First real tune up since I bought house last year. Tried other company and had horrible service. Grand Canyon rep was professional and thorough. He did not rush and answered all my questions and concerns. Great job!!
Response from Grand Canyon Home Services:
We thank you for sharing your positive experience. It made our day.
Response from Grand Canyon Home Services:
Thank you for your feedback. Our team is very thankful.
Jose was a perfect gentleman. He explained everything in a clear plain, understandable way. Very friendly. Look forward to maybe seeing him in the fall.
Response from Grand Canyon Home Services:
We’re delighted to hear about your recent experience with us and we’re so pleased that you recommend our services. Thank you for taking the time to share your experience and we look forward to welcoming you back soon!
This is a great company. They do outstanding work on time and at a great price.
Response from Grand Canyon Home Services:
Your kind words mean a lot to us. Thanks for leaving such a positive review!
Went out to assist a customer whose water heater was only producing lukewarm water. Found that the issue stemmed from a faulty heating element. After diagnosing the issue I replaced the damaged part and tested the system. The repair restored full functionality, ensuring the household had reliable hot water again.
I was called to repair an emergency air conditioning system. The Bryant ac system was not cooling the house. I diagnosed the problem and replaced the faulty compressor. The customer was thankful for the service.
I was called out to an emergency repair on an air conditioner. I arrived at the customer's house and diagnosed the problem as a broken compressor. I replaced the compressor and the air conditioner was working again. The customer was very happy with the service and thankful for the repair.
Maintenance on an American Standard air conditioner. The system was thoroughly inspected for any signs of wear and tear and ran to check performance. The air filter was found to be dirty and causing poor air circulation. The filter was replaced and the system is now running optimally for the home.
Conducted an emergency repair on a Bryant air conditioner. Diagnosed a faulty compressor capacitor using a multimeter. Replaced the defective capacitor with a Bryant OEM part. Checked refrigerant levels with a manifold gauge set and found them within the required range. Restored the system and verified efficient cooling. Ensured all components were functioning correctly before leaving the site.
Replaced failed compressor on Heil H4A348AKA air conditioning unit. Recovered R-410A refrigerant using Fieldpiece MR45 recovery machine. Removed faulty Copeland ZP31K5E-PFV-830 compressor. Installed new compressor, applying POE oil. Brazed connections with nitrogen purge. Evacuated system to 500 microns with Yellowjacket 93600 vacuum pump. Recharged to factory specifications. Tested amperage draw and superheat/subcooling. Verified proper operation across all stages of cooling.
Replaced the motor on an AC unit. Diagnosed a failed blower motor in a Trane XR14 system. Disconnected the power and removed the old motor. Installed a new OEM blower motor and ensured proper alignment. Reconnected wiring using wire nuts and secured connections. Tested the motor for proper operation. Verified the system’s airflow and cooling performance. Conducted final checks to ensure all components were functioning efficiently before completing the job.
Repaired an old Trane air conditioner. Diagnosed a malfunctioning contactor using a multimeter. Removed the faulty contactor and replaced it with a new Trane OEM part. Inspected the condenser coils and cleaned them with coil cleaner. Verified refrigerant levels using a manifold gauge set and found them within the optimal range. Tested the system to ensure proper cooling performance and efficient operation. Conducted a final inspection to confirm all components were functioning correctly before leaving the site.
Conducted comprehensive maintenance on Trane XL18i air conditioner, model 4TTX8060A1000AA. Cleaned condenser coils using Nu-Calgon Evap Pow'r-C and 1800 PSI pressure washer. Checked refrigerant charge with Testo 557s digital manifold, adjusted to manufacturer specifications. Replaced clogged 20x25x1 MERV 11 air filter. Inspected and tightened electrical connections, measuring voltage drop across contactor. Lubricated condenser fan motor bearings with SAE 20 non-detergent oil. Cleaned condensate drain line with CO2 blast cartridge. Calibrated Trane ComfortLink II thermostat and verified system performance through all operating stages.
Replaced failed compressor in York YCJD48S41S1 AC unit. Recovered R-410A refrigerant. Removed Copeland ZP42K5E-PFV-830 compressor. Installed new compressor, brazed connections under nitrogen purge. Evacuated system to 250 microns. Recharged to 6.2 lbs R-410A. Verified 12°F subcooling and 18°F superheat. Tested amperage draw and capacitor microfarads.
Repaired an air conditioner leaking water. Found a clogged condensate drain line using a wet/dry vacuum. Cleared the blockage and ensured proper drainage. Inspected the evaporator coil and cleaned it with a coil cleaner to prevent future issues. Tested the system to confirm the leak was resolved and verified efficient cooling performance. All components are now functioning correctly.
Performed Freon repair on a Carrier air conditioner. Diagnosed low refrigerant levels using a manifold gauge set and detected a leak in the evaporator coil with an electronic leak detector. Repaired the leak using a silver solder kit. Pulled a vacuum on the system with a Robinair VacuMaster to remove moisture and air. Recharged the system with R-410A refrigerant to the manufacturer's specifications. Conducted a final test to ensure optimal cooling performance and system efficiency.
Repaired a York air conditioning system that needed a new motor. Once the motor was replaced, the system was tested to ensure it was working properly again. The customer was pleased with the service.
Performed a plumbing inspection at a client's home because the kitchen sink was not draining properly. I identified the issue, which was a clogged drainpipe. I then used a specialized tool to remove the clog and ensure that the sink was draining properly again.
Diagnosed a water heater that was not working. Found that a faulty pilot light, which was identified as the source of the problem. We promptly re-lit the pilot light and adjusted the settings to restore efficient heating. We confirmed the water heater was functioning correctly, before departing.