5349 Dupont Road
Parkersburg, WV 26101
304-863-3553

Local Reviews
for walker, wv

Rated 5.0 out of 5 stars based on 4 customer reviews

Excellent service

We are always very pleased with Frank's service to our geothermal heating system. He is very knowledgeable about the system and our particular furnace set-up.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from Grogg's Heating & Air Conditioning, Inc. (Parkersburg):

Thank you for the great review and your confidence in our services. Please consider us for all your Home Services needs. Don't keep us a secret.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great work

Good work on machine that’s getting old


Response from Grogg's Heating & Air Conditioning, Inc. (Parkersburg):

Thank you for the awesome review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from Grogg's Heating & Air Conditioning, Inc. (Parkersburg):

Thank you for the great review and we hope you use Grogg's in the future for your Home Services needs.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for walker, wv

Travis W.

Travis W. Job Checkin

Yearly Maintenance Check Performed by Travis W.


Travis W.

Travis W. Job Checkin

Yearly Maintenance Check Performed by Travis W.


Fred E.

Fred E. Job Checkin

Arrived and found transformer shorted. Replaced under parts only warranty. May want to think about whole home surge protection and system maintenance.


Fred E.

Fred E. Job Checkin

Arrived and found pressure switch full of water. Cleared all drains. Found PVC shavings and debris clogging glue condensate line. Emptied pressure switch and ran combustion analysis. System is operating properly at this time.


Adam R.

Adam R. Job Checkin

Removed and replaced stat. Tested operation all checks are good..


Fred E.

Fred E. Job Checkin

Repaired flare fittings and connection behind slim duct. Pressure checked with nitrogen. Pulled vacuum and charged system with 4lbs 10oz of 410a.


John B.

John B. Job Checkin

Preformed warranty check


Richard M.

Richard M. Job Checkin

System has leaky connections need to return with help to re connect fittings


Draymond W.

Draymond W. Job Checkin

Install new Heat Pump duct system. All new metal duct, new refrigerant lines, pad, disconnect and whip, electric and drain material.


Richard M.

Richard M. Job Checkin

Checked heating system , ran combustion analyzer system exceeds system spec for efficiency and has no defects in operation at this time. Also cleaned flame sensor.


Richard M.

Richard M. Job Checkin

Replaced hot surface igniter and cleaned flame sensor send paper receipt in mail.


Justin L.

Justin L. Job Checkin

Price for new electric furnace


Adam R.

Adam R. Job Checkin

Arrived to find gas valve leaking through after unit kicks off, under standing pilot using sniffer detected strong leak from burner tubes, I turned unit supply gas valve off and eliminated detection from sniffer. Recommended unit needs new gas valve, truly unit needs replacement as parts and repair will be costly. EST lv 6 399


Frank  M.

Frank M. Job Checkin

Geo


Adam R.

Adam R. Job Checkin

Arrived to find flash code 1- flame present no gas. Good pressure No valve off couldn’t issue get re occurr. Ran through several cycles Performed heating checks all good.