Brandon B.

Brandon B. Job Checkin

Install new fill valve Customer stated that she is on a tight income and only wanted to do minimum repairs. Toilet does not phantom flush so only fill valve needed to be replaced. Installed new fluidmaster 400 a fill valve and tested for operation. Toilet is working fine.


Brandon B.

Brandon B. Job Checkin

Install new shower faucet valve stems to stop leak Installed hot and cold valves model number 3s-9h/c in glacier bay two handle faucet to stop leak on cold side. Turned water back on to test for leaks, no more leak.


Brandon B.

Brandon B. Job Checkin

Extend hose bib from below back deck to top of deck Cut 3/4 “ copper water line in basement and added a 3/4” x1/2” t and extended 1/2 copper line to upper deck area. Installed wall bib on upper deck and sealed to wall. Turned water supply back on to test for leaks, no leaks at this time.


Brandon B.

Brandon B. Job Checkin

Install customer supplied delta single handle kitchen sink faucet and three hole covers to plug unused holes. Delta faucet model number 9181t-rb-dst brushed nickel finish. Installed and rested for leaks.


Brandon B.

Brandon B. Job Checkin

Repair 1” pvc water line with new valve and fittings Cut out 1” pvc pipe and fittings to replace ball valve and cracked pvc 90. Replaced with copper 90 , pvc ball valve and copper union. Tested for leaks, no more leaks. System under pressure. A,so discussed Crystal Blue membership with customer, customer is going to discuss with wife before making a decision.


Brandon B.

Brandon B. Job Checkin

Rebuild master bathroom water closet Customer stated that the toilet would partially fill a few times in the end toilet for a couple of minutes to see if water marks were visible inside the lower tank, none were visible. Water is somehow flowing to lower bowl with out leaving evidence. Replaced flapper and fill valve, adjusted water level to manufacturer recommendation.


Brandon B.

Brandon B. Job Checkin

Water main leaking at union coupling to pressure reducing valve. Union is cracked and needs to be replaced. Customer stated that price was too high and is going to try to fix himself. Quote is flat rate parts and labor. Quote is good for three months.


Brandon B.

Brandon B. Job Checkin

Quote for repairs only, home is in process of being sold and customer needs to get approval from potential buyers before work can be performed. Customer will call back once approved and will contact office to schedule an appointment.


Brandon B.

Brandon B. Job Checkin

Removed p-trap assembly under kitchen sink to unclog. Kitchen sink dual basin sink only clogged on garbage disposal side. Removed lots of food debris. Gave customer advice on how to properly use garbage disposal and recommended chemical maintenance. Talked to customer about Crystal Blue membership, unit is going to pass information on to home owner.


Brandon B.

Brandon B. Job Checkin

Upstairs guest bathroom toilet clogged. Filled toilet to rim and ran water at other fixtures to determine how far clog was from toilet. Blockage is in toilet, ran auger through toilet to unclog. Unknown blockage, did not pull back any debris. Also spoke with customer about Crystal Blue membership. Customer is going on trip and will call office to pay for membership.


Brandon B.

Brandon B. Job Checkin

Customer called and stated that they had a water line leak outside of home. Upon arrival I met with home owner Jerry to give quote for repairs. Customer stated that he already had another quote but was shopping for best price. Quoted customer for repair, then contacted local water district to shut water off to make repairs. After exposing water line, found a 1 inch pvc 90 that had a crack in it causing leak. Technician cut out about two feet of 1 inch pvc water pipe, 90, and male adaptor and replaced with 1 inch copper pipe, 90, male adaptor, and union. Let glue joint cure for 30 minutes before leak testing, no leaks.


Scott P.

Scott P. Job Checkin

Performed annual ac maintenance Cameron Park. 14 yr old Goodman split system upstairs closet back yard. Filter 16-25-1 ok shape. Washed condenser coils, back side of unit pretty dirty. Checked electrical connections all tight at this time. Contactor looks good. Disconnect looks good. Low voltage to unit not in whip. Refrigerant r22 ok. Removed wasp nest from electrical panel. Dual capacitor 55-5 in range. Re attached insulation to suction refrigeration line. Temperature split for ac is 18 degrees. Emailed options on repairs


Scott P.

Scott P. Job Checkin

Performed annual maintenance on two 19 yr split Goodman systems. Downstairs and upstairs. Tested all parts. Contactor looks good, checked disconnect and wire connections all tight at this time. Dual capacitor 35-5 ok. Refrigerant levels for downstairs unit just above freezing. For upstairs unit in bad shape, see pictures. Line sets insulated. Upstairs unit outdoor fan making noise, and pulling high amps. Upstairs unit electrical panel not attached fully. Downstairs unit disconnect not shut fully. Washed both condensers. Black fed ducts taped not sealed. Due to age of system, would recommend repair vs replace options. Added refrigerant, r22, to system to get system above freezing point and correctly cooling.


Scott P.

Scott P. Job Checkin

Performed annual maintenance on two 19 yr split Goodman systems. Downstairs and upstairs. Tested all parts. Contactor looks good, checked disconnect and wire connections all tight at this time. Dual capacitor 35-5 ok. Refrigerant levels for downstairs unit just above freezing. For upstairs unit in bad shape, see pictures. Line sets insulated. Upstairs unit outdoor fan making noise, and pulling high amps. Upstairs unit electrical panel not attached fully. Downstairs unit disconnect not shut fully. Washed both condensers. Black fed ducts taped not sealed. Due to age of system, would recommend repair vs replace options. Added refrigerant, r22, to system to get system above freezing point and correctly cooling.


Ryan  M.

Ryan M. Job Checkin

Leaking out of sch 80 ball valve union, replaced with new sch 40 ball valve and sch 80 ballvalve