Compressor on amana heat pump was nut running. Found and repaired burnt wire going from contactor to capacitor. Also added surge protection to the unit.
Performed owed maintenance on equipment. Found what appears to be mold growth inside of air handler as well as dirt beginning to build up inside blower wheel. Discussed air purifier to remedy mold problem and to provide cleaner indoor air quality for home. Also discussed comfort club renewal with customer.
Performed owed maintenance. Filter was still in good condition. Found no issues with the equipment at this time. Discussed surge protection and renewal with customer. Customer will call in to renew.
Service Call After Hours Fee R22 14 years old Unit has a bad condenser fan motor. Attached quote for replacement. I am recording to replace air conditioning due to the refrigerant r22 in it and low efficiency and age. 208-230 PH 1 HP 1/4 RPM 850 Customer had a new furnace replaced. They are food to talk about either replaced motor or just replace the whole air conditioning system.
Performed Platinum Comfort Club Membership Tune-Up on Cooling System: checked capacitor, checked contactor. tested defrost operation. cleaned out service panel of bug and cobwebs. checked refrigerant levels. all checks good.
Service Call Fee: no furnace operation, voltage was correct at board, but thermostat was not closing terminals. replaced with AA8444 and tested operation
Yearly Maintenance Check Performed by Travis W.
Removed and replaced capacitor. Installed Aprilaire 8476 Digital Programmable Thermostat w/ Event-Based Air Cleaning. Work performed by John B.
Arrived and found system slightly low on refrigerant, tightened leaking schrader valve on suction line. Charged 1lb of 410a. System is operating properly at this time. Lock out caps would be recommended.
Bad hot surface igniter. Honeywell glow fly replacement.