1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for azle, tx

Rated 4.9 out of 5 stars based on 94 customer reviews

Good guys

Toby arrived on time and gave me a fair estimate on the work that I needed done. We are both Marines so we had some stuff in common right off. From the moment Daniel and Abel arrived, they were professional and polite. They did great work on my HVAC system and we even had some good conversation. Definitely recommend Comfort Experts. One little mistake happened and they were prompt to correct and make it right. Trust-worthy and professional group all around.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service.

He was polite and kept me informed of the task he was doing.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Nathan was very professional and very kind. He took the time to explain everything to me. I wish everyone could be as kind as he was to me. He did a great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job

Cody did a wonderful job. He was very through, and very personable. I enjoyed speaking with him while he worked.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Electrial problem solved

Nathanial fixed my problem quick and efficiently, I'm very satisfied with the finished product.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great educator!

Cody was thorough in troubleshooting my vent problem and I feel like the tutorial on mechanics was helpful and worth the service call!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent work

Justin was great! Very professional and prompt service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Tyler was ver polite and efficient. Job well done

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent!!

Long day, they got it right!! Good job Alex!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Zak was great and very informing! He waited patiently to answer all our questions. Didn’t take long at all to get outback cooling.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Derek was awesome, and very knowledgeable. He was able to answer all my questions I had and I will highly recommend him to my friends and family

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Good job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for azle, tx

Mark D.

Mark D. Job Checkin

Carrier heat pump with air handler installed stalled in 2017. All electrical connections are tight with no corrosion. Heat strips are pulling proper amperage. X13 blower motor is acceptable. Biological growth is present in the air handler installed stalled highly suggest adding a germicidal UV light to kill the biological growth and help sterilize the air. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Reversing valve and defrost control board are working properly. A compressor saver has been installed. Attic insulation is adequate.


Mark D.

Mark D. Job Checkin

2 system heating tune up performed today on a Carrier heat pump with air handler installed in 2017 and a Trane heat pump with air handler installed in 2023. All electrical connections are tight with no corrosion. Both systems have x13 blower motors that are working as they should. Both systems are clean. All heat strips are pulling proper amperage. The auxiliary motor start for the carrier heat pump is very weak and needs to be changed. Customer states that they have a home warranty that will change it. Highly suggest adding a compressor saver to each unit to help with the efficiency and reliability of the systems. The carrier air handler does not have any drain protection. Highly suggest adding drain protection to protect the home from water damage. Refrigerant levels are in range on both units.


Lisa M.

Lisa M. Job Checkin


hunter.gill@acgenius.com

hunter.gill@acgenius.com Job Checkin

Blower wheel is good Blower motor is a psc Axillary motor starter was good There is a wet switch in return Evap coil is good It is a piston Heat strips amp draw was in range Return plenum has dust to be expected Supply plenum has biological growth in it Breakers are good and tight Low voltage was good Contactor was good Auxiliary motor starter was good Low voltage was protected Condenser fan motor is good Compressor was good Inrush amps was 109 Unit has compressor saver Does have surge pro Checked refrigerant in heat mode Unit has leafs at bottom of pan Unit is cleaned and waxed Unit will be good for another year Homeowner would like for the office to send my form in the mail


Justin  P.

Justin P. Job Checkin

2010 American standard airhandler Checked and tightened all electrical connections Customer recently changed filters Drain was clear and draining Heatstrips were functional and within manufacture range Blower motor and wheel were acceptable Evaporator coil was acceptable Heavy amounts of biological growth inside airhandler 2010 American standard heatpump Checked and tightened all electrical connections Dual run capacitor was weak recommend replacing Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended uv system for biological growth inside system, Auxiliary motor starter and compressor saver. Customer signed up for HBPPlan and agreed to replace Auxiliary motor starter


Justin  P.

Justin P. Job Checkin

Customer stated he would wake up to freezing cold house and tstat would be set to 50 in heat. During evaluation found that the schedule was set to run in heat at 50 everyday. Set set schedule to cool to 78 and heat to 74 customers preferred temps. Then turned schedule off


daniel.conchas@acgenius.com

daniel.conchas@acgenius.com Job Checkin

Sold level 3 36k heat pump closet upflow with April air filtration for free ( monthly special continued per Rob Goldate)


Jose  G.

Jose G. Job Checkin

Installer borrowed a tool from the customer. Ended up losing said tool. I have compensated the customer for the lost tool.


Mark D.

Mark D. Job Checkin

11/26/24 During evaluation of furnace I kept smelling gas, opened furnace up to inspect heat exchanger, located what seems to be a potential failure in the heat exchanger which is unsafe. This can cause carbon monoxide to enter the airstream. Inducer motor flue had lots of build up, system would run for 15 mins and then shut off on role out. Tested airstream for carbon monoxide and was getting extremely high readings. Today I shut the Gas valve of to the furnace due to unsafe operating conditions. Need to return with Brian H to further evaluate furnace


adam.brockelman@acgenius.com

adam.brockelman@acgenius.com Job Checkin

Arrived onsite customer had a water heater in hall closet dripping from tmp. Went ahead and flushed water heater replaced tmp valve and piped the drain pan drain. Tested after repairs were Made everything working properly.


Tyler L.

Tyler L. Job Checkin

I will call this customer on the 10th to discuss the estimate being made and to find the best solution to his current issues There is a 30 amp breaker with 12 wire that goes to the dish washer and shop The sub panel needs ground and neutrals separate He would like a European plug for his surround sound A GFCI out side won't resent


Kellen M.

Kellen M. Job Checkin

Complimentary Electrical inspection for Monday 11/25/24 in the afternoon please. 1998 3t r22 electric closet upflow. Completed complimentary inspection for energy efficiency, saftey and reliability. Unit is poorly installed, access to components are against code. Filter system is poor and 1 inch filter is not changed out properly. Evaporator coils have extreme build up, rust, leaks, oil spots and freezes. Blower motor has oil spots present. Blower wheel has extreme buildup. Failing Blower capacitor Only 1 electric heatsrtip functions and that one has very low amps indicating high resistance. Compressor inrush amps exceed manufacturers specifications. Compressor capacitor and fan capacitor are below tolerance. Contactor has heavy scorching and pitting. R22 refrigerant levels are dangerously low. Homeowner was with me for the duration of my visit and i took the time to share evidence, educate and discuss system performance. Homeowner is aware of the all major systems issue


katie c.

katie c. Job Checkin


Tyler L.

Tyler L. Job Checkin

His panel is on the older side but is in great condition no surge protector but connections are tight and recepticals are wired correctly


abel.sifuentes@acgenius.com

abel.sifuentes@acgenius.com Job Checkin

Gave estimates for new water heater. Customer is interested in financing. Could not get husband on the phone she will discuss options tonite and get back with us tomorrow