Derek was awesome . He knows his stuff and immediately pinpointed the root problem and pointed me to the product to hopefully prevent the same problem from recurring .
Arrived on time, got right to work, and completed in less time than I expected. Pleasent young men.
The crew did an excellent job installing the replacement main unit after a warranteed unit failed and they had us back up in less than a day from first call.
Good guy. Saved me a little money
Thank you feel better knowing that my propane heater is working correctly
Customer wanted quote on a generac generator for home
Arrived to system blowing hot air. Found that the plug going to the coil on the reversing valve had come loose. Tightened plug back and secured it. Washed the outdoor coil to ensure proper airflow over the condensing coil. Performed function check. System running and cooling upon departure.
Blockage in drain was preventing the system from cooling the business. Cleared drain and confirmed clear with 2 gallons of water down the drain. System running and cooling upon departure.
2 system super tune performed today. Upstairs system is a Goodman straight electric system installed in 2024. Downstairs system is a Goodman straight electric system installed in 2022. All electrical connections are tight with no corrosion. Refrigerant levels are in range. Both blower wheels and evaporator coils are clean. Compressors and condenser fan motors are acceptable. Both outdoor units were washed and waxed.
Replaced outdoor TXV and bi flow filter drier. Moved filter drier from the outdoor unit to upstairs in the attic. Replaced recovered refrigerant. System running and cooling the home upon departure.
NOT A CALLBACK. Customers well switch was functioning when I arrived, he did not want to change it today but said he would get parts himself and call us again.
Customer had busted crimp ring on water line above water heater. I successfully replaced the broken ring and small section of pex.
Upon arrival system was tripped on a pressure switch. Reset system and watched pressure slowly drop on low side. Found indoor filter at one of the filter grills 100% blocked. Removed filter and pressures improved. Found no other issues at this time
Customer states that the downstairs system is not cooling the home. Technician discovered the system to be very low on refrigerant. Performed a leak search and found a significant leak in the evaporator coil. Coil has been documented with pictures and a video. Outdoor unit was washed and waxed. Customer did not have a filter to change out. Upstairs system is a Payne straight electric system installed in 2022. All electrical connections are tight with no corrosion. Blower wheel and evaporator coil are clean. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Outdoor unit was washed and waxed. Customer has a home warranty company that they would like to do the repairs on the leaking coil. Customer declined repairs at this time.
Estimate for customer supplied softener. This is a brand new home and customers just moved in. Water has been ran for softener but drain will need to tie into a vent in the attic. Customer wants to wait on builder to install unit
We will install a new customer supplied rinnai tankless water heater in existing box on outside wall of guest house. This will include service valves and start up. Warranty on installation only. No warranty on c/s parts
Upon technicians arrival technician found downstairs unit and high-pressure lock out homeowners state that they are running the system and heat yesterday technician reset the system and found nothing wrong with it. Technician had the system running for an hour and all the readings looked perfectly fine. Technician did find a leak and evaporated coil for the upstairs and has a CA coming out today for it.
2018 Amana Airhandler Checked and tightened all electrical connections Changed Customer provided filter Drain was clear and draining Heatstrips were functional and within manufacture range Blower motor and wheel were acceptable Evaporator coil was acceptable 2018 Amana Heatpump Checked and tightened all electrical connections Dual run capacitor weak replaced under P&L Primary electrical unit was acceptable Refrigerant levels were acceptable at this time Fan blades and motor were acceptable Condenser coil was acceptable Washed Condenser coil from inside out Cleared debris out of unit Waxed top of unit Recommended compressor saver and unit surge protection
I have finished my rec work and found the cause of the problem, I have rewired a splice that was under the house