Replaced a heat strip kit on an Amana heat pump system. System system operations. System operations ok at this time.


Alexander D.

Alexander D. Job Checkin

Remove existing equipment and haul away. Install Rheem 3.0 Ton, 15 Seer, 80% Furnace (1 Stage). Reconnect condensate lines and verify flow to the exterior. Install new furnace stand in garage. Chemically flush refrigerant lines and pressure test for new AC installation. Install new electrical dis-connect at condenser with properly sized fuses and weather tight flexible whip. Install new AC pad. Remove registers, manually seal boots to drywall and install existing registers. Install Honeywell T6 Thermastat. install new 30 x 14 high flow Grille. Install new MERV 13 filter tray and filter. HERS certification includes third party duct pressure test. Installation includes equipment, material, labor, all required testing, taxes and permits. Installation total $ 8,426.00 Net cost - $8,426.00


Miguel R.

Miguel R. Job Checkin

Performed diagnostic on 13 year old York gas furnace located in closet. Found a failed hot surface igniter that was cracked in half. Replaced hot surface igniter and cycled the heat. System ran for 10 mins without any issues. System is operational and heating at this time


Kris D.

Kris D. Job Checkin

Gave price for Rheem 7500 special


Chuc N.

Chuc N. Job Checkin

Arrived to home for a heat maintenance and ductwork inspection under home due to damaged ductwork from skunk. Couldn’t do either because the skunk is still under home and homeowner doesn’t want the system running until ductwork under home is replaced. Homeowner will give us a call when the skunk situation is taken care and aired out to schedule us to replace 3 duct runs in crawl space in kitchen. Also need to reschedule the maintenance after the ductwork is replaced.


Chuc N.

Chuc N. Job Checkin

Performed a diagnostic on an Amana heat pump. Found burnt fuses on air handler due to bad heat strips. Need to order part and reschedule when part comes in.


Chris M.

Chris M. Job Checkin

Removed dirty 16x25x5 Merv 16 filters and installed new ones for both systems.


Matt B.

Matt B. Job Checkin

Went over insulation estimate.


Chris L.

Chris L. Job Checkin

Removed hard pipe and elbows in bypass duct. Added one complete box of flex on each side. Changed out 14” motorized damper feeding zone 1. Checked wiring and tested system to confirm function. Zone board appears to be functioning properly, aside from a blinking purge LED that denotes a lack of DATS sensor. There was never one installed. There is also a 5” duct running from the zone feeding the kitchen and dining room that actually runs back into the section of zone 2 and into a small bathroom. This duct is probably 40’+ long. We need to send out the drywall guy to repair damage around attic access. This is a plaster wall and ceiling, notsheetrock.


Bradley M.

Bradley M. Job Checkin

Upon arrival system not operational; tripping on high limit after 10 minutes. Had 93 degree air coming back through the return from the Barometric bypass. Found one return duct pinched around joist. Also found zone 1 damper motor stuck closed causing higher static pressure and more heat gain in bypass. Opened stuck zone damper. Adjusted 2 return ducts for better airflow, increased CFM from 1480 to 1930. Return air temp. Now 82 degrees. System is currently operational. Disconnected both zone motors for temporary operation. Need to remove bypass. Replace zone board and damper motors.


Phong T.

Phong T. Job Checkin

Found furnace kept shutting off on high stage after 15 mins of runtime giving error code of High limit open. All wirings were in proper position at equipment, tstat, and zone board. Gas pressure were within spec, static was well below .5 inches of w.c. Tested return bypass damper closed and open and system still persist. Previous system did exact same thing, will go over with management tomorrow and get back with customer ASAP.


Kris D.

Kris D. Job Checkin

Replace existing single stage gas furnace with a Trane High Efficiency Two Stage Furnace. Install Trane Clean Effects Electronic Air Cleaner. Install second Trane Clean Effects Electronic Air Cleaner on other system. Installation includes: Installation by HUFT Journeyman employees, all Comfort Guarantees, remove and dispose of existing equipment, Title 24 HERS certification with a third party including duct leakage test, gas flex with ball type shut off valve, labor, material, taxes and permits. Trane: S9V2C100U5PSBB. 96% AFUE Warranty: 10 Year Parts, Lifetime H/E, 2 Year Labor. Project Cost: $12,074 INSTALLATION IS SET FOR 11/10/20


Andre B.

Andre B. Job Checkin

Performed heating maintenance for both Linux dual fuel systems. Checked all safeties and connections. Checked filters. Washed both outdoor units. Systems are operational at this time. Did not have Merv 16 filter‘s at this time, will have to order filters and reschedule for return visit at a later date.


Phong T.

Phong T. Job Checkin

Performed Heating maintenances on both furnaces. Merv 16 filter is still good today, will need to be change next visit 16x25x5. Cleaned flame sensor, vacuumed blower compartment, inspected Gas line, Gas pressure were within spec, cleared hoses and drain lines, all electrical wires and components were within spec and both systems are operating properly. Signed up on Superhero club membership for both systems today.


Glenn R.

Glenn R. Job Checkin

Installing new Trane 2 stage furnace.