Marshall G. My technician wonderful! Very knowledgeable and did everything in his power to restore the a/c.
6/14/25 Will return to complete work
We will replace fill valve and flapper in hall bath toilet. High water bill. Tech found hall bath toilet was hanging up when flushed. Rebuilt both toilets and checked meter. Meter is showing no leaks at this time
On arrival system running and cooling as intended. Indoor unit passed all electrical testing. Scoped supply plenums and heat strips to try to identify the cause of the breaker tripping at the panel in heating but found no issues and had no issues in heat mode. Outdoor unit passed all electrical testing but the compressor overamped on start up. Recommended a compressor saver kit to reduce wear and tear and increase life of compressor. Customer would like an electrical and plumbing visit scheduled.
4/30/25 Pausing call, need to return tomorrow to charge system and fix field weld, do decay test etc. Please call customer tomorrow to do financing and schedule my return visit tomorrow afternoon.
Repaired ceiling fan by removing defective remote controller. Installed wwsp. Installed unit surge protection on condenser.
Replaced pop up assembly in master bathroom. Also replaced toilet seat in hall bathroom, tested after repairs were made everything working properly.
Today we showed up for a complimentary Plumbing evaluation set from another trade upon arrival the homeowner informed us that the toilet wasn't flushing as it should we inspected it and yes it's draining slowly and if you run water down the sink you get bubbles out the toilet so we started looking at the vent we climbed on the roof ran the camera down as far as we could hit stop it where the PVC pipe meets the cast iron you can tell previous repairs have been made throughout the home however the true solution to her problems is to replace all of the cast iron underneath her home however this is not something that she can afford she did mention that she has a Home Warranty company and was just looking to get us to point out the problem we left her some estimates with some options so that we could dig deeper and get a clear understanding as to this one in particular problem but again the overall solution is to gut all of the old dilapidated cast iron and replace it with schedule 40 PVC
For this super tune-up we inspected the customer's air handler and condenser. System is 15 years old the dual run capacitor is out of tolerance and will need to be replaced as well as the contactor is both buzzing and pitted which is indicative of potential failure. When we gauged up we had a five degree and a 34° super heat indicating that the system is both low on refrigerant and has a restricted metering device. We leak searched the evaporator coil and found the leak. We spoke with the customer about what we found however at this time they want to wait on replacing. At this time they do not believe they have the funds to replace. Customer wants to have a plumber come out tomorrow to look at her bathroom toilet as it is slow to drain after a few flushes.
Need to return Tuesday to complete work will have parts when I come back Tuesday
And came to house for electrical inspection.Talk about the breaker that needs to be swapped and swapped that out and then talk about adding a search for tector and also swapping out smoke detector batteries.But customers gonna try her grandson first
Performed super tune up Washed condensor and tightened connections Replaced filter Delta 21 All cooling and heating components are in tolerance Reccomended soft start or compressor saver kit Reccomended IAQ200 UV Homeowner will go over information and give office a call for promotion Service fee advised for return System left on heat at exit
Found no power to furnace wire to fused switch had broken off cut stripped and reattached wire furnace is functioning.
Super tune up on 2021 amana gas furnace and air conditioner checked all components in heating and cooling recommend replacing uv bulb
On this job I inpected a gas furnace. The system is a little dirty but nothing out of tolerance. I changed the filter today and talked to her about updating her gas line.