Job Checkin

- Arrived on site. - Spoke to the Sierra about what the inspection would include. - Tested incoming water pressure and temperature. - Tested hot water temperature at all of the fixtures inside, checked for leaks, and anything not up to code. - I noticed the hot water heater was not up to code. It was missing an expansion tank and earthquake straps. - I noticed that the toilet angle stop was a multi-turn stop. This type of emergency stop is prone to leaking and failure over time. - I provided Sierra with an estimate to bring their hot water heater up to code as well as an estimate to replace the multi-turn angle stop with a quarter turn one. Thank you for choosing CPI Plumbing and Heating!