently Coil clean Blower clean Refrigerant levels acceptable Signed up for home Home budget plan Capacitor in range Primary electrical control acceptable Fan motor getting hot, running at peak amps System is running and cooling well Recommended compressor saver


Brock S.

Brock S. Job Checkin

For this cooling tuneup I inspected the furnace and condenser. All equipment measured within manufacturers specs. It was too cold to gauge up and get accurate measurements on refrigerant. I recommended a pan strip, float switch and whole home surge protection. Customer stated he wasn't interested in the recommendations but would call if he decided to move forward in the future.


cody.brooks@acgenius.com

cody.brooks@acgenius.com Job Checkin

Tech Cody arrived to Mr Snider's home. I meant Mr Snider and he showed me inside to the closet indoor unit and showed me where the thermostat was. I started my inspection indoors, the unit is only a few years old and still look to be in great condition upon initial visual inspection. The filter was not in need of replacement the homeowner swapped it out in January, the evaporator coil look clean as well as the blower wheel, the PCS motor was in good condition and the capacitor was intolerance. When taking heat stripes they also came back with intolerance according to manufacturer. I then headed outside to the outdoor coil, and started with washing it down. After washing down I turned it on and let it dry out for 15 minutes before taking my refrigerant readings, the readings came back good and the unit has plenty of charge. I then took an inrush amp test of the compressor and it came back below the manufacturer data tag, there was a hard start kit installed as well as surge protection.


Brock S.

Brock S. Job Checkin

Ransewer machine through cleanout on outside wall cleared stoppage. Also ran small cable through washing machine drain cleared stoppage.


Tyler L.

Tyler L. Job Checkin

Their main panel looks great I found no issues inside of it all the connections were tight The plugs I tested inside were all wired correctly and see eyes were located in patients but when I tested the resistance on their ground rod it was sitting at 3235 so I have given him an estimate for a additional ground rod to lower that resistance and have sent it to his email


Ian C.

Ian C. Job Checkin

Original sold estimate was incorrect Corrected on new estimate and collected no over payment was made Located and fixed leak Cust piping is quest pipe, no warranty can be made


Justin  P.

Justin P. Job Checkin

2015 Coleman airhandler Checked and tightened all electrical connections Changed Customer provided filters Drain had some build up in trap Blower cap was within manufacture range Heat strips were functional and within manufacture range Evaporator coil was acceptable Condensate pan has biological growth Blower wheel was acceptable Blower casing has biological growth Blower wires have biological growth 2015 Coleman straight electric Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended uv system for biological growth, pan treatment for growth in trap and compressor saver for compressor


Mark D.

Mark D. Job Checkin

Straight electric system installed in 2017. All electrical connections are tight with no corrosion. PSC blower motor and capacitor are acceptable. Heat strips are pulling proper amperage. Blower wheel and evaporator coil are clean. Refrigerant levels are in range. Compressor and condenser fan motor are acceptable.


Mark D.

Mark D. Job Checkin

2 system super tune up. Both heat pumps with air handlers installed in 2016. All electrical connections are tight with no corrosion. Ecm blower motors are acceptable. Blower wheels and evaporator coils are clean. All amp draws are in range. Refrigerant levels are in range. All functions normal at this time.


Brock S.

Brock S. Job Checkin

Performed plumbing inspection system in home looks good husband fixed the slow drain on lavatory in master bathroom. Found some corrosion on the pop up assembly under sink in hall bathroom only issue I found at this time. Customer said she will keep an eye on it but if is not leaking right now.