7001 Lark Lane
Sanford, NC 27332
(919) 777-1777

Local Reviews
for pittsboro, nc

Rated 4.9 out of 5 stars based on 16 customer reviews

Comfort First Generator Installation

Joel Worsham and his team gave us top notch information about, installation of, and instruction on our new standby home generator system. I highly recommend these professionals.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Joel and the team provided great service and very easy process from initial call to installation. They answered all questions, very professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

nice guy

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

They were both very professional and did neat work

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good installation

Installed promptly and professionally.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Relating to Peyton

Peyton was a pleasure to have in my house during the majority of the installation. He was very professional and I would highly recommend him.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional and honest all around!

I just spent two afternoons being educated on how to make my house a home. For three years I have been wrapped in blankets and overpaying my utility bill. I decided to investigate switching from heat pumps to gas. Bill Smart took so much time to help me understand what was not working well and what my options were. I decided to move forward and have scheduled the installation in just over a week. I can’t wait to enjoy my new home. Bill was extremely knowledgeable and professional, I would recommend him and Comfort First to everyone.

  • Overall Experience
  • Quality
  • Price
  • Convenience

New A/C install

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Customer Service

Cody did a great job of explaining everything in detail as to what was wrong with my HVAC system and even answered several texts to help me identify issues after hours. Overall, I rate his customer service 5 stars!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Very friendly, good at explaining technical terms, cared about saving us money and not doing any services that weren't necessary.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Tony was prompt, courteous, and respectful. He quickly diagnosed the problem and replaced a blown transformer. Hi was both professional and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Heat Pump Install

  • Overall Experience
  • Quality
  • Price
  • Convenience

Heat Pump Install

Sean and Carlos were very professional and respectful of the property. Unit was installed and operational by midday.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for pittsboro, nc

James M.

James M. Job Checkin

Removal of water filter


tyler s.

tyler s. Job Checkin

Installed split heat pump in attic


Thomas H.

Thomas H. Job Checkin

Trane gas furnace. Repaired low voltage issue for dehumidifier and humidifier


Manuel M.

Manuel M. Job Checkin

Complete 1 System Amana Gas Pak: Checked tstat and air filter. Replaced air filter. Checked Blower Motor amp draw and run cap. Checked electrical connections. No CO detected. Burners are clean. Checked amparage on draft motor. All safety switches are on great condition. System is running great at this time. HO Signed Epa Agreement. M


Manuel M.

Manuel M. Job Checkin

Incomplete 2 Systems. 2 EPA Heating Maintenances: US Amana HP Split System: Checked tstst and air filter. Checked heat strips and made sure they were on. Checked blower motor amp draws and run cap. Inspected evap coil. Checked all wiring at the AH. Checked compressor and cfm amp draws. Checked dual cap. Checked all wiring at the condenser. Checked pressures. Tested defrost board. Condenser coil is clean. System is running great st this time. DS Duel Fuel Trane Gas Pak: Checked tstst and air filter. Checked heat strips and made sure they were on. Checked blower motor amp draws. Inspected evap coil. Checked all wiring. Checked compressor and cfm amp draws. Checked dual cap. Checked pressures. Tested defrost board. Condenser coil is clean. Couldnt complete maintenance on the gas side. Found bad inducer motor. It needs to be replaced. Making a really loud noise and vibrating real bad. Talked to HO about the situation. She authorized me to order inducer motor and get it replaced. Charger HO


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems 2 AHS Heating Maintenances. US Lennox 90% Gas Furnace: cycled system. Checked tstat and air filter. Checked Blower Motor amp draw and run cap. Checked electrical connections. No CO detected. Burners are clean. Cleaned Flame sensor. Checked amparage on draft motor. All safety switches are on great condition. System is running great at this time. DS Lennox 90% Gas Furnace: cycled system. Checked tstat and air filter. Checked Blower Motor amp draw and run cap. Checked electrical connections. No CO detected. Burners are clean. Cleaned Flame sensor. Checked amparage on draft motor. All safety switches are on great condition. System is running great at this time.


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems worked on DS Trane Gas Furnace: HO stated system was not coming on. Found system locked out. Found butners rusted out. Cleaned them up. Also found the botttom orifice almost clogged up. Clear that one up and the other 2 as well. Cycled system a few times. System came on and stayed running every time. System is running great at this time .


Manuel M.

Manuel M. Job Checkin

Complete 1 System HP Pak Unit EPA Heating Maintenance: Checked tstst and air filter. Checked heat strips and made sure they were on. Checked blower motor amp draws and run cap. Inspected evap coil. Checked all wiring at the AH. Checked compressor and cfm amp draws. Checked dual cap. Checked all wiring at the condenser. Checked pressures. Tested defrost board. Cleaned condenser coil. System is running great at this time.


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems EPA Heating Maintenance: RightSideOfHouse Carrier 90% Gas Furnace: Checked tstat and air filter. Checked blower motor amp draw. Checked electrical connections. Inspected evap coil. No CO detected. Burners are clean. Cleaned Flame sensor. Checked amparage on draft motor. All safety switches are on great condition. System is running great at this time. LeftSideOfHouse Trane HP Pak Unit: Checked tstst and air filter. Checked heat strips and made sure they were on. Checked blower motor amp draws and run cap. Inspected evap coil. Checked compressor and cfm amp draws. Checked dual cap. Checked all wiring at the condenser. Checked pressures. Tested defrost board. Cleaned condenser coil. System is running great st this time.


Manuel M.

Manuel M. Job Checkin

Incomplete 2 Systems worked kn DS Trane Pak System: HO stated system was not cooling. Found system evap coil frozen. Will need to reschedule to come back when system is thawed.


Manuel M.

Manuel M. Job Checkin

Complete 1 System Amana 80% Gas Furnace: EPA Heating Maintenance: cycled system. Checked tstat and air filter. Checked electrical connections. Checked blower motor amp draws. Checked run cap. Inspected evap coil. No CO detected. Burners are clean. Cleaned Flame sensor. Checked amparage on draft motor. All safety switches are on great condition. Checked draft motor. System is running great at this time.


Manuel M.

Manuel M. Job Checkin

Complete 1 System Amana 90% Gas Furnace: EPA Heating Maintenance: cycled system. Checked tstat and air filter. Checked electrical connections. Checked blower motor amp draws. Inspected evap coil. No CO detected. Burners are clean. Cleaned Flame sensor. Checked amparage on draft motor. All safety switches are on great condition. Checked draft motor. System is running great at this time.


Tony M.

Tony M. Job Checkin

Goodman replaced suction valve


Carl T.

Carl T. Job Checkin

Carrier mini split checked system found E1 code due to bad contral board need ro replace contral board


Manuel M.

Manuel M. Job Checkin

Complete 1 System Trane HP Split System: Replace condensate pump. Made sure clear line was clear. System is running properly at this time.