41638 Eastman Dr. Suite B
Murrieta, CA 92562
(888) 659-2665

Local Reviews
for encinitas, ca

Rated 5.0 out of 5 stars based on 2 customer reviews

Great

Great! Promote him and double his pay

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Trevor was extremely helpful in fixing the condenser drainage pipe on our AC unit. He fixed quickly and now we no longer have any water pooling near our house. Trevor also replaced our filter, cleaned out our condenser coils, and outside unit. He was very thorough and took the time to answer all of our questions. Excellent service and we are very happy with his work!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for encinitas, ca

Jorge C.

Jorge C. Job Checkin

Performed diagnostic. Tenant states that system is making a weird noise. Tenant was not on site and was not able to get a hold of him via phone, unsure what noise he was hearing. Checked system thoroughly and started unit up various amounts of times. Unit started up normally every single time. No weird noises coming from the unit. System amp draws are within range and temperature split is cooling correctly. Replaced filter with customer supplied filter. Let property manager know everything is in working order. System is operational upon departure.


Jimmy P.

Jimmy P. Job Checkin

Performed AC diagnostic on two year old Goodman system. Upon my diagnostic client stated that system is not able to drop temperature throughout the day and was able to get to 67° in the past and now it doesn’t get below 75. Found at the outdoor condensing unit to do a secondary motor control has become Defective on the hermetic side terminal which means the compressor wasn’t on. Installed new duel secondary motor control system is cooling with a 15° split differentials and refrigerant pressures look good at this moment. Part was covered under warranty and upon departure system is fully operational and cooling.


Daniel T.

Daniel T. Job Checkin

Performed AC maintenance on a Armstrong air condenser. Systems cooling split is 20 degrees. Condensate lines are clear. Indoor blower is amping ok and spinning freely. Outdoor unit was chemically cleaned. Coil fins have a a good amount of corrosion due to the salt in the air. Copper line set have also been effected with corrosion. Refrigerant levels are ok. Compressor and fan amps are ok at this time. Corrosion inhibitors were installed at this location and his house down the street as well.


Daniel T.

Daniel T. Job Checkin

Performed AC maintenance on a Comfort Pro condenser. Cooling temperature split is 21 degrees. Indoor blower motor is amping in range. Condensate lines are clear. Outdoor unit was chemically cleaned. There is slight corrosion on the copper refrigerant lines due to the salt in the air. I am recommending adding a corrosion inhibitors to halt any further corrosion. Compressor and fan amps are in range at this time. Refrigerant levels are low.


Luis M.

Luis M. Job Checkin

Upon arrival performed maintenance on Lennox unit. Opened up entire system and washed out coils. Took all debree out of unit. Verified refrigerant levels I’m range . Primary and secondary motor control in range . Condenser fan motor good. Electrical fuses in range. Recommended adding surge protectors to keep system protected. Dusted off all electrical components. Merv 16 filter in range. Locking caps for refrigerant on system. Circuit board and electrical connections good. Ducting and attic insulation good. System was reset tested and fully functional upon departure.


Nathan G.

Nathan G. Job Checkin

Paying by Credit Card


Jimmy P.

Jimmy P. Job Checkin

Installed flame sensor and surge protection


Jimmy P.

Jimmy P. Job Checkin

Installed surge protection


Jimmy P.

Jimmy P. Job Checkin

Performed furnace maintenance on 2012 payne Heater. Upon my maintenance I came across a few points and concerns that need to be addressed with the homeowner. Furnace- 1. Found that flame sensor is heavily oxidizing corroded. If left in this condition can lead to failure on ignition due to the inability of the sensor being able to detect flames coming off of the burners 2. System contained no surge protection in the case of a power outage thunderstorm etc. Search protection is added into increase the longevity of all the components in the system most importantly the circuit board which is the brains of the system. 3. Indoor blower motor is Oxidized as well although still operating properly 4. Inducer draft motor is creating a loud screeching noise when running this may also be due to oxidization on the bearing salt water in the air is one of the worst enemies for a motor and can cause an array of problems. 5. Inspected he change room and found small heat spots along with corrosion Call


Jimmy P.

Jimmy P. Job Checkin

Performed furnace maintenance on 2017 comfort Pro heater.


Michael P.

Michael P. Job Checkin

Inspected furnace for faults. Shortened flue pipe and checked all drain ports and hoses. Cleared furnace trap. Diagnosed defective inducer motor. Ordered motor from Goodman supply. Disconnect W1 wire from circuit board so the inducer doesn’t overheat on a call for heat.


Michael P.

Michael P. Job Checkin

Inspected furnace for faults. Shortened flue pipe and checked all drain ports and hoses. Cleared furnace trap. Diagnosed defective inducer motor. Ordered motor from Goodman supply. Disconnect W1 wire from circuit board so the inducer doesn’t overheat on a call for heat.


Michael P.

Michael P. Job Checkin

Added damper system to the upstairs ducting and closed the dampers to allow more airflow downstairs. Shortened the ducting to these runs and removed unnecessary slack. Removed the flat plate on the furnace and added return plenum. Sealed return.


Michael P.

Michael P. Job Checkin

Tested system on the cooling mode and measured temperature splits. Replaced merv8 filter. Tested outdoor motors and recorded voltages. Tested run components and starter. Tightened electrical fittings. Tested the heat and removed excess condensation from the flue which was keeping the burners from igniting. Inspected the ducting.


Jimmy G.

Jimmy G. Job Checkin

Arrived on site to perform main on a unknown age system. Upon arrival spoke over with client and she stated she just moved in and wanted system inspected. She stated another company came out as was unable to service system due to the type of system and no access to work on system. Inspected and house only has heater and no Ac. Over all found system is a hydronic heater and we would not be able to not service this type of system due to the type and no access in attic for air handler. Client cycled heating and system was operational. Client is aware no work was performed just was able to educate client with the type of system it is. Client is aware why were unable to service this system. System is operational upon departure.