Great job on the follow up needs for my hvac. Thanks.
Brandon did excellent work today. Really appreciate the commitment, communications and clarity on the scheduled work. Thanks.
Brandon did an awesome job today. Routine maintenance completed and found an issue with electrical components that would have been an unplanned event. We scheduled the work and appreciate the great service.
Jared was great! Very respectful of my home, competent and personable.
Outstanding service and response to my heater issue and just want to say Thank You!!
Keith is great! Dobbs is fantastic; I’ve been with Dobbs since buying my house in 2012. And I’ll continue to be a Dobbs customer.
As usual, Dobbs’ service was awesome! Gary the tech was great! Knowledgeable and a great guy!
Removed faulty condenser variable speed motor, opened new motor and it is an indoor variable speed motor, will not work. Explained to home owner and informed office. Sent pictures of correct motor. Office needs to call customer.
Removed old equipment and installed new Rheem 3 ton heat pump, 3 ton evaporator coil with 80% gas furnace. Installed new return plenum with 16x25x4 filter, new emergency drain pan, new pan safety switch, new coil safety switch, new thermostat, new composite pad, and new line voltage monitor for outdoor unit. Reconnected supply plenum, high voltage, low voltage, drain line, gas line, vent pipe and return drop box. Tested system operations in heating and cooling, set refrigerant charge.
Completed single system cooling maintenance, replaced filters system operating properly at this time. The system is very old R22, talked with owner about replacing unit.
2020 Rheem Heat Pump has bad variable speed outdoor condenser motor. Needs replaced. Need to check warranty and give quote.
Completed cooling maintenance on 12 systems. Unit #4 has a bad contactor and a burnt wire. Unit is very old R22. Pictures of capacitor and wiring included. All other systems are operating as well as they can. All units are very old R22. They all need to be updated. All filters replaced.
Quoted in hvacbizpro and emailed over
Put strap on hard start
Today i installed kickstart to club member Trane unit. I explained and showed Mr and Mrs Smith the kickstart and will return to install bracket to hold kick start. Everything is operating properly
Completed single system cooling maintenance, checked filter and left one. System operating properly at this time
Returned to install kick start.
Today I clean the evaporator coil and blower wheel. I also installed 2 inline voltage surge protectors. Have to schedule to install kick start for one unit. Club members are aware
Finished running 6” duct and installed new thermostat for upstairs unit.
Removed old equipment and installed new Rheem 2 ton 454-b a/c with 2 ton evaporator coil and 80% gas furnace. Installed new supply plenum, new return plenum with 16x25x4 media filter, new coil safety switch, new pan safety switch, new thermostat and new composite pad for outdoor unit. Extended and reconnected high voltage, low voltage, drain line, gas line, vent pipe and all ductwork. Tested system operations in heating and cooling, set refrigerant charge. Will need to return with 6” flex to extend last duct. Also another thermostat for upstairs unit
Completed 2 systems cooling maintenance, checked filters, both operating properly at this time
For this job I discovered an arch kickstart inside the condenser unit. I explained to club members they should check into inline surge protection.I also check upstairs unit and found the blower wheel needs to be cleaned along with evaporator coil. Customer provided filters and wants to set up date for inline surge protection and blower wheel cleaning with evaporator coil cleaning.