Job Checkin

Customer called in because home inspector noted that there was a small amount of water at base of toilet. Shut water off to toilet. Drained tank and bowl. Removed existing toilet supply. Removed existing china caps. Removed existing closet bolts. Pulled toilet. Removed existing wax sink. Installed new closet bolts. Installed new wax ring. Reset toilet. Installed new water supply. Installed new china caps. Flushed toilet 15 times. No signs of leaks found at this time. Applied clear caulking to base of toilet. Customer also stated, inspection noted that water to home was sitting at approximately 105 psi. Gave option to install a new PRV along with a thermal expansion tank in system. Customer declined repairs at this time. Thank you for choosing CPI plumbing and heating!