Arrival time was within the scheduled time. Very thorough inspection of furnace and outside AC unit. Have been with this company 15+ years and highly recommend them. All of the technicians are friendly and very professional.
Kellen was outstanding. Very knowledgeable and thorough. He explained everything and answered all of our questions.
Toby arrived on time and gave me a fair estimate on the work that I needed done. We are both Marines so we had some stuff in common right off. From the moment Daniel and Abel arrived, they were professional and polite. They did great work on my HVAC system and we even had some good conversation. Definitely recommend Comfort Experts. One little mistake happened and they were prompt to correct and make it right. Trust-worthy and professional group all around.
He was polite and kept me informed of the task he was doing.
Nathan was very professional and very kind. He took the time to explain everything to me. I wish everyone could be as kind as he was to me. He did a great job
Cody did a wonderful job. He was very through, and very personable. I enjoyed speaking with him while he worked.
Breaker feeding well was tripping on arrival. Tested voltage and continuity in wires feeding pump. no signs of damage or shorting occuring in underground feeder. Seems to be issue with well. Well guy came. Sticking around to make sure there is anything I can do electrically. Well guy had a 230 home line breaker that I quickly installed to help out. Advised customer that we should get that replaced with GE 230 to meet manufactures specifications.
7/3/25 Estimate to replace current gas main line under home to all stub downs to fixtures. Estimate includes all labor and material for installation and all excavation and backfill as well. Need to schedule gas line replacement for Wednesday of next week will be an all day job
Cooling tune up performed today on a 5 year old Trane heat pump. All electrical connections are tight with no corrosion. Primary drain had a blockage and was cleared on this visit. Drain pan treatment was also installed to ensure the drain stays clear. ECM blower motor is acceptable. Biological growth is present inside of the air handler suggest adding a germicidal light to kill the existing biological growth and help clean the air. Compressor and condenser fan motor are acceptable. Outdoor unit was washed and waxed. Sending all estimates to the customer via email.
Install 60k horizontal air handler only
7/1/25 Arrived onsite customer said they left and would not be back till tomorrow
Found leak in evap coil. Unit is not under warranty. System is a 5-ton heat pump has had nothing but issues since he bought the house have given options for repair versus replace since system is not under warranty anymore a bedroom is hot during the summer and hot during the winter possible design for ductwork on that one unit is a train XR
Found drain line clogged up per homeowner. Flush drain line and felt resistant and poured a gallon of water down to verify drain was clear.
Arrived to no cool. Failed 45/5 dual run capacitor was cause of no cool. Replaced capacitor with a premium dual run capacitor and performed function check. System running and cooling the home upon departure.
Arrived to no cool. Loose Schrader valve was causing a small refrigerant leak. Replaced Schrader under warranty and added 16oz of r410a. Performed function check. System running and cooling the home upon departure.
Cooling tune up performed today on a Trane inverter heat pump installed in 2021. All electrical connections are tight with no corrosion. ECM blower motor is acceptable. Blower wheel and evaporator coil are clean. No drain protection has been installed drains are clear. Compressor and condenser fan motor are acceptable refrigerant levels are in range. Outdoor unit was washed and waxed. Customer has two 200 amp panels that service the home. One panel has surge protection but the other does not. Both panels need to have surge protection in order for the home to be protected. Need to add a surge protector and a drain switch to adhere to code compliance.
2019 3t closet upflow hp. Warranty status - all parts 2029. Filter replaced. Drain clear. Coil and blower inspected - clean. Blower capacitor within manufacturer tolerance. UV bulb outside of manufacturer kill rate - off. Slight biological growth present. TESP within manufacturer specifications. DeltaT 12° - ambient 81°. Start capacitor not working as intended. Compressor inrush amperage exceeds manufacturer specifications even with a start capacitor. Dual run capacitor below manufacturer tolerance - replaced. Electrical panel hot spot. Electrical inspection 6/30/25. Sat with homeowner with a pad and paper and shared all information. Homeowner agreed to the immediate fix for peace of mind and asked for emails of estimates to discuss with her son which was not able to be reached on my visit (homeowner attempted multiple times). Husband past away late 2024, this was his getaway home and current owner is deciding what to do with the house and is thinking about proper investment (m
Performed Tune up on 15 year old Carrier. System is running and cooling as should but evap coils are heavily rusted and emergency drain pan is heavily rusted, no drain protection. Talked with customer about new refrigerant and pricing. Customer stated he wanted to wait till system completely fails. Customer signed up for HBPPLAN
Uninstalled p leaking case coil and installed new. Sealed all air leaks pressure tested system and pulled vacuum to sub 500 microns and got charge to recommended superheat Left system in cool
For this job I provided the customer with an inspection of their water softener system. She stated she has never done anything to the unit, as far as upkeep and maintenance. The system is still operational, but would require a treatment to the storage tank. Plus there is salt still inside the water storage tank that would need to be removed and refilled will more salt
Performed Tune up on bedroom system. Bedroom system is functioning as should. Found leak in evaporator coil of main system. Box coil for main system needs to be ordered system is down BOX COIL MODEL - CHPF4860D6DB SERIAL - 2008291344 CONDENSER MODEL - ASX160421FC SERIAL - 2008140988