7001 Lark Lane
Sanford, NC 27332
(919) 777-1777

Our Top Cities


Local Reviews
for sanford, nc

Rated 4.9 out of 5 stars based on 115 customer reviews

Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Friendly and knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

I have an older construction grade A/C unit and they have been able to take care of it and prolong its life for me. Always curteous and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

HVAC Replacement

Renee was great at providing options and at explaining the details of the replacement. I feel Renee really cares about the Customer which was displayed in how she presented the facts and benefits of the replacement system.

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

EVERY THING WAS SUPER COULD NOT HAVE BEEN BETTER . SHE WAS SUPER. THANKS FOR ALL THE HARD WORK. THOMAS HAHN

  • Overall Experience
  • Quality
  • Price
  • Convenience

Billy is da Bomb!!

What an ambassador of your company! Just the latest in a long line of great technicians from Comfort First

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

The installers polite and very experienced would recommend them to my friends.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very attentive

Would recommend Renee to our friends.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sanford, nc

Tony M.

Tony M. Job Checkin

Trane ac....no issues


Benjamin R.

Benjamin R. Job Checkin

Complete one system, Airease heat pump. Found bad dual capacitor and replaced it. System is operating properly at this time.


Benjamin R.

Benjamin R. Job Checkin

Working on a Goodman heat pump


Bradley M.

Bradley M. Job Checkin

Completed two systems, worked on upstairs unit. Found bad 45/5 capacitor and replaced it. System is operating properly at this time.


Bradley M.

Bradley M. Job Checkin

Complete: 2 systems worked on US Unit: HO said the US Condenser wasn’t spinning. AT the HP found bad 45/5 cap. Replaced it checked charge and system is working great at this time.


Tony M.

Tony M. Job Checkin

Westinghouse frozen coils


Dennis T.

Dennis T. Job Checkin

Complete one system whole house two zones Goodman split heat pump. Cycled system, cleared drain lines, checked amps caps, charge zone system. System operating properly at this time.


Bradley M.

Bradley M. Job Checkin

Complete: Goodman Package Unit: HO said just stopped blowing cold air. At the unit found no refrigerant. Offered leak search and found leak in liquid line where wires had burnt up again it. the customer was good with search and repair. Patched leak, pulled vacuum and taped wires. The data plate had worn and I did not know how much refrigerant. Weighed in 8lbs. SC was 10 and SH was 25. It’s 89° in his house. Told him once the house cooled we may need to adjust charge some but rt now doing what it should.


Tony M.

Tony M. Job Checkin

Rheem ...no ac


Tony M.

Tony M. Job Checkin

Goodman replaced drain pan


Tony M.

Tony M. Job Checkin

Goodman hp...not cooling


Bradley M.

Bradley M. Job Checkin

Complete: Amana Split HP: HO said system was making a loud banging noise last night and it’s happened before but never replicates while technician is here. Checked system thoroughly. Amp draws, pressures, start up amps, pumped system down, capacitor, cycled system. I saw and found nothing mechanically wrong. When I turned unit off the compressor did make a rattling noise like an engine turning off. She said it was that noise but much louder. She asked about replacing the compressor. I spoke with her about one more potential remedy so I added a hard start to the system. If this doesn’t work we may need to look at changing the compressor. The fan balance was normal. System working great at this time.


Bradley M.

Bradley M. Job Checkin

Complete: 1System Rheem split HP for both floors. Tstat in Bottom floor. HO said it didn’t seem to be cooling properly. At the condenser found coils stopped up as well as both filters inside clogged. Cleaned coils and pulled filters. Checked charge. The system is older but everything is working as it should, just a big load on the older system.


Bradley M.

Bradley M. Job Checkin

Incomplete: 2 Systems worked on US Goodman Split HP: Spoke with HO and she said the system just stopped cooling. At the HP found low side pressure extremely low. Had to add a service valve extension port due to cross threaded service valve. Pressures were low on the high side as well. Performed nitro leak search. Found leak on the suction line valve at the HP. We need to order both service valves from East Coast. Parts Ordered


Tony M.

Tony M. Job Checkin

Epa...