Arrived onsite, customer had exposed water main outside of foundation and around water meter. Connected 1inch pex to underground polyethylene water main and connected to house water piping inside crawlspace, running pex under foundation. Added 1 inch ball valve main shut off to pex main. Ran PVC line off polyethylene water main to supply shop. On other side of street, connected polyethylene main to water meter. Could not test because water purveyors side of water meter started leaking after connection was made. Because we could not turn the water on or test, informed Jim to call the office if any leaks are noticed in the work we performed.