7001 Lark Lane
Sanford, NC 27332
(919) 777-1777

Our Top Cities


Local Reviews
for pittsboro, nc

Rated 4.9 out of 5 stars based on 16 customer reviews

Comfort First Generator Installation

Joel Worsham and his team gave us top notch information about, installation of, and instruction on our new standby home generator system. I highly recommend these professionals.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Joel and the team provided great service and very easy process from initial call to installation. They answered all questions, very professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

nice guy

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

They were both very professional and did neat work

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good installation

Installed promptly and professionally.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Relating to Peyton

Peyton was a pleasure to have in my house during the majority of the installation. He was very professional and I would highly recommend him.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional and honest all around!

I just spent two afternoons being educated on how to make my house a home. For three years I have been wrapped in blankets and overpaying my utility bill. I decided to investigate switching from heat pumps to gas. Bill Smart took so much time to help me understand what was not working well and what my options were. I decided to move forward and have scheduled the installation in just over a week. I can’t wait to enjoy my new home. Bill was extremely knowledgeable and professional, I would recommend him and Comfort First to everyone.

  • Overall Experience
  • Quality
  • Price
  • Convenience

New A/C install

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Customer Service

Cody did a great job of explaining everything in detail as to what was wrong with my HVAC system and even answered several texts to help me identify issues after hours. Overall, I rate his customer service 5 stars!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for pittsboro, nc

Manuel M.

Manuel M. Job Checkin

Complete 1 System Amana Gas Pak: Checked tstat and air filter. Replaced air filter. Checked Blower Motor amp draw and run cap. Checked electrical connections. No CO detected. Burners are clean. Checked amparage on draft motor. All safety switches are on great condition. System is running great at this time. HO Signed Epa Agreement. M


Manuel M.

Manuel M. Job Checkin

Incomplete 2 Systems. 2 EPA Heating Maintenances: US Amana HP Split System: Checked tstst and air filter. Checked heat strips and made sure they were on. Checked blower motor amp draws and run cap. Inspected evap coil. Checked all wiring at the AH. Checked compressor and cfm amp draws. Checked dual cap. Checked all wiring at the condenser. Checked pressures. Tested defrost board. Condenser coil is clean. System is running great st this time. DS Duel Fuel Trane Gas Pak: Checked tstst and air filter. Checked heat strips and made sure they were on. Checked blower motor amp draws. Inspected evap coil. Checked all wiring. Checked compressor and cfm amp draws. Checked dual cap. Checked pressures. Tested defrost board. Condenser coil is clean. Couldnt complete maintenance on the gas side. Found bad inducer motor. It needs to be replaced. Making a really loud noise and vibrating real bad. Talked to HO about the situation. She authorized me to order inducer motor and get it replaced. Charger HO


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems 2 AHS Heating Maintenances. US Lennox 90% Gas Furnace: cycled system. Checked tstat and air filter. Checked Blower Motor amp draw and run cap. Checked electrical connections. No CO detected. Burners are clean. Cleaned Flame sensor. Checked amparage on draft motor. All safety switches are on great condition. System is running great at this time. DS Lennox 90% Gas Furnace: cycled system. Checked tstat and air filter. Checked Blower Motor amp draw and run cap. Checked electrical connections. No CO detected. Burners are clean. Cleaned Flame sensor. Checked amparage on draft motor. All safety switches are on great condition. System is running great at this time.


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems worked on DS Trane Gas Furnace: HO stated system was not coming on. Found system locked out. Found butners rusted out. Cleaned them up. Also found the botttom orifice almost clogged up. Clear that one up and the other 2 as well. Cycled system a few times. System came on and stayed running every time. System is running great at this time .


Manuel M.

Manuel M. Job Checkin

Complete 1 System HP Pak Unit EPA Heating Maintenance: Checked tstst and air filter. Checked heat strips and made sure they were on. Checked blower motor amp draws and run cap. Inspected evap coil. Checked all wiring at the AH. Checked compressor and cfm amp draws. Checked dual cap. Checked all wiring at the condenser. Checked pressures. Tested defrost board. Cleaned condenser coil. System is running great at this time.


