520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.


Local Reviews
for brookhaven, pa

Rated 4.7 out of 5 stars based on 3 customer reviews

Good company, reasonable pricing

Chris is very efficient and knowledgeable..booties are used which I really appreciate...

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, friendly technician

Good feeling about the company... they seem honest and reputable....

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great service, very reasonable, helpful and friendly service technician.. very happy with this company.. will call again...

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for brookhaven, pa

Joseph D.

Joseph D. Job Checkin

Reviewed home to look at home performance and converting from oil boiler to gas furnace and ac and heat pump systems.


Joseph D.

Joseph D. Job Checkin

Talked to Nick about the issues with the home. They just moved in 2 months ago and always feel cold, always hear the oil furnace coming on and off. Inspected home from basement to kneewall spaces to identify potential opporturtunities to increase comfort and efficiency. Will provide estimate for upgrades to insulation and and air sealing.


Bill D.

Bill D. Job Checkin

.


Bill D.

Bill D. Job Checkin

Customer was just looking for information. He’s going to replace his chimney vented, gas water heater by himself.


Tony F.

Tony F. Job Checkin

Estimate


Shawn R.

Shawn R. Job Checkin

Arrived to do Maintenance on two systems, one attic one basement. Attic: Checked thermostat for operation, checked and changed filter, primed and cleaned EZ trap, checked blower motor amp draw and capacitor, tightened all electrical connections, checked temperature split. Went outside and checked compressor amp draw, condenser fan motor amp draw, checked dual capacitor and refrigerant pressures. System is working correctly at this time. First floor: Checked thermostat for operation, checked and changed filter, primed and cleaned EZ trap, checked blower motor amp draw and capacitor, tightened all electrical connections, checked temperature split. Went outside and checked compressor amp draw, condenser fan motor amp draw, checked dual capacitor and refrigerant pressures. System is working correctly at this time. Also wired in customer supplied thermostat.


Luis T.

Luis T. Job Checkin

Performed ac tune up, check electrical low and high voltage connections replaced filter, flushed drain test pump check airflow ok, check outdoor unit refrigerant capacitor and contactor, found burnt wires, and pitted contactor, provided an estimate for repairs and replacement of parts, customer decided to replaced, contactor, capacitor and hard start kit. Replacement of capacitor, contactor and hard star assist cycle unit ok


Luis T.

Luis T. Job Checkin

Performed ac tune up, check electrical low and high voltage connections, check blower motor and cap ok, flushed drain, was partially clogged, test safety’s wet switch and float switch ok, check supply and return air, replaced air filter 18x30x1 and told customer to replace filter every 90 days, check outdoor unit trough the wall type condenser, capacitor and contactor ok refrigerant pressures r22 within specifications, noticed blower wheel was dirty and recommended installation of ez trap with float safety, provided an estimate and customer approved repairs, performed repairs during same visit, Removed Blower wheel and cleaned wheel and housing also installed ez trap and wired float switch in series with other safety’s test ez trap and flushed trap ok cycle unit ok.


Brian B.

Brian B. Job Checkin

Performed heating maintenance, checked air filter ok. Cleaned burners and flame sensor, inspected heat exchanger. Blew out condensate trap and drain. Checked voltage, amperage and electrical connections, measured capacitor values. Started gas furnace, tested limit and safety switches. Measured fuel pressures and performed combustion test.


Brian B.

Brian B. Job Checkin

Performed heating maintenance, replaced air filter. Blew out condensate trap and drain. Cleaned burners and flame sensor, inspected heat exchanger. Checked voltage, amperage and electrical connections, measured capacitor values. Started gas furnace, tested limit and safety switches. Performed combustion test. Checked operation and temperature rise.


Barry P.

Barry P. Job Checkin

Changed filter.


Chris B.

Chris B. Job Checkin

Performed Precision AC Tune Up on system. Checked 18x30x1 Air Filter. Filter is starting to get dirty and should be replaced before the summer season. Did not have that size filter on the truck. Need to schedule a time to come back to replace the Air Filter. Checked electrical components on System and found the Capacitor for the Condenser Fan Motor was leaking oil and Epps’s testing below rating. Replaced Capacitor and tested. Cleaned drain Line for Air Conditioner. Put system in operation and measured refrigerant charge and Air Temperatures. Homeowner stated that the new Water Heater is running out of hot water when she takes a shower after about ten minutes, which is how the old water heater ran also. Checked both thermostats on the water heater which were set to Hot. Ran hot water at the kitchen faucet which was reading between 116 Degrees and 124 Degrees. Measured Amp Draw on Heating Elements at 17.8 Amps. The water heater is operating normally at this time. Homeowner is going


Luis T.

Luis T. Job Checkin

Disconnected existing furnace to remove 40 gal electric water heater. Disconnected high and low voltage, condensate and flue piping. Removed furnace and moved out of way. Drained and disconnected existing water heater. Installed new 40 gal electric water heater. Filled and purged system. Reinstalled existing furnace and completed all connections. Reinstalled high and low voltage, condensate and flue piping. Tested water heater, furnace and air condition. Also installed new battery’s in thermostats per customer request. Furnace and air conditioner working as they should. Water heater temp is adjusted to customers liking.


Brian B.

Brian B. Job Checkin

Performed cooling maintenance, checked air filter ok. Cleaned eztrap and drain. Checked voltage, amperage and electrical connections, measured capacitor values, found burnt wire on run capacitor, repaired wire. Started air conditioner, checked refrigerant charge and temperature drop across coil.


Luis T.

Luis T. Job Checkin

Replace inducer under parts warranty, after installation of new inducer check furnace operation ok performed combustion test ok cycle furnace,