Job Locations
for fairborn, oh

Justin S.

Justin S. Job Checkin

144065


Justin S.

Justin S. Job Checkin

I completed a half install on a Five Star 13 SEER 2.5 ton air conditioner. I cycled and monitored the system. Operating normally at this time.

I completed a half install on a Five Star 13 SEER 2.5 ton air conditioner. I cycled and monitored the system. Operating normally at this time.

Justin S.

Justin S. Job Checkin

I completed an estimate for a Five Star 2.5 ton electric furnace and a Carrier 14 SEER 2.5 ton heat pump. Along with the estimate is a free 1 year scheduled maintenance program.


Justin S.

Justin S. Job Checkin

I completed a half install on a Five Star 13 SEER 2.5 ton air conditioner. Included with this install is a 1 year scheduled maintenance agreement. Cycled and monitored the system. Operating normally at this time.


Justin S.

Justin S. Job Checkin

I completed a diagnostic. On inspection of vent system and connecters, everything is connected properly. I don't see any rusting or deterioration. Roof cap is in place, and I don't see anything with this venting that would cause any unsafe conditions.

I completed a diagnostic.  On inspection of vent system and connecters, everything is connected properly. I don't see any rusting or deterioration. Roof cap is in place, and I don't see anything with this venting that would cause any unsafe conditions.

Justin S.

Justin S. Job Checkin

I completed an estimate to replace a 24yr old Rudd AC unit. I recommended the client to replace the unit with a Five Star 13 SEER 2.5 Ton Air Conditioner for the size of their home and the amount of air that needs to be pushed through the home. Attached is a photo of the unit that needs replaced.

I completed an estimate to replace a 24yr old Rudd AC unit. I recommended the client to replace the unit with a Five Star 13 SEER 2.5 Ton Air Conditioner for the size of their home and the amount of air that needs to be pushed through the home. Attached is a photo of the unit that needs replaced.

Justin S.

Justin S. Job Checkin

I completed a diagnostic on a Goodman air conditioning unit. Found bad capacitor on 21 year old air conditioner. Customer states that air conditioner was running fine previously. I replaced the capacitor at his request and cycled system. Replaced filter and checked charge. Refrigerant charge is running at a 21° superheat. System was running upon my departure.

I completed a diagnostic on a Goodman air conditioning unit. Found bad capacitor on 21 year old air conditioner. Customer states that air conditioner was running fine previously. I replaced the capacitor at his request and cycled system. Replaced filter and checked charge. Refrigerant charge is running at a 21° superheat. System was running upon my departure.

Stephanie G.

Stephanie G. Job Checkin

I completed diagnostic on Goodman Gas Furnace. I determined circuit control board and ignitor need to be replaced. I gave customer Estimates for repair and replacement. Customer plans to wait until next heating season to decide.

I completed diagnostic on Goodman Gas Furnace. I determined circuit control board and ignitor need to be replaced. I gave customer Estimates for repair and replacement. Customer plans to wait until next heating season to decide.

Josh A.

Josh A. Job Checkin

I preformed a leak search on an Air Conditioner. I determined that the leak was in the air handler. Will need Braise Copper line to fix the leak. replacement scheduled for following day

I preformed a leak search on an Air Conditioner. I determined that the leak was in the air handler. Will need Braise Copper line to fix the leak. replacement scheduled for following day

Tara L.

Tara L. Job Checkin

I performed a diagnostic on a 1999 ICP furnace. The board is fried due to the basement being flooded. The customer will be replacing the furnace in the future.

I performed a diagnostic on a 1999 ICP furnace. The board is fried due to the basement being flooded. The customer will be replacing the furnace in the future.

Bella M.

Bella M. Job Checkin

I performed a diagnostic on a Kenmore gas furnace that did not have heat. The inducer motor would not spin and I was unable to spin it by hand. I removed the motor and found a large bird wrapped around the motor and was unable to be removed. The customer will replace the motor and assembly.


Bella M.

Bella M. Job Checkin

I performed a diagnostic on a Kenmore gas furnace that did not have heat. The inducer motor would not spin and I was unable to spin it by hand. I removed the motor and found a large bird wrapped around the motor and was unable to be removed. The customer will replace the motor and assembly.


Justin S.

Justin S. Job Checkin

I performed a callback on a service of an Aprilaire humidifier installation due to leakage. There was no wet switch installed underneath this unit so nothing shut the unit off when it started leaking. We will replace the existing humidifier with a small bypass type humidifier and add a wet switch. We will also have a contractor make repairs to the drywall that was damaged.

I performed a callback on a service of an Aprilaire humidifier installation due to leakage. There was no wet switch installed underneath this unit so nothing shut the unit off when it started leaking. We will replace the existing humidifier with a small bypass type humidifier and add a wet switch. We will also have a contractor make repairs to the drywall that was damaged.

Chris  A.

Chris A. Job Checkin

I found the system overheating due to a clogged evap coil. Due to the age of the system, I recommended the customer replace the system.

I found the system overheating due to a clogged evap coil. Due to the age of the system, I recommended the customer replace the system.

Josh A.

Josh A. Job Checkin

Customer advised that sense the recent tuneup there new system has failed to come back on. System was already turned on at stat and no air blowing out of the vents. Furnace was showing that it was locked out. Reset power to system and restarted. System ignited and began heating the house Problem was caused at the end of the tuneup and testing of equipment, on the variable speed system while conducting routine maintenance the door safety is bypassed. If you release the door safety before the system shuts down on its own, or blower speed slows, the sudden stoppage of equipment will cause a limit to trip. Recreated the same issue multiple times while testing this system System will not restart until the limit is reset. Previous tech would not have known this however needs verified that the system is operational when tuneup is completed.

Customer advised that sense the recent tuneup there new system has failed to come back on. System was already turned on at stat and no air blowing out of the vents. Furnace was showing that it was locked out. Reset power to system and restarted. System ignited and began heating the house Problem was caused at the end of the tuneup and testing of equipment, on the variable speed system while conducting routine maintenance the door safety is bypassed. If you release the door safety before the system shuts down on its own, or blower speed slows, the sudden stoppage of equipment will cause a limit to trip. Recreated the same issue multiple times while testing this system System will not restart until the limit is reset. Previous tech would not have known this however needs verified that the system is operational when tuneup is completed.