1412 Greenwood Road
Weatherford, TX 76008
817-596-4808

Our Top Cities


Local Reviews
for lipan, tx

Rated 5.0 out of 5 stars based on 32 customer reviews

Repair

Unit is working well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Cody did a great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

good guy very thorough

  • Overall Experience
  • Quality
  • Price
  • Convenience

Sales presentation

Presentation was professional. Well done.

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

Derek was awesome . He knows his stuff and immediately pinpointed the root problem and pointed me to the product to hopefully prevent the same problem from recurring .

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Arrived on time, got right to work, and completed in less time than I expected. Pleasent young men.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Super service.

The crew did an excellent job installing the replacement main unit after a warranteed unit failed and they had us back up in less than a day from first call.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Same day service and accomplished quickly.0⁰

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very professional . Knew what he was talking about

Good guy. Saved me a little money

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Thank you feel better knowing that my propane heater is working correctly

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Nice job

Very helpful tech Zack found issues and addressed quickly and well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent!

Alec was very knowledgeable, kind and thorough!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lipan, tx

Justin  P.

Justin P. Job Checkin

Nest thermostat would cycle the fan on and off but not the Heatpump when it should. Changed to Honeywell programmable thermostat and found no other issues at this time Per Brian H, no charge


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

We will dig up water line and install customer supplied bury hydrant for stock tank. No warranty on c/s parts 7/24/25 WG Dug up water line by fence in pasture and installed bury hydrant. Ground is very rocky and difficult to dig. We were able to bury it 2 ft deep and secured with t post. No warranty on c/s parts


Mark D.

Mark D. Job Checkin

Cooling tune up performed today on a one year old Lennox h at pump with air handler. All electrical connections are tight with no corrosion. ECM blower motor is acceptable. Blower wheel and evaporator coil are clean. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Outdoor unit was washed and waxed. Highly suggest adding a whole home surge protector to the main panel to protect the home and the appliances in the event of a surge.


wade.gordzelik@acgenius.com

wade.gordzelik@acgenius.com Job Checkin

No heat strip operation. Everything amps below threshold. Crawled into attic found signs of mice. Couldn't replicate problem.


Mark D.

Mark D. Job Checkin

Arrived to no cool on upstairs unit caused by a tripped drain switch. Recall on previous technician for failing to fully clear the drain. Performed function check. Both system running and cooling upon departure.


Kellen M.

Kellen M. Job Checkin

Homeowner use to do HVAC back in the day. He took me right to the issue. Primary drain line blockage. Cleared, pushed and pulled, gallon of water down and chased with customer supplied bleach. Had two customer supplied UV bulbs that did no fit current system. Encouraged drain pan treatment strips. Upstairs System fully functional.


Kellen M.

Kellen M. Job Checkin

Homeowner use to do HVAC back in the day. He took me right to the issue. Primary drain line blockage. Cleared, pushed and pulled, gallon of water down and chased with customer supplied bleach. Had two customer supplied UV bulbs that did no fit current system. Encouraged drain pan treatment strips. Upstairs System fully functional.


Kellen M.

Kellen M. Job Checkin

Homeowner use to do HVAC back in the day. He took me right to the issue. Primary drain line blockage. Cleared, pushed and pulled, gallon of water down and chased with customer supplied bleach. Had two customer supplied UV bulbs that did no fit current system. Encouraged drain pan treatment strips. Upstairs System fully functional.


Kellen M.

Kellen M. Job Checkin

Homeowner use to do HVAC back in the day. He took me right to the issue. Primary drain line blockage. Cleared, pushed and pulled, gallon of water down and chased with customer supplied bleach. Had two customer supplied UV bulbs that did no fit current system. Encouraged drain pan treatment strips. Upstairs System fully functional.


Mark D.

Mark D. Job Checkin

Arrived to no cool due to an intermittent low voltage short. Technician found a popped 5 amp fuse in the indoor control board. Replaced fuse and added a fuse to each low voltage circuit in order to track down the short. System operating at time of departure. This is an intermittent issue and technician will not know which low voltage circuit is causing the short until the unit fails again.


Don S.

Don S. Job Checkin

B ok vovivov


abel.sifuentes@acgenius.com

abel.sifuentes@acgenius.com Job Checkin

Arrived at customer's house turned on system. Put gauges on r 22 system and saw low pressures was told that they have been told that there are leaks in the evaporator coil. I went up stairs to verified leaks in evaporator coil also asked about any air flow issues in the house due to house being added on master bedroom has horrible air flow and a return in the utility closet. Also wants to talk about redoing lindset due to poor Installation of line set.


abel.sifuentes@acgenius.com

abel.sifuentes@acgenius.com Job Checkin

Arrived at location. Turned on system and found outdoor unit humming and fan spinning. Removed panel and found the compressor side of the capacitor dead. Informed customer of different options. Replaced the capacitor and then verified proper amps on systems and left system cooling.


jani.gonzales@acgenius.com

jani.gonzales@acgenius.com Job Checkin

Replace upstairs system with 24k hz heat pump with high efficiency filtration and code kit


Mark D.

Mark D. Job Checkin

Apon arrival found no power to thermostat. Opened up air handler and found 5amp fuse blown. Replaced fuse and verified proper operation of system in cooling. Found thermostat wire being pinched by the door of air handler. Re routed wire and left system cooling properly.