Best service provider I’ve used. They returned my calls promptly and answered all questions. They scheduled my appointment according to my needs. Technician, Dennis, was on time and very nice. He answered all the f my questions and gave me options to consider. One of the best parts was he left everything clean and in place! He also secured my doors upon leaving. I was very pleased.
I think this HVAC company is top notch
Located and fixed water leak above water heater, pressure tested no leaks Thank you for choosing comfort Experts. Vedz zxxds
Barn apartment mini split. All electrical connections are tight with no corrosion. Compressor and condenser fan motor are acceptable. Refrigerant levels are acceptable. Studio mini split. All connections are tight with no corrosion. Compressor and condenser fan motor are acceptable. Refrigerant levels are in range. Customer only has one remote for all three heads and it works intermittently. Tech was finally able to get all three heads to turn on and cool at the same time. Customer needs new remote to control the heads. Main home. Gas furnace with straight cool condenser. All electrical connections are tight with no corrosion. Blower wheel and evaporator coil are clean. PSC blower motor and capacitor are acceptable. Refrigerant levels are in range. Compressor and condenser fan motor are acceptable.
2 year old Amana heat pump with air handler. All electrical connections are tight with no corrosion. All amp draws are in range. Blower wheel and evaporator coil are clean. Refrigerant levels are in range. Daiken mini split. All amp draws are in range. Refrigerant levels are acceptable. Filters and condenser were cleaned.
3/18/24 Factory didn't install jumping wire for charging circuit, fixed issue will need to charge for 24 hours then Mark W to return on 3/19/24 to check on it
Arrived to no lights on the generator. Tested battery to find that it had 0 voltage. Mark W to return tomorrow with a replacement battery. No service fee today per Mark W.
Replaced breaker ran system cycles. TRANE Main living area system is running as should. Left system in cool mode.
Upon arrival system was down, found pass through breaker had failed. Need pass through breaker ordered payment collected.
2/21/24 Will need to return Monday the 26th to fix water leak and run wire
Put dryer plug back like it was. The plug works but is not safe dryer working. All done. Customer not here at this time
Upon arrival found outdoor unit to not be getting low volt power checked indoor fuse and found it to be intact checked for low voltage from unit to drain switch and there was 24 volts checked power from drain switch to outdoor and tstat wire there was no voltage Checked continuity on drain switch and found it to have none Replaced drain switch unit is now running as intended
Post is set. Install pending date Install 14kw Generac generator and install pressure tank and jet pump on customer supplied water tank
1/31/24 Having to order special pipe tool for repair will need to reschedule
Reschedule for Wed 01/31/24 first call for water repair