3129 Swetzer Rd. # G
Loomis, CA 95650
916-577-5020

Local Reviews
for cameron park, ca

Rated 4.8 out of 5 stars based on 6 customer reviews

Great

Awsome great job very professional thanks

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Great! Explained everything and easy to talk to. Really nice guy

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt Service

Got it fixed

  • Overall Experience
  • Quality
  • Price
  • Convenience

Incredible

I have to depend on vendors in the Cameron Park area because of a rental house I own there. I live in Santa Cruz and it is difficult to find businesses I can trust. This has been an amazing experience and once the repairs need to be done, I will definitely contact you again!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Ryan is bad ass.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for cameron park, ca

Jeremy F.

Jeremy F. Job Checkin

Customer has a broken pop-up assembly, someone installed a plastic one for them years ago and its broken now. Removed the old assembly and installed a metal delta pop-up assembly. Filled the sink up and let it drain with no leaks.


Taylor I.

Taylor I. Job Checkin

Technician Taylor arrived on scene to investigate reports of pipe leaking. Take discovered home to be a modular home with the quest plastic pipe leaking under the hall bathroom sink. Technician recommended spot repair of line. Technician noted that the leak has been ongoing for quite some time the carpet on the other side of the wall in the master closet is very saturated, with mold producing. Technician went to acquire parts at supply house. Technician returned with proper parts and repaired line. When technician was testing repair he noted another failure and a fitting a couple feet away. Technician went out again to go purchase more parts to fix new problem. Technician returned and installed new parts. When technician tested again he discovered another fitting tying into the sink had failed. Technician explained to client that piping is of bad quality and age and is destined to continue to fail the more you mess with it. Technician explained that they could return to fix the rest of


Scott P.

Scott P. Job Checkin

Performed annual heating maintenance x2, split Goodman systems Downstairs system in master bedroom closet. WiFi thermostats. 14-25-1 filter. Cycled unit on. System turned on, cleaned off attic platform. Some staining on wood, keep an eye on it. Tested system parts. Hot surface ignitor 65ohms, blower capacitor 12.5@11.3. Primary control board ok. Unit has been converted to lp. Cleaned burners and flame sensor. All style coil/plenum. Black ducts taped not sealed. Some inefficiencies, due to age and shape of system as well as setup. System is working for now. Upstairs furnace WiFi thermostat, tested system. System operational. Found seal between furnace and all style coil broken. Pushed the furnace and coil as close together as possible trying to stop leakage. Found rattling noise from return side of blower compartment needs to be properly sealed. Blower capacitor 12.5@12.6, hot surface ignitor 41ohms. Control board ok for now. Unit has been converted to lp. Both units are getting up


Taylor I.

Taylor I. Job Checkin

Technician Taylor arrived on scene to investigate reports of toilet not flushing properly. Technician discovered The rubber hose running to the fill valve was too long and had fallen off. Additionally the chain for the flush valve was the wrong length. Technician replaced fill valve hose with the appropriate length part. Technician also adjusted chain to aid with flush. Technician inspected clients insta hot heater underneath bathroom sink per client request. Technician diagnosed and believes the unit to be burnt out. Technician quoted client $690 for replacement. Client did not want to perform work today.


Scott P.

Scott P. Job Checkin

Performed annual heating maintenance 20 yr split Goodman upflow system , upstairs closet. System is operational at this time. Not in the best shape. Has had some repairs done in the past. Newer hot surface ignitor. Cleaned up burners and flame sensors. Filter has just been changed. 16-25-1. Blower motor appears to have been replaced as well. Blower wheel starting to get dust on it. Furnace runs on LP. Gas line into system doesn’t have a drip leg, not to code. Burner compartment has burn mark in it, not sure where they came from. Burning well at this time. Checked seals on unit to plenum, tape is starting to separate in back left corner but doesn’t seem to be leaking air yet, we can keep an eye on it. Unit rattles a little bit, we will keep an eye on it. Electrical board looks ok, no burn marks or burnt wires at this time. System is operational at this time. Due to age and efficiency of system recommend looking into replacement options before failure.


Grayson  C.

Grayson C. Job Checkin

- Disconnect water supply to existing unit to drain - Drain and remove unit (disposal included) - Modify water supply to accommodate dimensions of new water - Reuse existing water supply shut off valves - Disconnect existing water heater electrical label breaker if needed - Reuse existing water heater timer - Expansion tank provided and installed - Start up and temperature fine tuning included - Permits, Licensing, Insurance, and Inspection Coordination Included -costumer reference number for American shield is 545978972kvp -claim number given by American shield is 130kbbm.


Samuel T.

Samuel T. Job Checkin

Discussed options for installing new heater Collected down payment


Chris R.

Chris R. Job Checkin

We will drain the water down to the house. We will remove prv and install a new prv with the new fittings that are needed up to the point where the water line enters the house. We will check for leaks and assure everything is functioning as it should. Installed new prv valve and rebuilt assembly going into the main.


Scott P.

Scott P. Job Checkin

Customer would like follow up call at some point between 2/14 and 2/21 to allot time for other schedule projects


Brandon B.

Brandon B. Job Checkin

No charge to customer for service today, call back on previous work .water supply line leaking from hot water side. Tightened nut and tested for leaks. Stood for ten minutes to verify no leak or drip. No more leaks.


Brandon B.

Brandon B. Job Checkin

No charge to customer for service today, call back on previous work .water supply line leaking from hot water side. Tightened nut and tested for leaks. Stood for ten minutes to verify no leak or drip. No more leaks.


Brandon B.

Brandon B. Job Checkin

No charge to customer for service today, call back on previous work .water supply line leaking from hot water side. Tightened nut and tested for leaks. Stood for ten minutes to verify no leak or drip. No more leaks.


Brandon B.

Brandon B. Job Checkin

Hall bath toilet keeps running, need to replace fill valve. Need to shut water off and replace old fill valve with new fluidmaster 400a fill valve and adjust water level to proper height. Turn water back on and rest for operation. After installing new fill valve, tested toilet for operation. New fill valve is working properly and toilet flush is good and strong. No concerns with toilet at this time. Shut off valve for same toilet had small leak coming from stem when in the off position, tightened packing and tested for leaks. Turned knob to off and on position multiple times, no more leak. Spoke with customer about becoming a member, customer is going to speak with her husband before making a decision.


Brandon B.

Brandon B. Job Checkin

Hall bath toilet keeps running, need to replace fill valve. Need to shut water off and replace old fill valve with new fluidmaster 400a fill valve and adjust water level to proper height. Turn water back on and rest for operation. After installing new fill valve, tested toilet for operation. New fill valve is working properly and toilet flush is good and strong. No concerns with toilet at this time. Shut off valve for same toilet had small leak coming from stem when in the off position, tightened packing and tested for leaks. Turned knob to off and on position multiple times, no more leak. Spoke with customer about becoming a member, customer is going to speak with her husband before making a decision.


Brandon B.

Brandon B. Job Checkin

Hall bath toilet keeps running, need to replace fill valve. Need to shut water off and replace old fill valve with new fluidmaster 400a fill valve and adjust water level to proper height. Turn water back on and rest for operation. After installing new fill valve, tested toilet for operation. New fill valve is working properly and toilet flush is good and strong. No concerns with toilet at this time. Shut off valve for same toilet had small leak coming from stem when in the off position, tightened packing and tested for leaks. Turned knob to off and on position multiple times, no more leak. Spoke with customer about becoming a member, customer is going to speak with her husband before making a decision.