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems EPA Heating Maintenance: RightSideOfHouse Carrier 90% Gas Furnace: Checked tstat and air filter. Checked blower motor amp draw. Checked electrical connections. Inspected evap coil. No CO detected. Burners are clean. Cleaned Flame sensor. Checked amparage on draft motor. All safety switches are on great condition. System is running great at this time. LeftSideOfHouse Trane HP Pak Unit: Checked tstst and air filter. Checked heat strips and made sure they were on. Checked blower motor amp draws and run cap. Inspected evap coil. Checked compressor and cfm amp draws. Checked dual cap. Checked all wiring at the condenser. Checked pressures. Tested defrost board. Cleaned condenser coil. System is running great st this time.


Manuel M.

Manuel M. Job Checkin

Incomplete 2 Systems worked kn DS Trane Pak System: HO stated system was not cooling. Found system evap coil frozen. Will need to reschedule to come back when system is thawed.


Manuel M.

Manuel M. Job Checkin

Complete 1 System Amana 80% Gas Furnace: EPA Heating Maintenance: cycled system. Checked tstat and air filter. Checked electrical connections. Checked blower motor amp draws. Checked run cap. Inspected evap coil. No CO detected. Burners are clean. Cleaned Flame sensor. Checked amparage on draft motor. All safety switches are on great condition. Checked draft motor. System is running great at this time.


Manuel M.

Manuel M. Job Checkin

Complete 1 System Amana 90% Gas Furnace: EPA Heating Maintenance: cycled system. Checked tstat and air filter. Checked electrical connections. Checked blower motor amp draws. Inspected evap coil. No CO detected. Burners are clean. Cleaned Flame sensor. Checked amparage on draft motor. All safety switches are on great condition. Checked draft motor. System is running great at this time.


Tony M.

Tony M. Job Checkin

Goodman replaced suction valve


Carl T.

Carl T. Job Checkin

Carrier mini split checked system found E1 code due to bad contral board need ro replace contral board


Manuel M.

Manuel M. Job Checkin

Complete 1 System Trane HP Split System: Replace condensate pump. Made sure clear line was clear. System is running properly at this time.


Manuel M.

Manuel M. Job Checkin

Incomplete 1 System Trane HP Split System. Came back to troubleshoot system. Found system low in ref. Added 2 lbs of 410A. And a leak seal. Pressures are great. Found bad condensate pump. Coudnt replace it due to not having one in truck stock. Used the one i had on call before this one. Will need to replace condensate pump.


Manuel M.

Manuel M. Job Checkin

Incomplete 2 Systems worked on US Trane AH with a Goodman HP Condensing Unit. HO stated system was not working. While Tanner went to turn tstat and check air filter I connected Gauges to outdoor unit, found system completly low in ref. Tanner found blower motor not coming. Found bad run cap. Used a 5 uf from truck stock. Still motor didnt come on. Checked and made sure Motor was getting the 240V. Motor needs to be replaced. Need to order the OEM motor, since motor has a special plug for wire connection. I performed a leak search on the system. Had add a few onecs of R22 and nitrogen. Found the leak at the evap. Coil. Couldnt get parts info due to being after hrs.(after 5). Parts need to be ordered from d&L. 2 people 3 hrs. System holds 10 lbs of R22. HO is interested in knowing his options towards a new system. Sending all information to Beth. Air Handler is horizontal is located in the Attic. Easily accessible with left to right air flow. Duct work is in good condition. All Pics in


Manuel M.

Manuel M. Job Checkin

Complete 2 Systems worked on DS Goodman Straight A/C: HO stated he had another company over the weekend. And tehe told him lower unit was completly out on ref. Connected hoses and didnt have any ref. Performed a leak search. Added a fee onces of 410a and notrogen, up to 400 psi. Coudnt find any leak. Opened service ports and found the closed. Release all notrogen from system. Released ref from condenser. Turned on system and pressures are great. System is running properly.