A.c. tune up performed at residence near will rogers airport found that capacitor was reading proper microfarad but homeowner client wanted to look at options for air purifier uv light attached to central hvac system
Finding that tankless gas water heater has sensor relay switch that is not functioning properly replacing heat sensor on tankless gas furnace repair service and doing tank contamination service to flush and clean tankless water heater
Doing gas furnace tune-up on Lennox residential upflow 80% afue rating gas furnace in attic of home. Checked flu pressure switch for inducer motor as well as amp draw on inducer motor as well as blower motor amp draw readings to ensure run load amperage is correct within parameters of manufacturer specifications also checking run capacitor for proper capacitance readings reading 4.83 microfarads for the 5 microfarad 440 volt run capacitor appears to be working in normal operating condition
Doing plan maintenance on Lennox 3 ton condensing unit air conditioner in Johnson farms neighborhood
Installing pilot assembly that was ordered previous visit on Empire gas fireplace in Johnson farms edition
Empire Comfort Systems gas fireplace repair service call. Fireplace not coming on. Ordering pilot assembly.