Hector was right on time for our system check-up. He was very thorough in explaining everything he was measuring and testing. Gave us some tips on self maintenance and what we could do to keep system running great. I give him five stars!
Estimate quote for new ductwork
Brennan G Today I visited for the system not cooling. I found the breaker for the condenser was loose inside the main panel. The panel is very old and should be updated, i re connected the breaker and everything is operational. I am not sure if this is initially what caused the system to stop cooling, waived todays dispatch fee.
Today we visited to evaluate the existing air-conditioning system. The unit is not cooling and historically has not done a good job when it is hot outside. We learned the system has a refrigerant leak in the evaporator coil and one of the solder joints near the filter dryer. We also discovered, after performing a heat load, that the existing 2 ton system is undersized and should be a 2.5 ton system. James put together two replacement options for Martin and informally texted them to him.
Perform diagnostic,found T6 smart thermostat not working,installed temporary thermostat,need to return with T6 WiFi smart thermostat. 8-5-22 installed new T6 smart thermostat,system checked good and draining properly.
Perform diagnostic and evaluation of System operation and present Customer with multiple options for Maintenance, Repair, or Replacement of System.upon arrival system operation is normal. Refrigerant levels are good. Checked subcool superheat good. Cleared drain.
Completed Maintenance on system Blower and coils are ok Primary drain line is clear Filter is clean Electrical Components are ok Compressor amp load is normal Temp Differential is 21 degree Pressures are normal System operation is normal at this time