1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews

Rated 4.8 out of 5 stars based on 3308 customer reviews

Great service and knowledge

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

He was very knowledgeable and thorough. Left everything like it was and was very courteous. He advised us of the increase of prices in coming year.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Joel is who we are asking for all the time now

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good meet

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Tyler is quick and polite. Glad to hear when he’s coming for the maintenance call.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Exemplary Service

Hobson AC/Comfort Experts service exceeded my expectations and believe me with Hobson being my last name we are our biggest critics. Brian, Brady, Joe, Jose, Daniel and Jonathan all showed up and within 3 hours had the new Generac generator set, hooked up and professionally installed. I could not be any more pleased. I’m not looking forward to another electricity outage but if we have one we are a little better prepared. Thank you gentlemen on a job well done. Mr. & Mrs. Hobson Peaster, TX.

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent!

Ryan was great! Prefer him for every visit.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very professional and pleasant!

Wyatt was very informative and explained things that we could understand what was needed to be done.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job

As always the work was done with care and efficiently.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Good

  • Overall Experience
  • Quality
  • Price
  • Convenience

Blake was excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

The guys were great and very professional. I love their work ethic.

My experience was great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great, Prompt, Fast Service!

Matt and his associate where very understanding, empathetic, and prompt in his service. I highly recommend this company in general! I ended up having to replace my entire system a few weeks before Christmas. Everyone who we have had contact with in this company have been lovely and HONEST! Which is difficult to find these days!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations

Matt B.

Matt B. Job Checkin

12/8/22 Upon arrival, system was found not cooling. Checked for leaks on indoor coil and found none. Checked filter, filter good. Airflow is OK. Checked freon, freon levels are good. Found low limit switch was tripped three times throwing the L1 code. Reset the board, and cooling operating normally. my guess is that the low temperatures outside tripped the switch. But the pressures won't be enough to trip the low pressure switch. System was left cooling with a 20 dt


Steven S.

Steven S. Job Checkin

Upon arrival for tune up system off. Customer states tree limb fell and bent vent piped and damaged cap. Turn unit on. Furnace came on. No debris inside of inducer. Inducer has good amp draw. Flame being properly pulled through. Blower and coil clean. Drain line clear. Inspected outdoor unit. Fan and compressor amp draw within unit specifications. Capacitor within tolerance. Refrigerant pressure good. Recommended repair of pipe, collar and cap for vent pipe. Customer agreed. Will order vent pipe, collar and cap and return for proper repairs.


jonathan.cox@acgenius.com

jonathan.cox@acgenius.com Job Checkin

Panel looked good where up to code


Tyler B.

Tyler B. Job Checkin

STU performed today, outdoor unit refrigerant levels are good at this time and the dual run capacitor to testing within manufacturer specifications, indoor unit filter is clean and primary drain line is clear at this time. Heat strips are pulling proper amperage and the system is working as it should in both heating and cooling, uv bulb burned out, customer purchased replacement


Wyatt C.

Wyatt C. Job Checkin

HTU 2008 Amana Air Handler UV bulb was functional Heating elements were functional and within manufacturer range Evaporator coil was acceptable Blower motor and wheel were acceptable Electrical connections were acceptable Changed the filter for customer Drain was clear and draining 2017 Amana Heat Pump Tightened up some connections Dual capacitor was within manufacturer range Electrical connections were acceptable Primary electrical contactor was acceptable Washed the unit from inside out Waxed the top of the unit Fan blades and motor were acceptable


riley.hobson@acgenius.com

riley.hobson@acgenius.com Job Checkin

Install 36k heat pump upflow with high efficiency filtration, new unit platform, digital thermostat and drain switch


riley.hobson@acgenius.com

riley.hobson@acgenius.com Job Checkin

2 system home. Gas furnaces with straight cool condenser. Main home installed in 2014. Gas flow and igniter are in range and operating as they should. Heat exchanger is good. Limit switch is functional. PSC blower motor is good. Blower wheel and evap coil are clean. 45/5 dual run capacitor and contactor are good. Needs 20x24x5 filter Back apartment: installed in 2014. Gas flow and igniter are in range and operating as they should. Heat exchanger is good. Limit switch is functional. PSC blower motor is good. Blower wheel and evap coil are clean. 35/5 dual run capacitor and contactor are good.


Matt B.

Matt B. Job Checkin

12/8/22 Upon arrival found system heating and cooling properly. Tested amp draws and checked capacitor. System needs a compressor saver next year and I told the customer he would need to get one. Recommended UV system and customer declined. Recommended surge protector and customer declined. Coil was pretty clean and we were unable to wash it due to rain. Checked delta and it was at 20. Drains were clear and switched filter. No further issues found


Tyler B.

Tyler B. Job Checkin

STU performed today, outdoor unit refrigerant levels are good at this time and the dual run capacitor to testing within manufacturer specifications, indoor unit filter is clean and primary drain line is clear at this time. Heat strips are pulling proper amperage and the system is working as it should in both heating and cooling


Kellen M.

Kellen M. Job Checkin

AH complete Customer needs to replace his 310 Aprilaire filter Customer had a UV light that I replaced to provide value of our services Customer has a weak dual run capacitor outside of manufacturer tolerance per data tags. I discussed to the customer the importance of replacing the item, declined work.


Dennis C.

Dennis C. Job Checkin

10 year old Goodman heat pump: system is operating normally at this time.


Joel B.

Joel B. Job Checkin

Did a AH on 7 yea old American Standard and 7 year old American Standard condenser and 1 year old Lennox furnace, checked capacitors, checked filters, flushed drains, checked flame sensors and ignitors, checked inducer motors,checked pressure switches, checked safety switches, found dual run capacitor was weak on south side condenser unit, recommended a membership, compressor saver, and replacing the dual run capacitor,customer said they had to talk to her husband and they would give us a call back about the membership and dual run capacitor


Ryan S.

Ryan S. Job Checkin

Performed Stu, System operation is normal. Changed filter cleaned condenser


Steven S.

Steven S. Job Checkin

Upon arrival for stu system on and heating. Inspected indoor unit. Changed filter. Drain line clear. Blower has dust buildup. Coil has slight corrosion buildup. Inducer motor amp draw good. Flame sensor and ignitor clean. Inspected outdoor unit. Fan and compressor amp draw within unit specifications. Refrigerant pressure good. Capacitor within tolerance. Board functioning correctly.


Jordan B.

Jordan B. Job Checkin

Thoroughly performed a tune up for a 2014 Lennox split system, washed condenser coil out, checked heat pump components, dual run good, amps all within specs, evaporator coil is extremely dirty, filter needs to be a 20X25 and the blower cap is below specs. Recommended a Level 2 duct cleaning, UV system, coil cleaning with acid and a blower capacitor. Customer will talk to his wife and call back if they decide to do any recommendations.