1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for boyd, tx

Rated 4.9 out of 5 stars based on 17 customer reviews

Excellent Service

Ian performed a complete diagnostic and said everything is running the way it should. Said he would stop by in a couple of days to check it.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

He came in and got straight to work! Was professional and timely.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Do a wonderful job cleaning our AC unit. I would like to have Ian come next year for our tuneup.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Electric Service

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent services

Answered all my questions

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service on a Sunday!

Heater stopped at 4am with temps in the 20's outside. Ian and Mark found the problem quickly and got it going again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Dangerously cold weather was in the forecast and we got same afternoon service for the heat pump. Blake was a Professional and found the problem quickly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick. Efficient service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent work

Did a great job getting our A/C working again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Tech Provided Excellent Service!

Appointment was rescheduled twice. Service tech was supposed to be here in early morning but did not come out until late afternoon. Service Center never called to let us know what time someone would be out after the morning tech was delayed. Once service tech arrived he was respectful, friendly and efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Arrived on time, friendly service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very considerate and professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great technician & servuce

Devyn listened to the issues & was very thorough in discovering & repairing the problems.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very thorough

Devyn was very thorough in his evaluation and found some issues that, if left alone, would potentially cause my AC to stop working.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for boyd, tx

Ian C.

Ian C. Job Checkin

Upon arrival system was on and operating, found that the compressor saver was compromised. Replaced under warranty. Running amps 8.3 Refrigerant acceptable superheat 10 subcool 7.3 IAT 71 Upon further inspection I found that the air handler control board was casting for an update. Updated board, reset system. Confirmed system start up was acceptable, Amp draws acceptable, Refrigerant levels acceptable. System is on and operating efficiently Requested that cust does not flip breaker to outdoor system if this happens again. If no more issues occur after one week I recommend scheduling a follow up visit to run system diagnostic test when temp outdoor is 95+ preferably around 1


Ian C.

Ian C. Job Checkin

System was on and working upon arrival Cust said breaker on disconnect kept tripping Found loose wire on breaker and a loose ground connection Replaced breaker with proper sized breaker and tightened connections System is on refrigerant acceptable Amp draws acceptable, no codes on boards


Mark D.

Mark D. Job Checkin

Arrived to water leaking from the emergency drain pan and through the ceiling. Primary drain was blocked at the drain pan. Cleared blockage and poured vinegar through the drain. Added a drain treatment strip to keep the drains clear. Vacuumed the water from the emergency drain pan. CWF Restoration is meeting with customer tomorrow morning about the water damage to the ceiling.


Ian C.

Ian C. Job Checkin

Upon arrival I found Cust condensation drain pan was not level causing water to build up in airhandler. Lots of biological growth in airhandler Primary drain was clogged Cleaned biological growth and cleared drain Installed uv germicidal light System is on and operating efficiently Refrigerant levels acceptable Poured 5 gallons of water through drain pan to see confirm properly draining


Justin  P.

Justin P. Job Checkin

2011 Goodman airhandler Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Blower motor and wheel were acceptable Evaporator coil has some build up of dust and dirt Condensate pan has some growth 2011 Goodman Heatpump Checked and tightened all electrical connections Dual run capacitor was within manufacture range Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended uv bulb replacement, compressor saver and pan strip


Tyler S.

Tyler S. Job Checkin

05/13/24 TS- no issues, waterheater is 9 years old but in good condition. All inside fixtures are in good condition


Mark D.

Mark D. Job Checkin

Propane furnace with straight cool condenser installed in 2019. All electrical connections are tight with no corrosion. Refrigerant levels are in range. Blower motor, compressor and condenser fan motor are acceptable. Customer complained of poor air flow in back bathroom. We installed the ductwork. I cut down a support in the duct in order to straighten the path of the air and air flow improved slightly.


Lisa M.

Lisa M. Job Checkin

Completed hvac maintenance.


Ian C.

Ian C. Job Checkin

Blower wheel is dirty Coils are dirty Ducts are dirty System is operating efficiently Refrigerant levels acceptable Recommended to cust lvl 2 duct cleaning or blower wheel clean and coil clean Need to follow up, system is operating efficiently at this time. Need to clean indoor system


Justin  P.

Justin P. Job Checkin

Evaporator coil and line set were freezing, leak tested both indoor and out door. Couldn't find leak, system also have heavy amounts of biological growth that customer is concerned with. Customer stated she doesn't want it in her home anymore, causing heavy allergies. Setup appointment for CA for 3/19/24 10-2.


Tyler L.

Tyler L. Job Checkin

No service fee because this is the same problem I've been addressing if it's not fixed this time I will be getting into contact with their service provider


Tyler L.

Tyler L. Job Checkin

Tyler L has completed electrical rec Work I also tightened up the lug on the main neutral because his lights were flickering every time relatively big appliance was used


Tyler L.

Tyler L. Job Checkin

I will be returning to this customer to put in a surge protector and check out wax lights are flickering on February 19th


Autumn L.

Autumn L. Job Checkin


Tyler L.

Tyler L. Job Checkin

Tyler L completed an electrical evaluation and I did find that he had no surge protector but he was not interested in gettingting one at the moment