850 U.S. 9
Fishkill, NY 12524
845-896-4328

Local Reviews
for carmel hamlet, ny

Rated 4.9 out of 5 stars based on 126 customer reviews

Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service! Noah was knowledgeable, efficient, professional and caring

Noah was knowledgeable, efficient, resourceful, professional and caring!! Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

  • Overall Experience
  • Quality
  • Price
  • Convenience

outstanding service!!

scott was great! he was on time, professional, courteous and VERY helpful being sure to explain everything!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

He was very nice, neat, and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous and friendly

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly, great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Owner of condo ! Great service, ggreat price

Dan did a. Great job and explained our questions very well !!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

We had a fumes issue and a whistling AC issue. Chris diagnosed both problems quickly and fixed them

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for carmel hamlet, ny

Scott Y.

Scott Y. Job Checkin

C/S Gas. Upon arrival found humidifier leaking from bottom of humidifier, found when we replaced pad last spring for customer we did not have bracket holding pad fully secured inside of humidifier, secured pad in correct position allowing the drain hole to align with the drain hose. Tested inducer, gas valve, flame sensor, igniter, pressure switch, blower motor and capacitor. Customer has uv light, electronic filter, and humidifer. Customer had replacement pads, and filters, replaced both humidifer pad and filter. Performed combustion test. Found blower capacitor reading under manufacturer rating, recommend to replace. Could not get a hold of husband regarding capacitor, he was at a meeting for work and wife had to leave house so I could not stay at location. Sent estimate for capacitor to customers email. System is running normally.


Greg M.

Greg M. Job Checkin

Found louver hanging down upon arrival. Not closing properly. Removed covers and adjusted louver for proper opening and closing. Cycled system multiple times and checked temperature differential. 35F differential at this time. Cleaned filters and wiped down system.


Danny B.

Danny B. Job Checkin

No heat due to power switch turned off at top of the stairs, due to no issues with boiler new install visit is charged a diagnostic charge.


Margaret M.

Margaret M. Job Checkin

Completed annual clean and service of one gas fired furnace. Removed and cleaned flame sensor. Examined heat exchanger for any signs of wear and tear and or cracks. Tested all safety switches to ensure proper operation. Replaced one 24x24x1 air filter. Took temp rise. Ensured thermostat was operating correctly. Checked gas pressure. Recommend duct cleaning. No further issues to report at this time of service. Spoke with son upon arrival and he states there is no issues with heating system he just wanted to make sure everything was up to par.


Margaret M.

Margaret M. Job Checkin

Completed annual clean and service of one gas fired furnace. Removed and cleaned flame sensor. Examined heat exchanger for any signs of cracks or rust spots. Adjusted gas pressure from 3.74 to 3.5. Examined and tested all safety switches within system. Recommend duct cleaning. Unable to perform combustion analysis due to not being able to access flue due to the flue exiting the side of apartment building.


Greg M.

Greg M. Job Checkin

Found both indoor units flashing F6 and flashing 7 times and outdoor unit showing F1 fault. Could not get faults to clear. According to manual indoor coil sensor faults, system has two indoor heads. Called tech support left message with no response. Will need to wait on tech support return call for diagnostic.


Margaret M.

Margaret M. Job Checkin

Arrive to customers house to perform annual maintenance, while doing so tested capacitor notices tested I range, replaced capacitor


Margaret M.

Margaret M. Job Checkin

Arrive to customers house to do annual service checked ductwork recommended UV light and duck cleaning, emailed customer Quotes, Will have to return in spring time to check Ac due to cold weather,


Danny B.

Danny B. Job Checkin

Clean and service Gas water heater Navien, humidifier sold for later install, collecting deposit of total amount $1,471.10 of half $735.55, remaining amount upon completion of job $735.55.


Chris H.

Chris H. Job Checkin

Customer would like to reverse the loop if all possible, so main basement heats up quicker took pictures will go over with service manager to explain better to him.


Margaret M.

Margaret M. Job Checkin

Arrive to customers house to find majority of vents closed, open vents and noise stopped change filter for a customer


Zack L.

Zack L. Job Checkin

Folkes arrived on 11/18/2021 to install a new 40 gal water heater. Upon arrival I started by turning the water off and draining the unit. I then cut out the old unit and put the new one in its place. I saw that the floor was messed up and may need to be replaced I recommended to customer and had first response come and take a look. I left estimate to disconnect and reconnect the water heater when customer decides to replace the floor. I then added an expansion tank to the new water heater and connected everything and turned the water back on and checked for leaks. There are no leaks at this time. It may take a few hours for the new water heater to heat up to the proper temperature. I then thanked the customer for choosing folkes and left.


Chris H.

Chris H. Job Checkin

Customer stated loud groaning noise from basement circulator and master bedroom was at 64 degrees last night, we replaced some water components yesterday and found this two zones very air bound, purged all four zones for home and waited until supply and return pipes got hot as well as baseboards, system operational and working and heat properly.


Chris H.

Chris H. Job Checkin

Customer has a oil fired furnace in crawl space, customer had made some repairs to furnace with new burner motor and primary control due to water damage and had also place flex duct tape on chimney flu piping, the smell they are smelling is the foil tape melting, chimney flue just needs screws not masting tape, took combustion test of system which everything is normal, blower came on, had a 45 degree delta t reading, customer did sign up for maintenance agreement for one oil fired furnace system hasn’t been serviced in a few years. System is operational and working. :


Scott Y.

Scott Y. Job Checkin

C/S oil fired boiler replaced filter strainer and nozzle. Brushed and cleaned boiler and exhaust. Performed combustion test. Checked over all components. No issues to report system running normally.